30 November 2015 in Applied Physics Letters
We are developing arrays of X-ray microcalorimeters on a 50-µm pitch that utilize transition-edge sensors as the sensor to measure the temperature rise when X-rays are absorbed. An array of this type of pixel has great potential for the study of point sources in future X-ray observatory missions. The pixels have gold absorbers with dimensions 45 × 45 × 4.2 µm3. We measured an energy resolution of 0.72 ± 0.03 eV full width at half maximum for the Al Kα complex in a subset of pixels within the array, which is the best resolution to date using a non-dispersive detector at this energy. We describe our characterization of this device including measurements of the heat capacity, thermal conductance to the heat bath, and the temperature and current sensitivity of the detector, and discuss its potential for improved performance.
23 April 2019 in Journal of Applied Physics
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.
16 June 2026 in Journal of Applied Physics
The resolving power of single-photon microcalorimeters for high-resolution x-ray spectroscopy has improved to the point that uncertainties in the energy calibration can limit their scientific capability. X-ray fluorescent lines have been the usual standard for calibrations, but they have intrinsic widths much broader than the current detector resolution. Since microcalorimeters respond to total energy deposited as heat, we have investigated the idea that five hundred 3 eV photons from an ultraviolet laser delivered in a pulse much shorter than the thermal integration time of the detectors should look the same as a single 1500 eV x-ray photon. We have illuminated devices that have 290 μm square gold absorbers, superconducting transition edge sensor thermometers, and about 1 eV FWHM (Full Width at Half Maximum) resolution with ∼100ns pulses from an ultraviolet laser. This produces combs of lines with 3 eV spacing and negligible intrinsic width that extends to at least 1500 eV. The accuracy of the line energies is limited only by our knowledge of the laser wavelength. Simultaneous illumination with oxygen and aluminum K fluorescent lines shows that the response to an x-ray photon is indistinguishable from the response to a burst of UV photons with the same total energy to better than 0.4 eV at 1500 eV, limited by our knowledge of the fluorescent energy distribution.