Tea Covic

Tea Covic

Auto-generated profile, based on publicly available information

Tea Covic

Department of Vascular Surgery, Ospedale Civile di Baggiovara, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio Emilia, Modena, Italy

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2021 in Vascular
Verified
Journal Article
Open access
PDF file
SGStefano Gennai
Stefano Gennai
NLNicola Leone
Nicola Leone
LBLuigi A Maria Bartolotti
Luigi A Maria Bartolotti
TCTea Covic
Tea Covic
ALAntonio Lauricella
Antonio Lauricella
RSRoberto Silingardi
Roberto Silingardi
To compare endoleak outcomes after thoracic endovascular aneurysm repair (TEVAR) with different stent-graft generations into long-term follow-up. retrospective, observational, and single-center cohort study. TEVAR procedures performed between November 1995 and December 2020 were analyzed. The primary endpoint of this study was the freedom from endoleak (type I/III) in four stent-graft generations during the follow-up period. The first generation (GEN1) included: Vanguard; AneuRx and Talent; Stentor; Excluder; Endologix; EndoFit. The second generation (GEN2) included: TAG and TX. The third (GEN3) included: Relay Plus; Valiant Captivia; Zenith Alpha and custom-made. The fourth (GEN4) included: Relay Pro; Conformable C-TAG; Navion; E-Vita; Najuta; Nexus; standard and custom-made thoraco-abdominal devices. Nonaortic and aorta-related survival was considered as secondary outcome. A total of 509 TEVAR were included with a 44.3 ± 42.5 months mean follow-up. Freedom from endoleak at 5 years was 65.6%, 61.4%, 76.2%, and 69.1% for GEN1, GEN2, GEN3, and GEN4, respectively (p = 0.368). The first two generations demonstrated a higher endoleak rate when compared with the two most recent ones (27.2 vs 18.2%, respectively; p = 0.043). GEN1 was an independent risk factor (p = 0.014) and GEN4 was an independent protective factor (p = 0.001) for endoleak. GEN1 was found to be a risk factor for type-Ia endoleak (p = 0.059). GEN4 demonstrated a protective association regarding type-Ib endoleak (p = 0.012). Overall survival was 75.3%, 44.4%, 27.2%, and 17.6% at 1, 5, 10, and 15 years, respectively. Survival distinguished as non-related versus aortic-related was 86.7% vs 23.5%, 52.7% vs 9.8%, 32.9% vs 2.0%, 21.2% vs 0% at 1, 5, 10, and 15 years, respectively (p< 0.000). Endoleak occurred in a non-negligible percentage of TEVAR patients. A significant reduction of endoleak incidence over evolving stent-grafts generations was registered. Newer stent-graft generations demonstrated better long-term endoleak. Data about long-term outcomes require ongoing updates to prove both the reliability and the durability of newer stent-graft generations.

19 July 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
SGStefano Gennai
Stefano Gennai
FAFrancesco Andreoli
Francesco Andreoli
GSGiuseppe Saitta
Giuseppe Saitta
NLNicola Leone
Nicola Leone
MMMattia Migliari
Mattia Migliari
RSRoberto Silingardi
Roberto Silingardi
Objective: The introduction of new endograft models improved long-term results of abdominal aortic aneurysm (AAA) endovascular repair (EVAR), but most of them maintained an old and unchanged design: a short body and long legs shifting up the flow divider. This study assessed the long-term results of EVAR with unimodular endoprosthesis fixed at the aorto-iliac bifurcation (Anatomical FiXation), in a large, unselected cohort. Materials and Methods: In a single-center, retrospective cohort study, 623 patients selectively treated between 1999 and 2016, were analyzed. Follow-up protocol included at least a computed tomography angiography within 3 months and a duplex ultrasound and clinical exam yearly. All enrolled patients were analyzed by 2020. The primary outcomes were technical success, clinical success, and survival. Secondary outcomes included survival-free from late-open-conversion (LOC), reintervention, and endoleaks. Results: Median age was 74±11 years and the follow-up 93±54 months. The technical success was achieved in 99.4% and the 30-day clinical success was 98.4%. A 5-year clinical success of 97.7% was registered and at 10 years success was 96.7%. The overall survival at 1, 5, 10, and 15 years was 92.4%, 79.5%, 64.9%, and 45.5%, respectively. Six (0.98%) AAA-related death were registered, 3 caused by infection of the endograft and 3 for secondary rupture. LOCs were 9 (1.47%) and reintervention-free survival at 1, 5, 10, and 15 years were 88.4%, 78.0%, 76.2%, and 74.6%, respectively. Freedom from endoleaks was 88.8% at 1 year and 72.7% at 15 years. A total of 63 high-flow endoleaks were registered (43 type I, 7 type IIIa, 12 type IIIb, and 1 type Ib+IIIb). No migrations were recorded, and the graft limb thrombosis rate was 1.14%. From a multivariate analysis resulted that long-term clinical success appeared to be reduced in patients affected by diabetes [odds ratio (OR) 0.24; p=0.04] and in presence of calcified and thrombotic iliac accesses (OR 0.16; p=0.006). Conclusion: EVAR with the Anatomical FiXation was confirmed to be safe, feasible, and effective to prevent AAA rupture in the long term as well. However, the overall survival remains afflicted by cardiovascular accident. The original concept of unibody bifurcated design allowed a very low rate of graft thrombosis and zeroed the risk of migration and related reintervention.

1 February 2021 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
ALAntonio Lauricella
Antonio Lauricella
SGStefano Gennai
Stefano Gennai
TCTea Covic
Tea Covic
NLNicola Leone
Nicola Leone
MMMattia Migliari
Mattia Migliari
RSRoberto Silingardi
Roberto Silingardi

5 September 2022 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
SGStefano Gennai
Stefano Gennai
TCTea Covic
Tea Covic
NLNicola Leone
Nicola Leone
AXAndrea Xodo
Andrea Xodo
MAMichele Antonello
Michele Antonello
RSRoberto Silingardi
Roberto Silingardi

31 October 2024 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
LNLeone Nicola
Leone Nicola
BFBaresi Giovanni Francesco
Baresi Giovanni Francesco
CTCovic Tea
Covic Tea
PGPizzarelli Ginevra
Pizzarelli Ginevra
LALauricella Antonio
Lauricella Antonio
GSGennai Stefano
Gennai Stefano

14 July 2021 in Diagnostic and Interventional Radiology
Verified
Journal Article
Closed access
TCTea Covic
Tea Covic
NLNicola Leone
Nicola Leone
SGStefano Gennai
Stefano Gennai
RSRoberto Silingardi
Roberto Silingardi
A 58-year- old man with a history of aortic and mitral mechanical valve replacement was referred to our hospital for symptomatic chronic heart failure. In 1988, he had undergone open surgical correction of an isthmic aortic coarctation (CoA), with the creation of an extra-anatomic bypass from the left subclavian artery to the descending thoracic aorta. The following findings were found: severe mitral valve failure with perivalvular leakage, severe aortic valve stenosis, pulmonary hypertension, distal anastomotic aneurysm with the apparent occlusion of the CoA. A thoracic endovascular aneurysm repair was performed. A postoperative high-pressure leak with no evident signs of ineffective sealing was observed. Computed tomography angiography (CTA) 3D reconstruction demonstrated the recanalization of the CoA. A second procedure was planned. The CoA was anterogradely cannulated. Three coils were deployed into the aneurysmal sac, followed by a vascular plug, positioned on the coarctation conduit, but it failed to anchor and dislocated into the sac. A second plug was deployed, but it also partially dislocated. Finally, a patent foramen ovale occluder device was deployed to occlude the communication. The final angiogram showed the complete occlusion of the coarctation and correction of the leak, which was confirmed by a 6-month post-operative CTA.