Linyan Zhang

Linyan Zhang

Auto-generated profile, based on publicly available information

Linyan Zhang

National Engineering Research Center for Fiber Optic Sensing Technology and Network, Wuhan University of Technology, Wuhan 430070, People’s Republic of China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HWHui Wang
Hui Wang
CWChaoqun Wu
Chaoqun Wu
LLLei Liang
Lei Liang
SDShu Dai
Shu Dai
LZLinyan Zhang
Linyan Zhang
XTXiaoling Tong
Xiaoling Tong
Addressing the critical need for vibration measurement in extreme cryogenic environments, this work introduces a novel cryogenic accelerometer integrating dual fiber Bragg gratings (FBGs), a seismic mass, an elliptic hinge, and a fixed base. We systematically derived the theoretical foundations governing its dynamic response parameters: sensitivity, natural frequency, and temperature-responsive performance of overall structure. A comprehensive theoretical model was developed, enabling simulation-based optimization to define its dynamic and thermal response performance. The cryogenic FBG accelerometer underwent rigorous test and characterization at both room temperature (293 K) and cryogenic conditions (83 K), as well as across the extensive 83–293 K thermal range. Experimental results closely aligned with theoretical predictions; the sensitivity exhibited a positive correlation with decreasing temperature, while the natural frequency exhibited an inverse relationship. Within the 83–293 K operational envelope, the accelerometer-maintained functionality across the 30–250 Hz bandwidth. The sensitivity values were quantified at 64.87 pm/g (293 K) and 68.17 pm/g (83 K). Demonstrating robust resilience to cross-axis effects, the maximum transverse interference measured was only 9.82% (293 K) and 9.71% (83 K). Deviations between the experimental and theoretical sensitivities were minimal (1.59% at 293 K, 5.44% at 83 K), as were those for the natural frequency (5.30% and 8.60%). 4J36 Invar alloy serves as the core structural material, which features a stable face-centered cubic crystal structure, an extremely low coefficient of thermal expansion (CTE), low thermal conductivity, and outstanding ductility and toughness, demonstrating exceptional suitability for measurement elements. Furthermore, the proposed cryogenic accelerometer delivers commendable dynamic response characteristics. Its compact form factor (45 $\times$ 25 $\times$ 15 mm) and lightweight (50 g) are complemented by the distinct advantage of enabling remote, simultaneous multipoint acceleration monitoring within ultracryogenic settings.

6 February 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
LLLei Liang
Lei Liang
LZLinyan Zhang
Linyan Zhang
YWYining Wang
Yining Wang
HWHui Wang
Hui Wang
XTXiaoling Tong
Xiaoling Tong
YZYuning Zhang
Yuning Zhang
In remote or infrastructure-deficient areas, fiber grating demodulators typically rely on battery power, making low power consumption essential for prolonged field operation. To address this need, a low-power tunable laser-based fiber grating demodulator has been developed in this paper, employing a variable step-length laser scanning strategy based on OTSU threshold segmentation. By optimizing the scanning method, the field-programmable gate array (FPGA) clock frequency has been reduced to one-tenth of its original value while maintaining the demodulation frequency, achieving a 42.57% reduction in dynamic power consumption for the FPGA scanning control module. Experimental results demonstrate that the developed demodulator maintains a demodulation frequency of 2.5 kHz with a typical power consumption of only 2.43 W, significantly outperforming comparable market products. This demodulator’s exceptional low-power performance and stable demodulation capability provide a reliable technical solution for long-term field monitoring applications.