Optimal atrial septal defect (ASD) closure should combine off-pump techniques with the effectiveness and versatility of open-heart techniques. We report our experience with off-pump ASD closure using the Universal Cardiac Introducer (UCI) in a porcine model. The goal was to create an ASD over the fossa ovale (FO) and position a patch over the ASD under ultrasound (US) imaging and augmented virtual reality guidance. An US probe (tracked with a magnetic tracking system) was positioned into the esophagus (transesophageal echocardiographic probe) for real-time image-guidance. The right atrium (RA) of six pigs was exposed via a right lateral thoracotomy or medial sternotomy. The UCI was attached to the RA wall. A punching tool was introduced via the UCI, navigated and positioned, under US guidance, to create an ASD into the FO. A patch with its holder and a stapling device were introduced into the RA via the UCI. The patch was positioned on the ASD. Occlusion of the ASD was determined using US and Doppler imaging. The FO membrane was excised successfully in all animals. US image-guidance provided excellent visualization. The patch was positioned in all cases with complete occlusion of the ASD. The stapling device proved too bulky, impeding circumferential positioning. Using the UCI, ASD closure was safe and feasible. US imaging, combined with virtual and augmented reality provided accurate navigating and positioning. This study also provided valuable information on the future design of anchoring devices for intracardiac procedures.
1 November 2010 in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
Objective: We report our experience with ultrasound augmented reality (US-AR) guidance for mitral valve prosthesis (MVP) implantation in the pig using off-pump, closed, beating intracardiac access through the Guiraudon Universal Cardiac Introducer attached to the left atrial appendage. Methods: Before testing US-AR guidance, a feasibility pilot study on nine pigs was performed using US alone. US-AR guidance, tested on a heart phantom, was subsequently used in three pigs (~65 kg) using a tracked transesophageal echocardiography probe, augmented with registration of a 3D computed tomography scan, and virtual representation of the MVP and clip-delivering tool (Clipper); three pigs were used to test feature-based registration. Results: Navigation of the MVP was facilitated by the 3D anatomic display. AR displayed the MVP and the Clipper within the Atamai Viewer, with excellent accuracy for tool placement. Positioning the Clipper was hampered by the design of the MVP holder and Clipper. These limitations were well displayed by AR, which provided guidance for improved design of tools. Conclusions: US-AR provided informative image guidance. It documented the flaws of the current implantation technology. This information could not be obtained by any other method of evaluation. These evaluations provided guidance for designing an integrated tool: combining an unobtrusive valve holder that allows the MVP to function properly as soon as positioned, and an anchoring system, with clips that can be released one at a time, and retracted if necessary, for optimal results. The portability of Real-time US-AR may prove to be the ideal practical image guidance system for all closed intracardiac interventions.