Mingyue Gong

Mingyue Gong

Auto-generated profile, based on publicly available information

Mingyue Gong

Department of Biomedical Engineering, Xiangya School of Basic Medical Sciences, Central South University, Changsha 410013, Hunan, P. R. China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2025 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
XMXiaoxiao Men
Xiaoxiao Men
FLFanghong Liu
Fanghong Liu
MGMingyue Gong
Mingyue Gong
XWXuchao Wang
Xuchao Wang
LWLing Wang
Ling Wang
ZDZhuxin Dong
Zhuxin Dong
Liver cancer, specifically hepatocellular carcinoma (HCC), is a malignant neoplasm of the digestive system, characterized by exceptionally high morbidity and mortality rates on a global scale. Early detection and diagnosis are critical measures for enhancing the prognosis of patients diagnosed with HCC. An improved prognosis is significantly reliant on the timely diagnosis of the disease and effective therapeutic monitoring. Activatable fluorescent probes are essential for detecting and imaging biomarkers related to disease diagnosis and in vivo imaging. This paper reviews the fluorescent probes developed over the past five years for the detection and imaging of HCC. This noninvasive optical imaging modality demonstrates significant promise in targeting pathological sites and is anticipated to facilitate potential clinical translation.

6 November 2024 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
YLYunhe Luo
Yunhe Luo
SZSiyu Zhou
Siyu Zhou
MGMingyue Gong
Mingyue Gong
CWChangfeng Wu
Changfeng Wu
XFXiaofeng Fang
Xiaofeng Fang
Self-labeling protein (SLP) tags, such as HaloTag, have gained considerable interest as advanced tools for live cell labeling. However, the chloroalkane-based substrates that can be directly used for protein labeling are limited. Here, we report two bioorthogonal small molecule linkers, chloroalkane-tetrazine (CA-Tz) and chloroalkane-azide (CA-N3), which can penetrate cell membranes and facilitate click chemistry-based labeling in live cells. We compare their labeling capability using two clickable silicon rhodamine dyes (SiR-PEG3-TCO and SiR-PEG4-DBCO). Confocal imaging results demonstrate that using CA-Tz and SiR-PEG3-TCO dye exhibits superior intracellular labeling with low nonspecific signals. We subsequently compared the photostability of SiR dyes with that of green fluorescent proteins (mEmerald). Total internal reflection fluorescence (TIRF) imaging indicates that SiR dyes exhibit superior photostability under identical excitation conditions, making them suitable for long-term cell imaging. Furthermore, SiR dyes labeling also shows high structure retention for the fourth-order super-resolution optical fluctuation imaging (SOFI) compared to fluorescent proteins. This study presents clickable HaloTag linkers as effective tools for live cell labeling and imaging, highlighting the high-quality labeling of chloroalkane linkers and clickable dyes for live cell imaging.

12 March 2026 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
MGMingyue Gong
Mingyue Gong
ZWZhuli Wu
Zhuli Wu
YHYufang He
Yufang He
JXJiaying Xiao
Jiaying Xiao
XMXiaoju Men
Xiaoju Men
Haobin ChenHaobin Chen
Haobin Chen
Point-of-care testing (POCT) represents a significant innovation in healthcare diagnostics, driving the evolution of clinical practice and health management toward greater convenience and personalization. However, conventional invasive POCT techniques are constrained by patient discomfort, infection risk, and discontinuous monitoring inherent to blood sampling, thereby limiting their utility for the long-term management of chronic diseases and personalized health monitoring. To overcome these limitations, noninvasive POCT technologies have emerged. These platforms enable painless and continuous monitoring by detecting biomarkers in easily accessible biofluids, such as saliva, sweat, and tears. This review systematically summarizes recent advancements in noninvasive POCT, with a focus on the operational principles, representative applications, and developmental trends of electrochemical and optical sensing modalities. We also examine progress in the integration of these sensors with microfluidics and flexible electronics for wearable POCT systems. Furthermore, we critically discuss persistent challenges for clinical translation and commercialization, including biomarker correlation with systemic health, sample complexity, device integration, and data reliability. Finally, we offer perspectives on future directions, such as multimodal sensing, integration with intelligent algorithms, and convergence with theranostic applications.

13 October 2026 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
ZWZhuli Wu
Zhuli Wu
MGMingyue Gong
Mingyue Gong
YLYao Lu
Yao Lu
XFXiaofeng Fang
Xiaofeng Fang
YKYan Kuang
Yan Kuang
CWChangfeng Wu
Changfeng Wu
Precise quantification of tissue oxygenation (pO[Formula: see text] is important for understanding tumor progression and evaluating metabolic therapies. However, conventional intensity-based optical oxygen sensors suffer from severe signal fluctuations for in vivo measurements due to tissue scattering and excitation conditions. Here, we present a robust quantitative oxygen sensing platform by using ultra-bright phosphorescent semiconducting polymer dots (Pdots) and a custom-built time-gated phosphorescence lifetime imaging (PLIM) system. Polyfluorene serves as a light-harvesting unit that sensitizes oxygen-responsive metalloporphyrin moieties through intraparticle energy transfer, yielding bright oxygen-sensitive Pdots with a large excitation–emission separation. The PLIM system consists of an intensified scientific complementary metal–oxide–semiconductor (sCMOS) camera with an internal trigger for pulsed LED excitation. We demonstrated the longitudinal imaging of local microenvironmental pO 2 in a murine breast tumor model over an 8-day period. While intensity imaging suffers from signal degradation due to tumor growth and probe dilution, the PLIM system reliably captures a dynamic change in tumor oxygenation, with pO 2 increasing from a hypoxic level (<10[Formula: see text]mmHg) on Day 1 to ∼43[Formula: see text]mmHg on Day 8. This trend likely reflects tumor vascular remodeling during early-stage growth. Our study provides a promising tool for tracking subcutaneous tissue metabolic dynamics and evaluating hypoxia-targeted cancer therapies.