Department of Cardiology and Vascular Medicine, Faculty of Medicine, Universitas Indonesia/National Cardiovascular Centre Harapan Kita, Jakarta, Indonesia
Auto-generated profile, based on publicly available information
Rina Ariani
Department of Cardiology and Vascular Medicine, Faculty of Medicine, Universitas Indonesia/National Cardiovascular Centre Harapan Kita, Jakarta, Indonesia
According to the 2018 European Society of Cardiology guidelines, atrial septal defect (ASD) closure can be performed during pregnancy but is rarely indicated. In this case, we demonstrate the viability of percutaneous balloon-assisted ASD closure without fluoroscopy in a pregnant woman. A 23-year-old G3P2A0 woman who was 20 weeks pregnant had primary complaints of breathlessness [New York Heart Association functional class (NYHA fc) III and IV] for 1 week prior to admission. A transthoracic echocardiography showed a dilatation of the right atrium (RA), a dilated right ventricle, a dilated main pulmonary artery (28.1 mm), and an oval-shaped 22 × 33 mm-sized secundum ASD with a left-to-right shunt. Despite optimal pharmacological treatment, the NYHA fc persisted. Under transoesophageal echocardiography monitoring, we introduced a 40 mm Cera™ ASD Occluder (Lifetech, China) via the delivery sheath. The device was deployed in the usual position; however, despite numerous placement adjustments, the left atrium disc kept getting dislodged to the RA and could not engage correctly. Therefore, we decided to use a balloon-assisted approach using a sizing balloon of No. 34 mm. The device was successfully positioned, and a wiggle test was conducted to make sure that the device remained stable. The patient was able to give birth to the child normally several months later. Despite the fact that pregnant women with ASD receive a very low dose of radiation, it is nevertheless recommended to avoid radiation because this demographic is particularly vulnerable to it. It is possible to treat a large ASD in pregnant women with a successful balloon-assisted approach.
Introduction: Mitral valve repair (MVr) has been shown to achieve better outcomes than mitral valve replacement (MVR) in degenerative aetiology. However, that cannot be applied in rheumatic mitral valve disease. Therefore, this study aims to evaluate early and late clinical outcomes and mid-term survival in RHD compared to the non-RHD group and whether mitral valve repair is a better surgical approach in RHD patients. Methods: Patients who underwent mitral valve surgery with or without coronary artery bypass grafting were included in this study. All patients were divided into the RHD and non-RHD group by the type of mitral surgery performed. Early and late outcomes were evaluated, and mid-term cumulative survival was reported. Results: A total of 1382 patients post MV surgeries were included. The 30-day mortality was significantly higher in the RHD group compared to the non-RHD group (8.7% vs. 4.4%, p = 0.003). There was no difference in 30-day mortality between repair and replacement in each respective group. During follow-up (12–54 months), all-cause mortality between RHD and non-RHD groups (16.7% vs. 16.2%) was not different. In the RHD group, the survival of MVr was 85.6% (95% CI 82.0%–88.5%), and MVR was 78.3% (95% CI 75.8%–80.6%), p-value log rank 0.26 However, in the non-RHD group, patients who underwent MVr had better survival than MVR, with cumulative survival of 81.7% (95% CI 72.3%–88.2%) vs. 71.1% (95% CI 56.3%–81.7%) p-value log rank 0.007. Conclusion: Early mortality rate in rheumatic mitral valve surgery was higher than in non-rheumatic valve surgery. Although in rheumatic MV disease MV repair did not show a significant survival advantage over MV replacement, a trend towards more favourable survival in the repair group was observed.
1 January 2023 in Journal of the Hong Kong College of Cardiology
Aims: This study was conducted to assess the relationship of simple hematological parameters with the incidence of left atrial thrombus in rheumatic mitral stenosis in addition to conventional contributing factors. Methods: A cross-sectional analytical study was conducted in patients with significant rheumatic stenosis from 1 January 2018 to 31 July 2021. Thrombus evaluation was confirmed by transthoracic or transesophageal echocardiography. Lab tests were performed within 10 days prior to the echocardiographic evaluation. Subjects with significant mitral regurgitation will be excluded. Logistic regression analysis was done to evaluate the relationship between each variable to the presence of a thrombus. Results: Of the 318 subjects with significant rheumatic mitral stenosis included in the study, 102 patients (32%) had a thrombus in the left atrium. Of all the patients, it was known that subjects with atrial fibrillation rhythm as much as 63.8% and sinus rhythm 36.2%. Atrial fibrillation rhythm (OR 2.39; 95% CI 1.10-5.20, p = 0.028), left ventricular ejection fraction ≥56.68 % (OR 0.42; 95% CI 0.23 - 0.77, p = 0.005), TAPSE ≥18.10 mm (OR 0.44; 95% CI 0.230 - 0.83, p = 0.011), and hematocrit ≥45.15% (OR 2.98; 95% CI 1.27 - 6.98, p = 0.012) are associated with left atrial thrombus. Conclusion: Increased hematocrit was significantly associated with the incidence of left atrial thrombus, which may have contributed to the statis and hypercoagulable state component of the Virchow’s triad.
Ascending Stanford type A aortic dissection carries a high morbidity and mortality. Proper identification of the proximal origin of the dissection and determination of concomitant aortic valve involvement significantly facilitate surgical repair which may improve survival. 2 Rapid imaging is necessary for the timely diagnosis of a potentially life-threatening condition. Transthoracic Echocardiography is highly accurate for the detection of acute aortic syndromes especially identify ascending aortic pathology such as type A aortic dissection. 3 We report the unusual case of 52-years old male who present atypical presentation of aortic dissection with unclear view of dissection by CT Angiography aorta, and diagnosed as Localized Stanford A Aortic dissection with supported data by echocardiography modality.
11 July 2024 in Journal of Asian Pacific Society of Cardiology
Background: AF substantially increases the risk of stroke. The most widely used risk prediction score for AF is CHA2DS2-VASC. Previous studies have mainly focused on its efficacy among patients with non-valvular AF. The few studies that have considered patients with valvular AF highlight the tool’s poor scoring accuracy. Objective: This study was conducted to evaluate the clinical factors and echocardiographic parameters related to the incidence of ischaemic stroke in anticoagulated evaluated heart valves, rheumatic or artificial (EHRA) type 1 valvular AF patients. Methods: We conducted a retrospective cohort study using data from the Indonesian Registry on Atrial Fibrillation (OneAF). Patients with EHRA type 1 valvular AF recorded in the registry from January 2015 to December 2019 were included in the study. Results: The incidence of ischaemic stroke was 17 (5.2%) out of 329 AF patients with mitral stenosis or mechanical prosthetic valves. A multivariate analysis showed that two clinical factors: hypertension (OR 5.59; 95% CI [1.93–16.15]; p=0.001) and estimated glomerular filtration rate (eGFR) ≤59 ml/min/m2 (OR 3.62; 95% CI [1.30–10.02]; p=0.013), were independently associated with the incidence of ischaemic stroke. No echocardiographic parameters were associated with the incidence of ischaemic stroke in this population. Conclusion: Hypertension and impaired renal function elevated the risk of ischaemic stroke in the patient population. Further research is necessary to determine the proper scoring system for predicting ischaemic stroke in this subgroup.