Department of Nuclear Energy, Institute of Nuclear Techniques, Faculty of Natural Sciences , Budapest University of Technology and Economics , Műegyetem rkp. 3, H-1111 Budapest , Hungary
Auto-generated profile, based on publicly available information
Attila Aszódi
Department of Nuclear Energy, Institute of Nuclear Techniques, Faculty of Natural Sciences , Budapest University of Technology and Economics , Műegyetem rkp. 3, H-1111 Budapest , Hungary
Electricity supply in European countries faces a number of challenges, such as achieving carbon neutrality, tackling rising prices, reducing dependence on fossil fuels, including fossil fuel imports. To achieve these goals, the electricity systems of all European countries will have to undergo major changes, while taking into account technical, environmental, economic and social objectives. Our simulations provide essential data for this transition by analyzing different power plant portfolios and electricity consumption scenarios. The analyses focus on the cooperation of nuclear power and weather-dependent renewables, and on the possible role that battery-based electricity storage can play in the Hungarian electricity system.
The flow conditions in nuclear reactor cores strongly influence heat transfer and thereby nuclear safety, requiring accurate experimental validation of numerical analysis, like computational fluid dynamics (CFD) models. particle image velocimetry (PIV) combined with the matching index of refraction (MIR) technique is widely used for such measurements; however, accurate refractive index matching remains a major challenge. This paper presents a novel image-based method and a compact measurement device for determining refractive index matching conditions. The method is based on comparing experimentally recorded distorted calibration images with simulated images generated using a ray-tracing optical model. The refractive index is obtained by minimizing the pixel-wise difference between measured and simulated images. Validation measurements were performed using water–glycerol solution and an FEP (Fluorinated ethylene propylene) tube, and the results were compared with a handheld refractometer. The method shows good linearity and achieves an expanded uncertainty of approximately ±2.34 × 10 −4 ( k = 2). The proposed approach determines refractive index matching directly under experimental conditions without requiring precise absolute refractive index measurements, thereby simplifying MIR-based PIV measurements.