Hui Zhou

Hui Zhou

Auto-generated profile, based on publicly available information

Hui Zhou

Institute of Biomedical and Health Engineering, and the Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 518055, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2017 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
BZBo Zhang
Bo Zhang
JGJunyi Gu
Junyi Gu
MQMing Qian
Ming Qian
LNLili Niu
Lili Niu
HZHui Zhou
Hui Zhou
Dhanjoo N. GhistaDhanjoo N. Ghista
Dhanjoo N. Ghista
This paper presents quantitative analysis of blood flow shear stress by measuring the carotid arterial wall shear stress (WSS) and the intima-media thickness (IMT) of experimental rabbits fed with high-fat feedstuff on a weekly basis in order to cause atherosclerosis. This study is based on establishing an atherosclerosis model of high-fat rabbits, and measuring the rabbits’ common carotid arterial WSS of the experimental group and control group on a weekly basis. Detailed analysis was performed by using WSS quantification. We have demonstrated small significant difference of rabbit carotid artery WSS between the experimental group and the control group (P<0.01) from the 1st week onwards, while the IMT of experimental group had larger differences from 5th week compared with the control group (P<0.05). Next, we have shown that with increasing blood lipids, the rabbit carotid artery shear stress decreases and the rabbit carotid artery IMT goes up. The decrease of shear stress appears before the start of IMT growth. Furthermore, our receiver operator characteristic (ROC) curve analysis showed that when the mean value of shear stress is 1.198 dyne/cm2, the rabbit common carotid atherosclerosis fatty streaks sensitivity is 89.8%, and the specificity is 81.3%. The area under the ROC curve is 0.9283. All these data goes to show that WSS decreasing to 1.198 dyne/cm2 can be used as an indicator that rabbit common carotid artery comes into the period of fibrous plaques. In conclusion, our study is able to find and confirm that the decrease of the arterial WSS can predict the occurrence of atherosclerosis earlier, and offer help for positive clinical intervention.

8 April 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HZHui Zhou
Hui Zhou
LMLong Meng
Long Meng
XXXiangxiang Xia
Xiangxiang Xia
ZLZhengrong Lin
Zhengrong Lin
WZWei Zhou
Wei Zhou
HZHairong Zheng
Hairong Zheng
Objective: Neuroinflammation contributes to the development and progression of Parkinson's disease (PD). The aim of this study was to examine whether ultrasound (US) stimulation of the subthalamic nucleus (STN) could suppress the neuroinflammation in a chronic PD mouse model induced by 1-Methyl-4-phenyl-1, 2, 3, 6-tetrahydropyridine (MPTP). Methods: A chronic PD mouse model was built by injections of 20mg/kg MPTP and 250 mg/kg probenecid at 3.5-day intervals for 5 weeks. Mice were randomized into control+sham, MPTP+sham and MPTP+STN+US group. For MPTP+STN+US group, ultrasound wave (3.8 MHz, 50% duty cycle, 1 kHz pulse repetition frequency, 30 min/day) was delivered to the STN the day after MPTP and probenecid injection (the early stage of PD progression). The rotarod test and pole test were performed to evaluate the behavioral changes after ultrasound treatment. Then, the activity of microglia and astrocyte were measured to evaluate the inflammation level in the brain. Results: Ultrasound stimulation improved the latency to falls in the rotarod test (p = 0.033) and decreased the climbing time in the pole test (p = 0.016) compared with MPTP+sham group. Moreover, ultrasound stimulation reduced the chronic inflammation response as shown in microglia (p = 0.007) and astrocyte (p = 0.032) activation. In addition, HE, Nissl and Tunel staining showed that no brain tissue injury was induced by US. Conclusion: These findings demonstrated that ultrasound stimulation could suppress neuroinflammation in PD mice. Significance: Transcranial ultrasound neuromodulation offers a novel approach for Parkinson's disease intervention, potentially through its anti-neuroinflammation functions.

12 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JZJunjie Zou
Junjie Zou
SYShasha Yi
Shasha Yi
LNLili Niu
Lili Niu
HZHui Zhou
Hui Zhou
ZLZhengrong Lin
Zhengrong Lin
LMLong Meng
Long Meng
Preliminary evidence suggests that low-intensity pulsed ultrasound (LIPUS) has neuroprotective effects on ischemic stroke, depression, and other conditions leading to neuronal cell death (e.g., Parkinson's disease). The purpose of this study was to investigate the neuroprotective effects of LIPUS in epileptic mice. Mice were made epileptic through kainic acid (KA) administration and then stimulated with LIPUS. The neuroprotective effect of ultrasound was evaluated by observing the latency, anxiety-like behavior, and levels of proteins related to inflammation, apoptosis, or signaling pathways. The safety of LIPUS was assessed by hematoxylin and eosin (H&E) and Nissl stainings. LIPUS prolonged the latency (Sham: 6.00 ± 0.26 days; 1-kHz pulse repetition frequency (PRF): 7.00 ± 0.31 days), improved the anxiety-like behavior, and inhibited the expression of inflammatory factors and apoptosis-related proteins. In addition, H&E and Nissl staining results confirmed that LIPUS did not damage the brain. These findings suggest that LIPUS has neuroprotective effects in mice with KA-induced epilepsy. LIPUS may offer a new therapeutic approach to epilepsy.

5 July 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
NPNa Pang
Na Pang
WMWen Meng
Wen Meng
YZYongsheng Zhong
Yongsheng Zhong
XLXiufang Liu
Xiufang Liu
ZLZhengrong Lin
Zhengrong Lin
LNLili Niu
Lili Niu
Body temperature plays a critical role in rehabilitation, and numerous studies proved that the regulation of body temperature contributes to the sensorimotor recovery of patients with brain diseases such as stroke. The hypothalamus plays a key role in thermoregulation. Ultrasound deep brain stimulation (UDBS) can noninvasively modulate deep brain nuclei and have potential applications in the treatment of Parkinson’s disease, Alzheimer’s disease, and depression, among others. The purpose of this study was to investigate whether ultrasound stimulation of the hypothalamus could regulate body temperature in free-moving mice. Results showed that thermoregulation was related to ultrasonic parameters (pulse repetition frequency (PRF), duty cycle, total time, and acoustic pressure). UDBS of the preoptic area of the anterior hypothalamus at 500 Hz PRF could significantly reduce body temperature ( $\text{T}\,\,= -0.25\,\,\pm \,\,0.073\,\,^{\circ }\text{C}$ at t = 5 min, $\text{T}\,\,= -0.51\,\,\pm \,\,0.19\,\,^{\circ }\text{C}$ at t = 10 min, $\text{T}\,\,= -0.84\,\,\pm \,\,0.27\,\,^{\circ }\text{C}$ at t = 15 min). Meanwhile, UDBS of the dorsomedial hypothalamus at 10 Hz PRF triggered a significant increase in body temperature ( $\text{T}\,\,=0.5\,\,\pm \,\,0.077\,\,^{\circ }\text{C}$ at t = 5 min, $\text{T}\,\,=1.16\,\,\pm \,\,0.23\,\,^{\circ }\text{C}$ at t = 10 min). These results suggest that UDBS, as a noninvasive neuromodulation tool, may play a key role in the future clinical treatment of malignant hyperthermia and hypothermia.

29 July 2017 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
HZHui Zhou
Hui Zhou
LMLong Meng
Long Meng
WZWei Zhou
Wei Zhou
LXLin Xin
Lin Xin
XXXiangxiang Xia
Xiangxiang Xia
LNLili Niu
Lili Niu
Studies have identified hemodynamic shear stress as an important determinant of endothelial function and atherosclerosis. In this study, we assess the influences of hemodynamic shear stress on carotid plaques. Carotid stenosis phantoms with three severity (30, 50, 70%) were made from 10% polyvinyl alcohol (PVA) cryogel. The phantoms were placed in a pulsatile flow loop with the same systolic/diastolic phase (35/65) and inlet flow rate (16 L/h). Ultrasonic particle imaging velocimetry (Echo PIV) and computational fluid dynamics (CFD) were used to calculate the velocity profile and shear stress distribution in the carotid stenosis phantoms. Inlet/outlet boundary conditions used in CFD were extracted from Echo PIV experiments to make sure that the results were comparable. Echo PIV and CFD results showed that velocity was largest in 70% than those in 30 and 50% at peak systole. Echo PIV results indicated that shear stress was larger in the upper wall and the surface of plaque than in the center of vessel. CFD results demonstrated that wall shear stress in the upstream was larger than in downstream of plaque. There was no significant difference in average velocity obtained by CFD and Echo PIV in 30% (p = 0.25). Velocities measured by CFD in 50% (93.01 cm/s) and in 70% (115.07 cm/s) were larger than those by Echo PIV in 50% (60.26 ± 5.36 cm/s) and in 70% (89.11 ± 7.21 cm/s). The results suggested that Echo PIV and CFD could obtain hemodynamic shear stress on carotid plaques. Higher WSS occurred in narrower arteries, and the shoulder of plaque bore higher WSS than in bottom part.