Hannah L. Nathan

Hannah L. Nathan

Auto-generated profile, based on publicly available information

Hannah L. Nathan

Department of Women and Children’s Health, King’s College London, London, UK

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2019 in PLOS Medicine
Verified
Journal Article
Open access
PDF file
LMLaura A Magee
Laura A Magee
SSSumedha Sharma
Sumedha Sharma
HNHannah L Nathan
Hannah L Nathan
OAOlalekan O Adetoro
Olalekan O Adetoro
MBMrutyunjaya B. Bellad
Mrutyunjaya B. Bellad
CGCLIP Study Group
CLIP Study Group
Most pregnancy hypertension estimates in less-developed countries are from cross-sectional hospital surveys and are considered overestimates. We estimated population-based rates by standardised methods in 27 intervention clusters of the Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomised trials. CLIP-eligible pregnant women identified in their homes or local primary health centres (2013–2017). Included here are women who had delivered by trial end and received a visit from a community health worker trained to provide supplementary hypertension-oriented care, including standardised blood pressure (BP) measurement. Hypertension (BP ≥ 140/90 mm Hg) was defined as chronic (first detected at <20 weeks gestation) or gestational (≥20 weeks); pre-eclampsia was gestational hypertension plus proteinuria or a pre-eclampsia-defining complication. A multi-level regression model compared hypertension rates and types between countries (p < 0.05 considered significant). In 28,420 pregnancies studied, women were usually young (median age 23–28 years), parous (53.7%–77.3%), with singletons (≥97.5%), and enrolled at a median gestational age of 10.4 (India) to 25.9 weeks (Mozambique). Basic education varied (22.8% in Pakistan to 57.9% in India). Pregnancy hypertension incidence was lower in Pakistan (9.3%) than India (10.3%), Mozambique (10.9%), or Nigeria (10.2%) (p = 0.001). Most hypertension was diastolic only (46.4% in India, 72.7% in Pakistan, 61.3% in Mozambique, and 63.3% in Nigeria). At first presentation with elevated BP, gestational hypertension was most common diagnosis (particularly in Mozambique [8.4%] versus India [6.9%], Pakistan [6.5%], and Nigeria [7.1%]; p < 0.001), followed by pre-eclampsia (India [3.8%], Nigeria [3.0%], Pakistan [2.4%], and Mozambique [2.3%]; p < 0.001) and chronic hypertension (especially in Mozambique [2.5%] and Nigeria [2.8%], compared with India [1.2%] and Pakistan [1.5%]; p < 0.001). Inclusion of additional diagnoses of hypertension and related complications, from household surveys or facility record review (unavailable in Nigeria), revealed higher hypertension incidence: 14.0% in India, 11.6% in Pakistan, and 16.8% in Mozambique; eclampsia was rare (<0.5%). Pregnancy hypertension is common in less-developed settings. Most women in this study presented with gestational hypertension amenable to surveillance and timed delivery to improve outcomes. This study is a secondary analysis of a clinical trial - ClinicalTrials.gov registration number NCT01911494.

1 February 2015 in Blood Pressure Monitoring
Verified
Journal Article
Closed access
HNHannah L. Nathan
Hannah L. Nathan
AGAnnemarie de Greeff
Annemarie de Greeff
NHNatasha L. Hezelgrave
Natasha L. Hezelgrave
LCLucy C. Chappell
Lucy C. Chappell
ASAndrew H. Shennan
Andrew H. Shennan
Objectives To assess the accuracy of the Microlife 3AS1-2 blood pressure device in pregnancy and pre-eclampsia in a low-resource setting. Methods Prospective validation according to the British Hypertension Society protocol. A total of 45 pregnant women were recruited from Kimberley Hospital (South Africa), of whom 15 had pre-eclampsia. Results The Microlife 3AS1-2 device achieved an overall B/A grade in pregnancy (including pre-eclampsia), passing the British Hypertension Society protocol requirements and achieving the International Organization for Standardization standard with a mean difference and SD of −3.8±7.3 and −1.5±6.2 mmHg for systolic and diastolic pressures, respectively. Conclusion The Microlife 3AS1-2 device can be recommended for use in pregnancy, including pre-eclampsia. In addition, it fulfils the requirements stipulated by the WHO for an automated blood pressure device suitable for use in a low-resource setting. This makes it the ideal device for antenatal clinics and primary healthcare facilities in low-income and middle-income countries.

18 April 2019 in Acta Obstetricia et Gynecologica Scandinavica
Verified
Journal Article
Open access
PDF file
HNHannah L. Nathan
Hannah L. Nathan
PSPaul Seed
Paul Seed
NHNatasha L. Hezelgrave
Natasha L. Hezelgrave
AGAnnemarie De Greeff
Annemarie De Greeff
ELElodie Lawley
Elodie Lawley
ASAndrew H. Shennan
Andrew H. Shennan
Introduction: Shock index (SI) is a predictor of hemodynamic compromise in obstetric patients. The SI threshold for action is not well understood. We aimed to evaluate SI thresholds as predictors of outcomes in obstetric patients.Material and methods: We undertook a prospective cohort study at three South African hospitals of women with postpartum hemorrhage (n = 283) or maternal sepsis (n = 126). The “first” and “worst” SI following diagnosis were recorded. SI was compared with conventional vital signs as predictors of outcomes. The performance of SI <.9, SI .9‐1.69 and SI ≥1.7 to predict outcomes (maternal death; Critical Care Unit admission; major procedure; hysterectomy) and hemorrhage‐specific outcomes (lowest hemoglobin <70 g/l; blood transfusion ≥4 IU) were evaluated.Results: “First” SI was one of two best performing vital signs for every outcome in postpartum hemorrhage and sepsis. In hemorrhage, risk of all outcomes increased with increasing “first” SI; for blood transfusion ≥4 IU odds ratio was 4.24 (95% confidence interval 1.25‐14.36) for SI ≥1.7 vs SI .9‐1.69. In sepsis, risk of all outcomes increased with increasing “worst” SI. Sensitivity, specificity, positive and negative predictive values of “first” SI <.9 vs SI ≥.9 for maternal death were 100.0%, 55.2%, 4.6% and 100.0%, respectively, in hemorrhage and 80.0%, 50.4%, 12.3% and 96.7%, respectively, in sepsis.Conclusions: The shock index was a consistent predictor of outcomes compared with conventional vital signs in postpartum hemorrhage and sepsis. SI <.9 performed well as a rule‐out test and SI .9‐1.69 and SI ≥1.7 indicated increased risk of all outcomes in both cohorts. These thresholds may alert to the need for urgent intervention and prevent maternal deaths.

5 January 2018 in Reproductive Health
Verified
Journal Article
Open access
PDF file
HNHannah L. Nathan
Hannah L. Nathan
HBHelena Boene
Helena Boene
KMKhatia Munguambe
Khatia Munguambe
ESEsperança Sevene
Esperança Sevene
DADavid Akeju
David Akeju
ASAndrew H. Shennan
Andrew H. Shennan
Vital signs measurement can identify pregnant and postpartum women who require urgent treatment or referral. In low-resource settings, healthcare workers have limited access to accurate vital signs measuring devices suitable for their environment and training. The CRADLE Vital Signs Alert (VSA) is a novel device measuring blood pressure and pulse that is accurate in pregnancy and designed for low-resource settings. Its traffic light early warning system alerts healthcare workers to the need for escalation of care for women with hypertension, haemorrhage or sepsis. This study evaluated the usability and acceptability of the CRADLE VSA device. Evaluation was conducted in community and primary care settings in India, Mozambique and Nigeria and tertiary hospitals in South Africa. Purposeful sampling was used to convene 155 interviews and six focus groups with healthcare workers using the device (n = 205) and pregnant women and their family members (n = 41). Interviews and focus groups were conducted in the local language and audio-recorded, transcribed and translated into English for analysis. Thematic analysis was undertaken using an a priori thematic framework, as well as an inductive approach. Most healthcare workers perceived the CRADLE device to be easy to use and accurate. The traffic lights early warning system was unanimously reported positively, giving healthcare workers confidence with decision-making and a sense of professionalism. However, a minority in South Africa described manual inflation as tiring, particularly when measuring vital signs in obese and hypertensive women (n = 4) and a few South African healthcare workers distrusted the device’s accuracy (n = 7). Unanimously, pregnant women liked the CRADLE device. The traffic light early warning system gave women and their families a better understanding of the importance of vital signs in pregnancy and during the postpartum period. The CRADLE device was well accepted by healthcare workers from a range of countries and levels of facility, including those with no previous vital signs measurement experience. The device motivated women to attend primary care and encouraged them to accept treatment and referral.

1 April 2018 in Pregnancy Hypertension
Verified
Journal Article
Open access
HNHannah L. Nathan
Hannah L. Nathan
PSPaul Seed
Paul Seed
NHNatasha L. Hezelgrave
Natasha L. Hezelgrave
AGAnnemarie De Greeff
Annemarie De Greeff
ELElodie Lawley
Elodie Lawley
ASAndrew H. Shennan
Andrew H. Shennan
To evaluate the association between blood pressure (BP) measurements and adverse outcomes in women with pre-eclampsia. A prospective cohort study of women with pre-eclampsia admitted to three South African tertiary facilities. BP was measured using the CRADLE Vital Signs Alert (VSA), incorporated with a traffic light early warning system; green: systolic BP <140 mmHg and diastolic BP <90 mmHg, yellow: systolic BP 140-159 and/or diastolic BP 90-109 mmHg (but neither is above the upper threshold), red: systolic BP ≥160 mmHg and/or diastolic BP ≥110 mmHg. Maternal: death, eclampsia, stroke, kidney injury; process measures: magnesium sulfate use, Critical Care Unit (CCU) admission; perinatal: stillbirth, neonatal death, preterm delivery. Of 1547 women with pre-eclampsia (including 42 twin pregnancies), 33.0% of women triggered a red light on admission and 78.6% at their highest BP. Severe hypertension and adverse outcomes were common across yellow and red categories. Comparing admission red to yellow lights, there was a significant increase in kidney injury (OR 1.74, CI 1.31-2.33, trend test p = .003), magnesium sulfate use (OR 3.40, CI 2.24-5.18, p < .001) and CCU admission (OR 1.50, CI 1.18-1.91, p < .001), but not for maternal death, eclampsia, extended perinatal death or preterm delivery. The CRADLE VSA, with integrated traffic light early warning system, can identify women who are hypertensive, at increased risk of severe pre-eclampsia complications and in need of escalation of care. Women who triggered a red light were at increased risk of kidney injury, magnesium sulfate use and CCU admission.

19 September 2018 in BMJ Innovations
Verified
Journal Article
Open access
PDF file
HNHannah L Nathan
Hannah L Nathan
NVNicola Vousden
Nicola Vousden
ELElodie Lawley
Elodie Lawley
AGAnnemarie de Greeff
Annemarie de Greeff
NHNatasha L Hezelgrave
Natasha L Hezelgrave
ASAndrew H Shennan
Andrew H Shennan
Objectives Haemorrhage, hypertension, sepsis and abortion complications (often from haemorrhage or sepsis) contribute to 60% of all maternal deaths. Each is associated with vital signs (blood pressure (BP) and pulse) abnormalities, and the majority of deaths are preventable through simple and timely intervention. This paper presents the development and evaluation of the CRADLE Vital Signs Alert (VSA), an accurate, low-cost and easy-to-use device measuring BP and pulse with an integrated traffic light early warning system. The VSA was designed to be used by all cadres of healthcare providers for pregnant women in low-resource settings with the aim to prevent avoidable maternal mortality and morbidity. Methods The development and the mixed-methods clinical evaluation of the VSA are described. Results Preliminary fieldwork identified that introduction of BP devices to rural clinics improved antenatal surveillance of BP in pregnant women. The aesthetics of the integrated traffic light system were developed through iterative qualitative evaluation. The traffic lights trigger according to evidence-based vital sign thresholds in hypertension and haemodynamic compromise from haemorrhage and sepsis. The VSA can be reliably used as an auscultatory device, as well as its primary semiautomated function, and is suitable as a self-monitor used by pregnant women. Conclusion The VSA is an accurate device incorporating an evidence-based traffic light early warning system. It is designed to ensure suitability for healthcare providers with limited training and may improve care for women in pregnancy, childbirth and in the postnatal period.