Lucas V. A. Boersma

Lucas V. A. Boersma

Auto-generated profile, based on publicly available information

Lucas V. A. Boersma

Department of Cardiology, St. Antonius Hospital , Nieuwegein

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2023 in Circulation
Verified
Journal Article
Open access
AVAtul Verma
Atul Verma
DHDavid E. Haines
David E. Haines
LBLucas V. Boersma
Lucas V. Boersma
NSNitesh Sood
Nitesh Sood
ANAndrea Natale
Andrea Natale
DDDavid B. DeLurgio
David B. DeLurgio
Background: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. Methods: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. Results: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. Conclusions: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04198701.

27 January 2016 in European Heart Journal
Verified
Journal Article
Open access
PDF file
LBLucas V.A. Boersma
Lucas V.A. Boersma
BSBoris Schmidt
Boris Schmidt
TBTimothy Betts
Timothy Betts
HSHorst Sievert
Horst Sievert
CTCorrado Tamburino
Corrado Tamburino
MBMartin W. Bergmann
Martin W. Bergmann
Aims Left atrial appendage closure is a non-pharmacological alternative for stroke prevention in high-risk patients with non-valvular atrial fibrillation. The objective of the multicentre EWOLUTION registry was to obtain clinical data on procedural success and complications, and long-term patient outcomes, including bleeding and incidence of stroke/transient ischaemic attack (TIA). Here, we report on the peri-procedural outcomes of up to 30 days. Methods and results Baseline/implant data are available for 1021 subjects. Subjects in the study were at high risk of stroke (average CHADS 2 score: 2.8 ± 1.3, CHA 2 DS 2 -VASc: 4.5 ± 1.6) and moderate-to-high risk of bleeding (average HAS-BLED score: 2.3 ± 1.2). Almost half of the subjects (45.4%) had a history of TIA, ischaemic stroke, or haemorrhagic stroke; 62% of patients were deemed unsuitable for novel oral anticoagulant by their physician. The device was successfully deployed in 98.5% of patients with no flow or minimal residual flow achieved in 99.3% of implanted patients. Twenty-eight subjects experienced 31 serious adverse events (SAEs) within 1 day of the procedure. The overall 30-day mortality rate was 0.7%. The most common SAE occurring within 30 days of the procedure was major bleeding requiring transfusion. Incidence of SAEs within 30 days was significantly lower for subjects deemed to be ineligible for oral anticoagulation therapy (OAT) compared with those eligible for OAT (6.5 vs. 10.2%, P = 0.042). Conclusion Left atrial appendage closure with the WATCHMAN device has a high success rate in complete LAAC with low peri-procedural risk, even in a population with a higher risk of stroke and bleeding, and multiple co-morbidities. Improvement in implantation techniques has led to a reduction of peri-procedural complications previously limiting the net clinical benefit of the procedure.

1 September 2017 in Heart Rhythm
Verified
Journal Article
Open access
LBLucas V. Boersma
Lucas V. Boersma
HIHueseyin Ince
Hueseyin Ince
SKStephan Kische
Stephan Kische
EPEvgeny Pokushalov
Evgeny Pokushalov
TSThomas Schmitz
Thomas Schmitz
MBMartin W. Bergmann
Martin W. Bergmann
Left atrial appendage (LAA) occlusion with WATCHMAN has emerged as viable alternative to vitamin K antagonists in randomized controlled trials. EWOLUTION was designed to provide data in routine practice from a prospective multicenter registry. A total of 1025 patients scheduled for a WATCHMAN implant were prospectively and sequentially enrolled at 47 centers. Indication for LAA closure was based on European Society of Cardiology guidelines. Follow-up and transesophageal echocardiography (TEE) were performed per local practice. The baseline CHA2DS2-VASc score was 4.5 ± 1.6; the mean age was 73.4 ± 9 years; previous transient ischemic attack/ischemic stroke was present in 312 (30.5%), 155 (15.1%) had previous hemorrhagic stroke, and 320 (31.3%) had a history of major bleeding; and 750 (73%) were deemed unsuitable for oral anticoagulation therapy. WATCHMAN implant succeeded in 1005 (98.5%) of patients, without leaks >5 mm in 1002 (99.7%) with at least 1 TEE follow-up in 875 patients (87%). Antiplatelet therapy was used in 784 (83%), while vitamin K antagonists were used in only 75 (8%). At 1 year, mortality was 98 (9.8%), reflecting the advanced age and comorbidities in this population. Device thrombus was observed in 28 patients at routine TEE (3.7%) and was not correlated with the drug regimen (P = .14). Ischemic stroke rate was 1.1% (relative risk 84% vs estimated historical data); the major bleeding rate was 2.6% and was predominantly (2.3%) nonprocedure/device related. LAA closure with the WATCHMAN device has a high implant and sealing success. This method of stroke risk reduction appears to be safe and effective with an ischemic stroke rate as low as 1.1%, even though 73% of patients had a contraindication to and were not using oral anticoagulation.

1 January 2012 in Circulation
Verified
Journal Article
Closed access
PDF file
LBLucas V.A. Boersma
Lucas V.A. Boersma
MCManuel Castella
Manuel Castella
WBWimJan van Boven
WimJan van Boven
ABAntonio Berruezo
Antonio Berruezo
AYAlaaddin Yilmaz
Alaaddin Yilmaz
LMLluís Mont
Lluís Mont
Background—: Catheter ablation (CA) and minimally invasive surgical ablation (SA) have become accepted therapy for antiarrhythmic drug–refractory atrial fibrillation. This study describes the first randomized clinical trial comparing their efficacy and safety during a 12-month follow-up. Methods and Results—: One hundred twenty-four patients with antiarrhythmic drug–refractory atrial fibrillation with left atrial dilatation and hypertension (42 patients, 33%) or failed prior CA (82 patients, 67%) were randomized to CA (63 patients) or SA (61 patients). CA consisted of linear antral pulmonary vein isolation and optional additional lines. SA consisted of bipolar radiofrequency isolation of the bilateral pulmonary vein, ganglionated plexi ablation, and left atrial appendage excision with optional additional lines. Follow-up at 6 and 12 months was performed by ECG and 7-day Holter recording. The primary end point, freedom from left atrial arrhythmia >30 seconds without antiarrhythmic drugs after 12 months, was 36.5% for CA and 65.6% for SA ( P =0.0022). There was no difference in effect for subgroups, which was consistent at both sites. The primary safety end point of significant adverse events during the 12-month follow-up was significantly higher for SA than for CA (n=21 [34.4%] versus n=10 [15.9%]; P =0.027), driven mainly by procedural complications such as pneumothorax, major bleeding, and the need for pacemaker. In the CA group, 1 patient died at 1 month of subarachnoid hemorrhage. Conclusion—: In atrial fibrillation patients with dilated left atrium and hypertension or failed prior atrial fibrillation CA, SA is superior to CA in achieving freedom from left atrial arrhythmias after 12 months of follow-up, although the procedural adverse event rate is significantly higher for SA than for CA. Clinical Trial Registration—: URL: http://clinicaltrials.gov . Unique identifier: NCT00662701.

1 August 2017 in JACC
Verified
Journal Article
Open access
LBLucas Boersma
Lucas Boersma
CBCraig Barr
Craig Barr
RKReinoud Knops
Reinoud Knops
DTDominic Theuns
Dominic Theuns
LELars Eckardt
Lars Eckardt
PLPier D. Lambiase
Pier D. Lambiase
The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. This is the first report on the full patient cohort and study endpoints with follow-up ≥1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. Patients were followed for 3.1 ± 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 ± 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (Evaluation oF Factors ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD [The EFFORTLESS S-ICD Registry]; NCT01085435).

5 January 2021 in Circulation
Verified
Journal Article
Open access
PDF file
MGMichael R. Gold
Michael R. Gold
PLPier D. Lambiase
Pier D. Lambiase
MEMikhael F El-Chami
Mikhael F El-Chami
RKReinoud E. Knops
Reinoud E. Knops
JAJohan D. Aasbo
Johan D. Aasbo
LBLucas V. Boersma
Lucas V. Boersma
Background: The Subcutaneous ICD (S-ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, less left ventricular dysfunction and received more inappropriate shocks (IAS) than in typical transvenous (TV)-ICD trials. The UNTOUCHED trial was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. Methods: Primary prevention patients with left ventricular ejection fraction (LVEF) ≤ 35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥ 250 beats per minute (bpm) and morphology discrimination for rates ≥200 and < 250 bpm. Patients were followed for 18 months. The primary endpoint was the IAS free rate compared to a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study. Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of endpoints. Results: S-ICD implant was attempted in 1116 patients and 1111 patients were included in post-implant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% women, 23.4% black race, 53.5% with ischemic heart disease, 87.7% with symptomatic heart failure and a mean LVEF of 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (Lower confidence limit LCL 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the three-incision technique, no history of atrial fibrillation, and ischemic etiology. The 18-month all cause shock free rate was 90.6% (LCL 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication free rate at 18 months was 92.7%. Conclusions: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of co-morbidities in comparison to earlier S-ICD trials. The inappropriate shock rate (3.1% at one year) is the lowest reported for the S-ICD and lower than many TV ICD studies using contemporary programming to reduce IAS. Clinical Trial Registration: URL https://clinicaltrials.gov Unique Identifier NCT02433379