Edina Klein

Edina Klein

Auto-generated profile, based on publicly available information

Edina Klein

Institute of Technical Microbiology, Hamburg University of Technology, Hamburg, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
Yong HuYong Hu
Yong Hu
DMDavid Rehnlund Maibach
David Rehnlund Maibach
EKEdina Klein
Edina Klein
JGJohannes Gescher
Johannes Gescher
CNChristof Niemeyer
Christof Niemeyer

18 February 2023 in Microbial Biotechnology
Verified
Journal Article
Open access
EKEdina M. Klein
Edina M. Klein
MKMelanie T. Knoll
Melanie T. Knoll
JGJohannes Gescher
Johannes Gescher
Microbial electrochemical systems (MESs) are a highly versatile platform technology with a particular focus on power or energy production. Often, they are used in combination with substrate conversion (e.g., wastewater treatment) and production of value‐added compounds via electrode‐assisted fermentation. This rapidly evolving field has seen great improvements both technically and biologically, but this interdisciplinarity sometimes hampers overseeing strategies to increase process efficiency. In this review, we first briefly summarize the terminology of the technology and outline the biological background that is essential for understanding and thus improving MES technology. Thereafter, recent research on improvements at the biofilm–electrode interface will be summarized and discussed, distinguishing between biotic and abiotic approaches. The two approaches are then compared, and resulting future directions are discussed. This mini‐review therefore provides basic knowledge of MES technology and the underlying microbiology in general and reviews recent improvements at the bacteria–electrode interface.

15 January 2022 in Applied Microbiology and Biotechnology
Verified
Journal Article
Open access
PDF file
EKEdina Klein
Edina Klein
JWJanek Weiler
Janek Weiler
MWMichael Wagner
Michael Wagner
MČMinja Čelikić
Minja Čelikić
CNChristof Niemeyer
Christof Niemeyer
JGJohannes Gescher
Johannes Gescher
: Wastewater treatment using aerobic granular sludge has gained increasing interest due to its advantages compared to conventional activated sludge. The technology allows simultaneous removal of organic carbon, nitrogen, and phosphorus in a single reactor system and is independent of space-intensive settling tanks. However, due to the microscale, an analysis of processes and microbial population along the radius of granules is challenging. Here, we introduce a model system for aerobic granular sludge on a small scale by using a machine-assisted microfluidic cultivation platform. With an implemented logic module that controls solenoid valves, we realized alternating oxic hunger and anoxic feeding phases for the biofilms growing within. Sampling during ongoing anoxic cultivation directly from the cultivation channel was achieved with a robotic sampling device. Analysis of the biofilms was conducted using optical coherence tomography, fluorescence in situ hybridization, and amplicon sequencing. Using this setup, it was possible to significantly enrich the percentage of polyphosphate-accumulating organisms (PAO) belonging to the family Rhodocyclaceae in the community compared to the starting inoculum. With the aid of this miniature model system, it is now possible to investigate the influence of a multitude of process parameters in a highly parallel way to understand and efficiently optimize aerobic granular sludge-based wastewater treatment systems.Key points• Development of a microfluidic model to study EBPR.• Feast-famine regime enriches polyphosphate-accumulating organisms (PAOs).• Microfluidics replace sequencing batch reactors for aerobic granular sludge research.

5 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EKEdina Marlen Klein
Edina Marlen Klein
HHHannah Heintz
Hannah Heintz
RWRené Wurst
René Wurst
SSSimon Schuldt
Simon Schuldt
HHHendrik Hähl
Hendrik Hähl
JGJohannes Gescher
Johannes Gescher
Biofilm formation by Shewanella oneidensis has been extensively studied under oxic conditions; however, relatively little is known about biofilm formation under anoxic conditions and how biofilm architecture and composition can positively influence current generation in bioelectrochemical systems. In this study, we utilized a recently developed microfluidic biofilm analysis setup with automated 3D imaging to investigate the effects of extracellular electron acceptors and synthetic modifications to the extracellular polymeric matrix on biofilm formation. Our results with the wild type strain demonstrate robust biofilm formation even under anoxic conditions when fumarate is used as the electron acceptor. However, this pattern shifts when a graphite electrode is employed as the electron acceptor, resulting in biofilm formation falling below the detection limit of the optical coherence tomography imaging system. To manipulate biofilm formation, we aimed to express BpfG with a single amino acid substitution in the catalytic center (C116S) and to overexpress bpfA. Our analyses indicate that, under oxic conditions, overarching mechanisms predominantly influence biofilm development, rather than the specific mutations we investigated. Under anoxic conditions, the bpfG mutation led to a quantitative increase in biofilm formation, but both strains exhibited significant qualitative changes in biofilm architecture compared to the controls. When an anode was used as the sole electron acceptor, both the bpfA and bpfG mutations positively impacted mean current density, yielding a 1.8-fold increase for each mutation.

26 March 2020 in BIOspektrum
Verified
Journal Article
Open access
PDF file
PLPhillip Lemke
Phillip Lemke
EKEdina Klein
Edina Klein
JGJohannes Gescher
Johannes Gescher
CNChristof Niemeyer
Christof Niemeyer
Biofilms are the most abundant growth form of microorganisms in nature. To exploit these living systems for applications in biotechnology, we have developed a microfluidic cultivation platform with an integrated automatic sampling robot that enables the characterization of biofilms with high spatiotemporal resolution. Moreover, in situ imaging and anoxic or gas-consumption based cultivation can be applied. Biocatalytic productivity can be assessed using a spectrum of analytical technologies.

12 April 2026 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
LKLukas Kneuer
Lukas Kneuer
RWRené Wurst
René Wurst
CLChristian Jonas Lapp
Christian Jonas Lapp
NLNhật Quang Lê
Nhật Quang Lê
LKLeah Kobza
Leah Kobza
JGJohannes Gescher
Johannes Gescher
This work set out to establish an easily applicable system to improve a broad range of bioelectronic devices using the SpyTag-SpyCatcher crosslinking system together with one of the model organisms for extracellular electron transport, Shewanella oneidensis. Therefore, the surface-displayed c-type cytochrome MtrC was equipped with an accessible SpyTag and coupled to SpyCatcher-functionalized surfaces. A transposon screen followed by nanopore sequencing was conducted in order to identify integration positions which facilitate MtrC functionality while the SpyTag is surface accessible. Three integration positions (W314, Y417, T603) were chosen for further characterization. Expression of the MtrC-SpyTag constructs in a S. oneidensis strain lacking all outer membrane cytochromes restored the ability to reduce an extracellular electron acceptor. Two of the three strains reached reduction rates at the wildtype MtrC level proving that the integrated SpyTag does not hamper extracellular electron transfer. In vivo, all three constructs showed significantly better binding properties to SpyCatcher functionalized magnetic beads than the wildtype MtrC control. The two most promising candidates were coupled to conductive, magnetic gold nanoparticles and directed towards a screen-printed electrode showcasing how MtrC-SpyTag expression can improve bioelectronic devices. A significantly higher charge transfer compared to the wildtype control was reached in linear sweep voltammetry and chronoamperometry experiments. Moreover, a shift towards direct electron transfer was observed which reduces the problem of redox shuttle washout in flowthrough systems. Direct binding of the cells to SpyCatcher functionalized electrodes enabled robust current production even after thorough washing of the electrodes while control cells failed to produce current under these conditions. The versatile SpyCatcher toolbox can be used together with the here reported strains to eliminate bottlenecks in bioelectronics like poor biofilm formation or the production of an insulating extracellular polymer matrix.