Seok Chang Ryu

Seok Chang Ryu

Auto-generated profile, based on publicly available information

Seok Chang Ryu

Ewha Womans University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
SCShengwei Chen
Shengwei Chen
SRSeok Chang Ryu
Seok Chang Ryu
In the past decades, auxetic structures have received great attention because of their unique properties and outstanding performance over the traditional materials. However, the inherent porosity significantly reduce the moduli of the structures, making auxetic structures inappropriate for load-bearing components. This paper introduces a rounded re-entrant honeycomb (RH) pattern, in which the rounded corners stiffen the traditional RH pattern by suppressing the hinging mechanism. Four design parameters were identified to define a rounded RH unit cell, and the effect of each of them on structure properties was numerically studied. The results demonstrated the extended tunable range of mechanical properties and the possibility of building lightweight and stiffer structures, as well as significantly improved tensile and shear moduli. It is also noticed that the Poisson’s ratio shifts towards positive as the radius of the rounded corner increases. Several design strategies were proposed for achieving different design goals. The proposed rounded RH pattern could be an alternative for the existing RH pattern design, especially in the applications requesting for the lightweight and rigid auxetic structure.

20 December 2017 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
SPShivanand Pattanshetti
Shivanand Pattanshetti
SRSeok Chang Ryu
Seok Chang Ryu
With the proliferation of successful minimally invasive surgical techniques, comes the challenge of shrinking the size of surgical instruments further to facilitate use in applications such as neurosurgery, pediatric surgery, and needle procedures. This paper introduces laser machined, multi-degree-of-freedom (DOF) hinge joints embedded on tubes, as a possible means to realize such miniature instruments without the need for any assembly. A method to design such a joint for an estimated range of motion was explored. The effects of design and machining parameters on the mechanical interference, range of motion, and joint dislocation were analyzed. The extent of interference between the moving parts of the joint can be used to predict the range of motion of the joint for rigid tubes and future design optimization. The total usable workspace was also estimated using kinematic principles for a joint in series and for two sets of orthogonal joints. Our work can open up avenues to a new class of miniature robotic medical devices with hinge joints and a usable channel for drug delivery.

9 October 2019 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
RKRohith Karthikeyan
Rohith Karthikeyan
KSKelly Sigmund
Kelly Sigmund
YPYong-Lae Park
Yong-Lae Park
SRSeok Chang Ryu
Seok Chang Ryu
This study proposes an optically sensorized force-sensing tendon for minimally invasive surgical instruments. The tendon is composed of a high strength, polarization maintaining (PM) optical fiber with Bragg sensors (FBGs) that negate the cross-sensitivity of conventional FBGs. The PM-FBG fiber is locally reinforced with high stiffness Kevlar that enhances its load carrying capacity while enabling higher curvatures in tendon routing. The composite tendon has a mean diameter of ∼268 μm which preserves the form-factor of instruments within this scope. Importantly, the tendons can improve the functionality of such tools by enabling local force and tissue-resistance estimation. This paper explores the performance of these sensorized tendons in terms of strength, stability, response under dynamic load, friction, and sensitivity as a force measuring tool within an 18 Ga articulate Nitinol (NiTi) cannula (a proxy for potential applications). Results reaffirm the potential of a bi-modal sensing and actuation component within instruments for robotic surgery.

1 January 2025 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
BCBenjamin Calmé
Benjamin Calmé
AMAdam Metcalf
Adam Metcalf
MBMichael Brockdorff
Michael Brockdorff
HJHaneul Jang
Haneul Jang
YCYoonsue Choi
Yoonsue Choi
PVPietro Valdastri
Pietro Valdastri
Magnetic Soft Continuum Robots (MSCR) are used in a wide variety of surgical interventions, including neurological, pancreatic, and cardiovascular procedures. To function effectively, these MSCRs require complex programmable magnetisation. However, they often suffer from limited manoeuvrability and imprecise positioning of the devices that carry them. Tendon-Driven Continuum Robots (TDCR) have the potential to address these issues. These navigation systems not only enable higher accuracy and precision but also offer the potential for remote control, thereby reducing clinicians' exposure to ionising radiation. Currently, MSCRs are deployed from manual flexible endoscopes without motion compensation, leading to uncertainty and trial-and-error insertion. In this study, the deployment of high aspect ratio MSCRs (60 mm long by 1.3 mm diameter) from a tendon-driven robot (25 cm long with a 2.8 mm diameter) is performed. By precisely positioning the deployment point, this paper evaluates the benefits of different magnetisation profiles. The comparison is carried out for a specific clinical scenario, assessing procedure time, the distance between the external permanent magnet (used for steering) and the MSCR, and the interaction force with the tissue. Clinical relevance is demonstrated through pancreatic and bile duct cannulation in a silicon phantom.

14 February 2019 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
SCShengwei Chen
Shengwei Chen
RKRohith Karthikeyan
Rohith Karthikeyan
SRSeok Chang Ryu
Seok Chang Ryu

21 April 2022 in IEEE Access
Verified
Journal Article
Open access
LQLuca Quagliato
Luca Quagliato
SRSeok Chang Ryu
Seok Chang Ryu
A finite element analysis (FEA) model was developed for investigating the design and the tissue interaction of actively steerable needles with a rotational tip joint in soft tissue, based on the coupled Eulerian-Lagrangian (CEL) mesh. The new model is algorithmically simple in that the proposed CEL strategy allows needle insertion simulations along non-predetermined paths in soft tissue without the re-mesh at every direction change of the needle tip. For the features, various steering motions can be simulated and studied for different needle designs in a simpler approach by changing the needle geometry and boundary conditions. The developed FEA model, using the thoroughly measured material properties, was validated for predicting insertion path and estimating the tissue interaction forces inside two different gelatin tissue phantoms. Further, using the validated model, the effect of tip geometry on tissue was briefly investigated. Given bevel angles, it was found that the ratio of tip length to the diameter dominates the tissue damage gradient. The results demonstrate that the proposed model effectively examines the steering and tissue insertion of actively steerable needles and investigates the tip design to minimize the tissue damage by the needle steering.