Yu Zhao

Yu Zhao

Auto-generated profile, based on publicly available information

Yu Zhao

Vascular Surgery Department, The First Affiliated Hospital of Chongqing Medical University, Chongqing Medical University, Chongqing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2023 in Clinical Journal of the American Society of Nephrology
Verified
Journal Article
Open access
YZYiping Zhao
Yiping Zhao
PWPei Wang
Pei Wang
YWYuzhu Wang
Yuzhu Wang
LZLihong Zhang
Lihong Zhang
YZYu Zhao
Yu Zhao
LZLan Zhang
Lan Zhang
Background: The aim of this study was to evaluate the efficacy and safety of paclitaxel-coated balloons (AcoArt Orchid) in treating dysfunctional arteriovenous fistulae. Methods: The drug-eluting balloon for arteriovenous (AV) fistula in China trial was a prospective, multicenter, randomized controlled study. Patients who had ≥50% venous stenosis of the AV fistula and symptoms indicating significant hemodynamic changes were included. After successful predilation with a high-pressure balloon (residual stenosis ≤30%), patients were randomized 1:1 to either a paclitaxel-coated balloon or an uncoated control balloon. The primary efficacy outcome was assessed at 6 months, and safety assessment was conducted within 30 days of the procedure. The 12-month results were also analyzed. Results: The study included 244 patients, equally distributed between the two groups. The primary target lesion patency was 91% (106/116) for the drug-coated balloon (DCB) group and 67% (79/118) for the plain balloon catheter group, representing a difference of 24.63% (95% confidence interval, 14.68 to 34.58; P < 0.001). The secondary efficacy end point was primary target lesion patency at 12 months, which was 66% (74/112) for the DCB group and 46% (52/112) for the plain balloon catheter group (95% confidence interval, 6.57 to 32.08; P = 0.004). The mean number of reinterventions per patient to maintain target lesion patency during the 12 months after the index procedure was 0.39 (48/122) in the DCB group and 0.77 (94/122) in the plain balloon catheter group (P = 0.001). The primary safety end point did not differ between groups (P = 0.25). Conclusions: AcoArt Orchid DCB showed better primary patency rates compared with plain balloon angioplasty for treating stenotic lesions in dysfunctional hemodialysis AV fistulae at 6 and 12 months. It required fewer repeated interventions and had comparable safety in 1 year. Clinical Trial registry name and registration number: AcoArt III/Arterio-venous Fistula in China, NCT03366727.