Britt B. S. L. Houwen

Britt B. S. L. Houwen

Auto-generated profile, based on publicly available information

Britt B. S. L. Houwen

Department of Gastroenterology and Hepatology, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2021 in Endoscopy
Verified
Journal Article
Closed access
PDF file
BHBritt B. S. L. Houwen
Britt B. S. L. Houwen
CHCesare Hassan
Cesare Hassan
VCVeerle M. H. Coupé
Veerle M. H. Coupé
MGMarjolein J. E. Greuter
Marjolein J. E. Greuter
YHYark Hazewinkel
Yark Hazewinkel
EDEvelien Dekker
Evelien Dekker
Background The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 – 5 mm).Methods A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds.Recommendation 1 In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm in the rectosigmoid. Histopathology is used as the gold standard.Level of agreement 95 %.Recommendation 2 In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm. Histopathology is used as the gold standard.Level of agreement 100 %.Conclusion The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.

9 January 2023 in Endoscopy
Verified
Journal Article
Open access
PDF file
BHBritt B. S. L. Houwen
Britt B. S. L. Houwen
YHYark Hazewinkel
Yark Hazewinkel
IGIoannis Giotis
Ioannis Giotis
JVJasper L. A. Vleugels
Jasper L. A. Vleugels
NMNahid S. Mostafavi
Nahid S. Mostafavi
PGPOLAR Study Group
POLAR Study Group
Background We aimed to compare the accuracy of the optical diagnosis of diminutive colorectal polyps, including sessile serrated lesions (SSLs), between a computer-aided diagnosis (CADx) system and endoscopists during real-time colonoscopy. Methods We developed the POLyp Artificial Recognition (POLAR) system, which was capable of performing real-time characterization of diminutive colorectal polyps. For pretraining, the Microsoft-COCO dataset with over 300 000 nonpolyp object images was used. For training, eight hospitals prospectively collected 2637 annotated images from 1339 polyps (i. e. publicly available online POLAR database). For clinical validation, POLAR was tested during colonoscopy in patients with a positive fecal immunochemical test (FIT), and compared with the performance of 20 endoscopists from eight hospitals. Endoscopists were blinded to the POLAR output. Primary outcome was the comparison of accuracy of the optical diagnosis of diminutive colorectal polyps between POLAR and endoscopists (neoplastic [adenomas and SSLs] versus non-neoplastic [hyperplastic polyps]). Histopathology served as the reference standard. Results During clinical validation, 423 diminutive polyps detected in 194 FIT-positive individuals were included for analysis (300 adenomas, 41 SSLs, 82 hyperplastic polyps). POLAR distinguished neoplastic from non-neoplastic lesions with 79 % accuracy, 89 % sensitivity, and 38 % specificity. The endoscopists achieved 83 % accuracy, 92 % sensitivity, and 44 % specificity. The optical diagnosis accuracy between POLAR and endoscopists was not significantly different (P = 0.10). The proportion of polyps in which POLAR was able to provide an optical diagnosis was 98 % (i. e. success rate). Conclusions We developed a CADx system that differentiated neoplastic from non-neoplastic diminutive polyps during endoscopy, with an accuracy comparable to that of screening endoscopists and near-perfect success rate.

1 August 2023 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
QBQuerijn Ne van Bokhorst
Querijn Ne van Bokhorst
BHBritt Bsl Houwen
Britt Bsl Houwen
YHYark Hazewinkel
Yark Hazewinkel
PFPaul Fockens
Paul Fockens
EDEvelien Dekker
Evelien Dekker
Colorectal cancer (CRC) is the third most commonly diagnosed malignancy and the second leading cause of cancer related-death in the world [1]. CRC develops from precancerous polyps through several (epi)genetic pathways [2]. Colonoscopy is considered the gold standard for detection and diagnosis of CRC and its precursor lesions [3] [4]. Moreover, colonoscopy provides opportunities for endoscopic resection of precancerous polyps, which is known to be effective to prevent CRC [5]. Despite reported benefits, colonoscopy outcomes may differ depending on quality of the endoscopist performing the procedure. Among others, this relates to differences in ability of endoscopists to accurately assess polyp characteristics such as location [6], size [7] [8] [9] [10] and morphology [11] [12] [13], as well as differences in their performance in predicting histological polyp features (e.g. histological subtype [14] [15] [16], grade of dysplasia [17] [18] [19], and, in case of suspected malignancy, presence of deep submucosal invasion [DSI] [20] [21] [22]). These polyp characteristics are essential to decide on the indication for resection and histopathological analysis [23] [24], appropriate resection method [25] [26] and appropriate surveillance interval [27] [28]. Hence, inaccurate endoscopic polyp assessment could lead to higher patient and economic burden due to unnecessary polyp resection and analysis, as well as suboptimal treatment and/or surveillance regimens. Over the last decade, artificial intelligence (AI) in biomedical science has received growing attention. AI can be defined as the simulation of human intelligence by computer systems [29]. Specific AI techniques such as machine learning can be used to make machines (computers) smarter through experience-based learning [30] [31]. Since computer systems can be trained with a large amount of high quality and expert-annotated data, they could possibly serve as an objective, real-time, expert-level second observer modality during colonoscopy procedures. This might provide opportunities to reduce interobserver variability and improve general polyp assessment accuracy. While evidence is currently scattered, we aimed to write a narrative review to provide a broad overview of current developments within the field of AI and computer science for computer-aided assessment of colorectal polyps. This includes assessment of polyp location, size, morphology and histology, including degree of dysplasia (low grade dysplasia [LGD] versus high grade dysplasia [HGD]) and, in case of suspected malignancy, invasion depth. Since computer-aided polyp detection concerns an already more thoroughly studied and evaluated topic [32] [33], developments within this field will not be addressed within this review. Received: 04 February 2023 Accepted after revision: 08 May 2023 Article published online: 16 August 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

3 December 2021 in Endoscopy
Verified
Journal Article
Closed access
PDF file
BHBritt B. S. L. Houwen
Britt B. S. L. Houwen
CHCesare Hassan
Cesare Hassan
YHYark Hazewinkel
Yark Hazewinkel
JVJasper L. A. Vleugels
Jasper L. A. Vleugels
MDMario Dinis-Ribeiro
Mario Dinis-Ribeiro
RBRaf Bisschops
Raf Bisschops
Publication Date: 03 December 2021 (online) © 2021. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

1 August 2023 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
QBQuerijn Ne van Bokhorst
Querijn Ne van Bokhorst
BHBritt Bsl Houwen
Britt Bsl Houwen
YHYark Hazewinkel
Yark Hazewinkel
PFPaul Fockens
Paul Fockens
EDEvelien Dekker
Evelien Dekker
In the above-mentioned article the previously missing abstract was added. This was corrected in the online version on 25.08.2023. Article published online: 24 August 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany