Luke D. J. Thomson

Luke D. J. Thomson

Auto-generated profile, based on publicly available information

Luke D. J. Thomson

Department of Physiology, Biomedical Discovery Institute, Monash University, Melbourne, VIC, Australia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Annals of the American Thoracic Society
Verified
Journal Article
Closed access
EBElliot J. Brooker
Elliot J. Brooker
SLShane Landry
Shane Landry
LTLuke D. J. Thomson
Luke D. J. Thomson
GHGarun S. Hamilton
Garun S. Hamilton
PGPedro R. Genta
Pedro R. Genta
BEBradley Edwards
Bradley Edwards
Rationale: With up to 40% of individuals with either insomnia or obstructive sleep apnea (OSA) demonstrating clinically significant symptoms of the other disorder, the high degree of comorbidity among the two most common sleep disorders suggests a bidirectional relationship and/or shared underpinnings. Although the presence of insomnia disorder is believed to influence the underlying pathophysiology of OSA, this influence is yet to be examined directly. Objectives: To investigate whether the four OSA endotypes (upper airway collapsibility, muscle compensation, loop gain, and the arousal threshold) are different in patients with OSA with and without comorbid insomnia disorder. Methods: Using the ventilatory flow pattern captured from routine polysomnography, the four OSA endotypes were measured in 34 patients with OSA who met the diagnostic criteria for insomnia disorder (COMISA) and 34 patients with OSA without insomnia (OSA only). Patients demonstrated mild-to-severe OSA (apnea–hypopnea index, 25.8 ± 2.0 events/h) and were individually matched according to age (50.2 ± 1.5 yr), sex (42 male: 26 female), and body mass index (29.3 ± 0.6 kg/m2). Results: Compared with patients with OSA without comorbid insomnia, patients with COMISA demonstrated significantly lower respiratory arousal thresholds (128.9 [118.1 to 137.1] vs. 147.7 [132.3 to 165.0] % eupneic ventilation (V̇eupnea); U = 261; 95% confidence interval [CI], −38.3 to −13.9; d = 1.1; P < 0.001), less collapsible upper airways (88.2 [85.5 to 94.6] vs. 72.9 [64.7 to 79.2] % V̇eupnea; U = 1081; 95% CI, 14.0 to 26.7; d = 2.3; P < 0.001), and more stable ventilatory control (i.e., lower loop gain: 0.51 [0.44 to 0.56] vs. 0.58 [0.49 to 0.70]; U = 402; 95% CI, −0.2 to −0.01; d = 0.05; P = 0.03). Muscle compensation was similar between groups. Moderated linear regression revealed that the arousal threshold moderated the relationship between collapsibility and OSA severity in patients with COMISA but not in patients with OSA only. Conclusions: A low arousal threshold is an overrepresented endotypic trait in individuals with COMISA and may exhibit a greater relative contribution to OSA pathogenesis in these patients. Contrastingly, the prevalence of a highly collapsible upper airway in COMISA was low, suggesting that anatomical predisposition may contribute less to OSA development in COMISA. Based on our findings, we theorize that conditioned hyperarousal perpetuating insomnia may translate to a reduced arousal threshold to respiratory events, thereby increasing the risk or severity of OSA. Therapies that target increased nocturnal hyperarousal (e.g., through cognitive behavior therapy for insomnia) may be effective in individuals with COMISA. Clinical trial registered with the Australian and New Zealand Clinical Trial Registry (ACTRN12616000586415).

21 May 2022 in Respirology
Verified
Journal Article
Open access
AWAi‐Ming Wong
Ai‐Ming Wong
SLShane Landry
Shane Landry
SJSimon A Joosten
Simon A Joosten
LTLuke D. J. Thomson
Luke D. J. Thomson
ATAnthony Turton
Anthony Turton
BEBradley Edwards
Bradley Edwards
Background and objective: Upper airway surgery for obstructive sleep apnoea (OSA) is an alternative treatment for patients who are intolerant of continuous positive airway pressure (CPAP). However, upper airway surgery has variable treatment efficacy with no reliable predictors of response. While we now know that there are several endotypes contributing to OSA (i.e., upper airway collapsibility, airway muscle response/compensation, respiratory arousal threshold and loop gain), no study to date has examined: (i) how upper airway surgery affects all four OSA endotypes, (ii) whether knowledge of baseline OSA endotypes predicts response to surgery and (iii) whether there are any differences when OSA endotypes are measured using the CPAP dial‐down or clinical polysomnographic (PSG) methods.Methods: We prospectively studied 23 OSA patients before and ≥3 months after multilevel upper airway surgery. Participants underwent clinical and research PSG to measure OSA severity (apnoea–hypopnoea index [AHI]) and endotypes (measured in supine non‐rapid eye movement [NREM]). Values are presented as mean ± SD or median (interquartile range).Results: Surgery reduced the AHITotal (38.7 [23.4 to 79.2] vs. 22.0 [13.3 to 53.5] events/h; p = 0.009). There were no significant changes in OSA endotypes, however, large but variable improvements in collapsibility were observed (CPAP dial‐down method: ∆1.9 ± 4.9 L/min, p = 0.09, n = 21; PSG method: ∆3.4 [−2.8 to 49.0]%Veupnoea, p = 0.06, n = 20). Improvement in collapsibility strongly correlated with improvement in AHI (%∆AHISupineNREM vs. ∆collapsibility: p < 0.005; R2 = 0.46–0.48). None of the baseline OSA endotypes predicted response to surgery.Conclusion: Surgery unpredictably alters upper airway collapsibility but does not alter the non‐anatomical endotypes. There are no baseline predictors of response to surgery.

27 March 2023 in Chest
Verified
Journal Article
Closed access
SLShane Landry
Shane Landry
DMDwayne L Mann
Dwayne L Mann
RBRichard Beare
Richard Beare
RMRichard McIntyre
Richard McIntyre
CBCaroline Beatty
Caroline Beatty
BEBradley A. Edwards
Bradley A. Edwards

1 April 2020 in Annals of the American Thoracic Society
Verified
Journal Article
Closed access
SLShane Landry
Shane Landry
SJSimon A. Joosten
Simon A. Joosten
LTLuke D. J. Thomson
Luke D. J. Thomson
ATAnthony Turton
Anthony Turton
AWAi-Ming Wong
Ai-Ming Wong
BEBradley Edwards
Bradley Edwards
Rationale: Unstable ventilatory control (high loop gain) is a causal factor in the development of obstructive sleep apnea. Methods for quantifying loop gain using polysomnography have been developed that predict favorable responses to upper airway surgery. However, this method is reliant on respiratory event scoring and hence may be affected by hypopnea scoring criteria. Objectives: To determine to what extent differences in hypopnea scoring influence loop gain measurement. Methods: We performed a retrospective analysis of 46 polysomnograms before and after upper airway surgery. Polysomnograms were rescored according to three different American Academy of Sleep Medicine hypopnea definitions (2007Alternative, 2012Recommended, and 2012Acceptable criteria). Loop gain and apnea–hypopnea indexes (AHIs) were compared between criteria using linear regression and Bland-Altman limits of agreement (LOA). Responders to surgery were classified by a 50% or greater reduction in AHI and AHIpostsurgery less than 10 events per hour. Responders were determined separately for each American Academy of Sleep Medicine criterion. Receiver operating characteristic curve analysis predicting surgical outcome was performed for each loop gain measurement derived from each criterion. Results: A near-perfect agreement was found between loop gains derived using the 2007Alternative and 2012Recommended criteria (r2 = 0.99; bias = −0.003; LOA, −0.016 to 0.010). Greater variability was found for 2012Acceptable compared to the 2007Alternative (r2 = 0.70; bias = −0.015; LOA, −0.099 to 0.070) and 2012Recommended (r2 = 0.69; bias = +0.018; LOA, −0.068 to 0.104) criteria. Both 2007Alternative and 2012Recommended loop gains significantly predicted surgical response with similar areas under the curve (AUCs; 2007Alternative AUC = 0.86 [95% confidence interval (CI), 0.75–0.97]; 2012Recommended AUC = 0.84 [95% CI, 0.71–0.97]). 2012Acceptable loop gains were a poor predictor of surgical response (AUC = 0.62 [95% CI, 0.43–0.80]). Conclusions: Loop gain measured noninvasively by polysomnography can be influenced by respiratory event scoring. We recommend caution when using the 2012Acceptable criteria with this method, because such findings may not be directly generalizable to other loop gain values derived from other scoring criteria.

3 August 2020 in Respirology
Verified
Journal Article
Open access
PDF file
SLShane Landry
Shane Landry
DMDwayne L Mann
Dwayne L Mann
LDLee Djumas
Lee Djumas
LMLudovico Messineo
Ludovico Messineo
PTPhilip I. Terrill
Philip I. Terrill
SJSimon A Joosten
Simon A Joosten
Click on the article title to read more.

1 November 2020 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
LTLuke D. J. Thomson
Luke D. J. Thomson
SLShane Landry
Shane Landry
RSRebecca Singleton
Rebecca Singleton
AWAi-Ming Wong
Ai-Ming Wong
SJSimon A. Joosten
Simon A. Joosten
BEBradley Edwards
Bradley Edwards