Mirko Gamba

Mirko Gamba

Auto-generated profile, based on publicly available information

Mirko Gamba

Department of Aerospace Engineering, University of Michigan, Ann Arbor, MI 48109, USA

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2015 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
MGMirko Gamba
Mirko Gamba
MMM. Godfrey Mungal
M. Godfrey Mungal
We have investigated the properties of transverse sonic hydrogen jets in high-temperature supersonic crossflow at jet-to-crossflow momentum flux ratios $J$ between 0.3 and 5.0. The crossflow was held fixed at a Mach number of 2.4, 1400 K and 40 kPa. Schlieren and $\text{OH}^{\ast }$ chemiluminescence imaging were used to investigate the global flame structure, penetration and ignition points; $\text{OH}$ planar laser-induced fluorescence imaging over several planes was used to investigate the instantaneous reaction zone. It is found that $J$ indirectly controls many of the combustion processes. Two regimes for low ( ${<}1$ ) and high ( ${>}3$ ) $J$ are identified. At low $J$ , the flame is lifted and stabilizes in the wake close to the wall possibly by autoignition after some partial premixing occurs; most of the heat release occurs at the wall in regions where $\text{OH}$ occurs over broad regions. At high $J$ , the flame is anchored at the upstream recirculation region and remains attached to the wall within the boundary layer where $\text{OH}$ remains distributed over broad regions; a strong reacting shear layer exists where the flame is organized in thin layers. Stabilization occurs in the upstream recirculation region that forms as a consequence of the strong interaction between the bow shock, the jet and the boundary layer. In general, this interaction – which indirectly depends on $J$ because it controls the jet penetration – dominates the fluid dynamic processes and thus stabilization. As a result, the flow field may be characterized by a flame structure characteristic of multiple interacting combustion regimes, from (non-premixed) flamelets to (partially premixed) distributed reaction zones, thus requiring a description based on a multi-regime combustion formulation.

17 February 2021 in Shock Waves
Verified
Journal Article
Closed access
PDF file
TST. Sato
T. Sato
FCF. Chacon
F. Chacon
MGM. Gamba
M. Gamba
VRV. Raman
V. Raman


15 December 2020 in Open Forum Infectious Diseases
Verified
Journal Article
Open access
PDF file
KWKrista R Wigginton
Krista R Wigginton
PAPeter J Arts
Peter J Arts
HCHerek L Clack
Herek L Clack
WFWilliam J Fitzsimmons
William J Fitzsimmons
MGMirko Gamba
Mirko Gamba
KKKeith S. Kaye
Keith S. Kaye
Due to unprecedented shortages in N95 filtering facepiece respirators, healthcare systems have explored N95 reprocessing. No single, full-scale reprocessing publication has reported an evaluation including multiple viruses, bacteria, and fungi along with respirator filtration and fit. We explored reprocessing methods using new 3M 1860 N95 respirators, including moist (50%–75% relative humidity [RH]) heat (80–82°C for 30 minutes), ethylene oxide (EtO), pulsed xenon UV-C (UV-PX), hydrogen peroxide gas plasma (HPGP), and hydrogen peroxide vapor (HPV). Respirator samples were analyzed using 4 viruses (MS2, phi6, influenza A virus [IAV], murine hepatitis virus [MHV)]), 3 bacteria (Escherichia coli, Staphylococcus aureus, Geobacillus stearothermophilus spores, and vegetative bacteria), and Aspergillus niger. Different application media were tested. Decontaminated respirators were evaluated for filtration integrity and fit. Heat with moderate RH most effectively inactivated virus, resulting in reductions of >6.6-log10 MS2, >6.7-log10 Phi6, >2.7-log10 MHV, and >3.9-log10 IAV and prokaryotes, except for G stearothermohphilus. Hydrogen peroxide vapor was moderately effective at inactivating tested viruses, resulting in 1.5- to >4-log10 observable inactivation. Staphylococcus aureus inactivation by HPV was limited. Filtration efficiency and proper fit were maintained after 5 cycles of heat with moderate RH and HPV. Although it was effective at decontamination, HPGP resulted in decreased filtration efficiency, and EtO treatment raised toxicity concerns. Observed virus inactivation varied depending upon the application media used. Both moist heat and HPV are scalable N95 reprocessing options because they achieve high levels of biological indicator inactivation while maintaining respirator fit and integrity.

1 January 2003 in JSME International Journal Series B
Verified
Journal Article
Open access
JHJohn Reid Howell
John Reid Howell
KDKyle Daun
Kyle Daun
HEHakan Erturk
Hakan Erturk
MGMirko Gamba
Mirko Gamba
MSMasoud Hosseini Sarvari
Masoud Hosseini Sarvari

3 June 2015 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
MGMirko Gamba
Mirko Gamba
VMVictor A. Miller
Victor A. Miller
MMM. Godfrey Mungal
M. Godfrey Mungal
RHRonald K. Hanson
Ronald K. Hanson