21 November 2018 in 3D Printing in Medicine
Medical three-dimensional (3D) printing has expanded dramatically over the past three decades with growth in both facility adoption and the variety of medical applications. Consideration for each step required to create accurate 3D printed models from medical imaging data impacts patient care and management. In this paper, a writing group representing the Radiological Society of North America Special Interest Group on 3D Printing (SIG) provides recommendations that have been vetted and voted on by the SIG active membership. This body of work includes appropriate clinical use of anatomic models 3D printed for diagnostic use in the care of patients with specific medical conditions. The recommendations provide guidance for approaches and tools in medical 3D printing, from image acquisition, segmentation of the desired anatomy intended for 3D printing, creation of a 3D-printable model, and post-processing of 3D printed anatomic models for patient care.
17 March 2017 in 3D Printing in Medicine
Medical 3D printing is expanding exponentially, with tremendous potential yet to be realized in nearly all facets of medicine. Unfortunately, multiple informal subdomain-specific isolated terminological ‘silos’ where disparate terminology is used for similar concepts are also arising as rapidly. It is imperative to formalize the foundational terminology at this early stage to facilitate future knowledge integration, collaborative research, and appropriate reimbursement. The purpose of this work is to develop objective, literature-based consensus-building methodology for the medical 3D printing domain to support expert consensus. We first quantitatively survey the temporal, conceptual, and geographic diversity of all existing published applications within medical 3D printing literature and establish the existence of self-isolating research clusters. We then demonstrate an automated objective methodology to aid in establishing a terminological consensus for the field based on objective analysis of the existing literature. The resultant analysis provides a rich overview of the 3D printing literature, including publication statistics and trends globally, chronologically, technologically, and within each major medical discipline. The proposed methodology is used to objectively establish the dominance of the term “3D printing” to represent a collection of technologies that produce physical models in the medical setting. We demonstrate that specific domains do not use this term in line with objective consensus and call for its universal adoption. Our methodology can be applied to the entirety of medical 3D printing literature to obtain a complete, validated, and objective set of recommended and synonymous definitions to aid expert bodies in building ontological consensus.
1 February 2018 in The Lancet
1 March 2017 in 3D Printing in Medicine
In this work, we provide specific clinical examples to demonstrate basic practical techniques involved in image segmentation, computer-aided design, and 3D printing. A step-by-step approach using United States Food and Drug Administration cleared software is provided to enhance surgical intervention in a patient with a complex superior sulcus tumor. Furthermore, patient-specific device creation is demonstrated using dedicated computer-aided design software. Relevant anatomy for these tasks is obtained from CT Digital Imaging and Communications in Medicine images, leading to the generation of 3D printable files and delivery of these files to a 3D printer.
12 April 2018 in British Journal of Radiology
Objective:Results of the use of the transluminal attenuation gradient (TAG) at coronary CT angiography (CCTA) to predict hemodynamically significant disease vary widely. This study tested whether diagnostic performance of TAG to predict fractional flow reserve (FFR) ≤ 0.8 is improved when applied separately to subsets of coronary arteries that carry similar physiological flow.Methods:28 patients with 64 × 0.5 mm CCTA and invasive FFR in ≥1 major coronary artery were retrospectively evaluated. Two readers assessed TAG in each artery. The receiver operating characteristic (ROC) area under the curve (AUC) was used to assess the diagnostic performance of TAG to detect hemodynamically significant disease following a clinical use rule [negative: FFR > 0.8 or ≤ 25% diameter stenosis (DS) at invasive catheter angiography; positive: FFR ≤ 0.8 or ≥ 90% DS at invasive catheter angiography]. ROC AUC was compared for all arteries pooled together, vs separately for arteries carrying similar physiological flow (Group 1:...