The EXtreme PREcision Spectrograph (EXPRES) is an optical fiber fed echelle instrument being designed and built at the Yale Exoplanet Laboratory to be installed on the 4.3-meter Discovery Channel Telescope operated by Lowell Observatory. The primary science driver for EXPRES is to detect Earth-like worlds around Sun-like stars. With this in mind, we are designing the spectrograph to have an instrumental precision of 15 cm/s so that the on-sky measurement precision (that includes modeling for RV noise from the star) can reach to better than 30 cm/s. This goal places challenging requirements on every aspect of the instrument development, including optomechanical design, environmental control, image stabilization, wavelength calibration, and data analysis. In this paper we describe our error budget, and instrument optomechanical design.

28 April 2020 in The Astronomical Journal
Verified
Journal Article
Closed access
RBRyan T. Blackman
Ryan T. Blackman
DFDebra A. Fischer
Debra A. Fischer
CJColby A. Jurgenson
Colby A. Jurgenson
DSDavid Sawyer
David Sawyer
TMTyler M. McCracken
Tyler M. McCracken
RPRafal Pawluczyk
Rafal Pawluczyk
The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s−1, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

2 April 2020 in The Astronomical Journal
Verified
Journal Article
Closed access
RPRyan R. Petersburg
Ryan R. Petersburg
J.J.M.冕JoelOng王加
J.M.冕JoelOng王加
LZLily L. Zhao
Lily L. Zhao
RBRyan T. Blackman
Ryan T. Blackman
JBJohn M. Brewer
John M. Brewer
DFDebra A. Fischer
Debra A. Fischer
The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s−1. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s−1 for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s−1.

1 February 2018 in The Astrophysical Journal
Verified
Journal Article
Closed access
RPRyan R. Petersburg
Ryan R. Petersburg
TMTyler M. McCracken
Tyler M. McCracken
DEDominic Eggerman
Dominic Eggerman
CJColby A. Jurgenson
Colby A. Jurgenson
DSDavid Sawyer
David Sawyer
DFDebra A. Fischer
Debra A. Fischer
Optical fiber modal noise is a limiting factor for high precision spectroscopy signal-to-noise in the near-infrared and visible. Unabated, especially when using highly coherent light sources for wavelength calibration, modal noise can induce radial velocity (RV) errors that hinder the discovery of low-mass (and potentially Earth-like) planets. Previous research in this field has found sufficient modal noise mitigation through the use of an integrating sphere, but this requires extremely bright light sources, a luxury not necessarily afforded by the next generation of high-resolution optical spectrographs. Otherwise, mechanical agitation, which “mixes” the fiber’s modal patterns and allows the noise to be averaged over minutes-long exposures, provides some noise reduction but the exact mechanism behind improvement in signal-to-noise and RV drift has not been fully explored or optimized by the community. Therefore, we have filled out the parameter space of modal noise agitation techniques in order to better understand agitation’s contribution to mitigating modal noise and to discover a better method for agitating fibers. We find that modal noise is best suppressed by the quasi-chaotic motion of two high-amplitude agitators oscillating with varying phase for fibers with large core diameters and low azimuthal symmetry. This work has subsequently influenced the design of a fiber agitator, to be installed with the EXtreme PREcision Spectrograph, that we estimate will reduce modal-noise-induced RV error to less than 3.2 cm s−1.

31 May 2016 in Journal of Astronomical Instrumentation
Verified
Journal Article
Closed access
CJColby Jurgenson
Colby Jurgenson
DFDebra Fischer
Debra Fischer
TMTyler McCracken
Tyler McCracken
DSDavid Sawyer
David Sawyer
MGMatt Giguere
Matt Giguere
GMGary Muller
Gary Muller

28 February 2017 in The Astrophysical Journal
Verified
Journal Article
Closed access
PDF file
RBRyan T. Blackman
Ryan T. Blackman
ASAndrew E. Szymkowiak
Andrew E. Szymkowiak
DFDebra A. Fischer
Debra A. Fischer
CJColby A. Jurgenson
Colby A. Jurgenson
Atmospheric effects on stellar radial velocity measurements for exoplanet discovery and characterization have not yet been fully investigated for extreme precision levels. We carry out calculations to determine the wavelength dependence of barycentric corrections across optical wavelengths, due to the ubiquitous variations in air mass during observations. We demonstrate that radial velocity errors of at least several cm s−1 can be incurred if the wavelength dependence is not included in the photon-weighted barycentric corrections. A minimum of four wavelength channels across optical spectra (380–680 nm) are required to account for this effect at the 10 cm s−1 level, with polynomial fits of the barycentric corrections applied to cover all wavelengths. Additional channels may be required in poor observing conditions or to avoid strong telluric absorption features. Furthermore, consistent flux sampling on the order of seconds throughout the observation is necessary to ensure that accurate photon weights are obtained. Finally, we describe how a multiple-channel exposure meter will be implemented in the EXtreme PREcision Spectrograph (EXPRES).