David L. Morgan

David L. Morgan

Auto-generated profile, based on publicly available information

David L. Morgan

Department of Electrical and Computer Systems Engineering, Monash University, Clayton, Victoria 3800, Australia

Research Focus & Metrics

Academic Career Length

50Years (1977-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2001 in The Journal of Physiology
Verified
Journal Article
Open access
PDF file
UPU. Proske
U. Proske
DMD. L. Morgan
D. L. Morgan
In eccentric exercise the contracting muscle is forcibly lengthened; in concentric exercise it shortens. While concentric contractions initiate movements, eccentric contractions slow or stop them. A unique feature of eccentric exercise is that untrained subjects become stiff and sore the day afterwards because of damage to muscle fibres. This review considers two possible initial events as responsible for the subsequent damage, damage to the excitation‐contraction coupling system and disruption at the level of the sarcomeres. Other changes seen after eccentric exercise, a fall in active tension, shift in optimum length for active tension, and rise in passive tension, are seen, on balance, to favour sarcomere disruption as the starting point for the damage. As well as damage to muscle fibres there is evidence of disturbance of muscle sense organs and of proprioception. A second period of exercise, a week after the first, produces much less damage. This is the result of an adaptation process. One proposed mechanism for the adaptation is an increase in sarcomere number in muscle fibres. This leads to a secondary shift in the muscle's optimum length for active tension. The ability of muscle to rapidly adapt following the damage from eccentric exercise raises the possibility of clinical applications of mild eccentric exercise, such as for protecting a muscle against more major injuries.

1 February 1990 in Biophysical Journal
Verified
Journal Article
Closed access
DMD.L. Morgan
D.L. Morgan

1 December 1993 in Progress in Neurobiology
Verified
Journal Article
Closed access
UPUwe Proske
Uwe Proske
DMDavid L. Morgan
David L. Morgan
JGJ.EDmund Gregory
J.EDmund Gregory

1 May 2001 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
CBCamilla L. Brockett
Camilla L. Brockett
DMDavid L. Morgan
David L. Morgan
UPUwe Proske
Uwe Proske
BROCKETT, C. L., D. L. MORGAN, and U. PROSKE. Human hamstring muscles adapt to eccentric exercise by changing optimum length. Med. Sci. Sports Exerc., Vol. 33, No. 5, 2001, pp. 783–790. Purpose: It is now established that unaccustomed eccentric exercise leads to muscle fiber damage and to delayed-onset muscle soreness (DOMS) in the days after exercise. However, a second bout of eccentric exercise, a week after the first, produces much less damage and soreness. The purpose of this study was to provide evidence from muscle mechanical properties of a proposed mechanism for this training effect in human hamstring muscles. Methods: The eccentric exercise involved 12 sets of 6 repetition “hamstring lowers,” performed on specially designed equipment. Hamstring angle-torque curves were constructed for each of 10 subjects (8 male and 2 female) while they performed maximum voluntary knee extension and flexion movements on an isokinetic dynamometer. Testing sessions were performed over the week before eccentric exercise, immediately post exercise, and daily, up to 8 d post exercise. Subject soreness ratings and leg girth measurements were also made post exercise. Six subjects performed a second bout of eccentric exercise, 8 d after the first, and measurements were continued up to 10 d beyond that. Results: There was a significant shift in the optimum angle for torque generation (Lo), to longer muscle lengths immediately post exercise (7.7° ± 2.1°, P < 0.01), indicating an increase in series compliance within some muscle fibers. Subsequent measurements showed increases in leg girth and some muscle soreness, suggesting muscle damage. The shift in Lo persisted, even after other injury parameters had returned to normal, consistent with a training effect. Subjects also showed fewer signs of muscle damage after the second exercise bout. Conclusion: This is the first study to show a sustained shift in optimum angle of human muscle as a protective strategy against injury from eccentric exercise. Implications of this work for athletes, particularly those prone to hamstring strains are discussed.

1 March 2004 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
CBCamilla L. Brockett
Camilla L. Brockett
DMDavid L. Morgan
David L. Morgan
UPUwe Proske
Uwe Proske
BROCKETT, C. L., D. L. MORGAN, and U. PROSKE. Predicting Hamstring Strain Injury in Elite Athletes. Med. Sci. Sports Exerc., Vol. 36, No. 3, pp. 379–387, 2004.IntroductionEccentric exercise, where the contracting muscle is lengthened, produces microscopic damage in muscle fibers, and sensati

1 August 1979 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
FJF J Julian
F J Julian
DMD L Morgan
D L Morgan