8 December 2021 in Optica
We present snapshot hyperspectral light field tomography (Hyper-LIFT), a highly efficient method in recording a 5D (,, spatial coordinates;,, angular coordinates;, wavelength) plenoptic function. Using a Dove prism array and a cylindrical lens array, we simultaneously acquire multi-angled 1Den faceprojections of the object like those in standard sparse-view computed tomography. We further disperse those projections and measure the spectra in parallel using a 2D image sensor. Within a single snapshot, the resultant system can capture a 5D data cube withvoxels. We demonstrated the performance of Hyper-LIFT in imaging spectral volumetric scenes.
31 January 2020 in Optics Letters
In this Letter, we present a snapshot hyperspectral light field imaging system using a single camera. By integrating an unfocused light field camera with a snapshot hyperspectral imager, the image mapping spectrometer, we captured a five-dimensional (5D) ( ) ( spatial coordinates; emittance angles; wavelength) datacube in a single camera exposure. The corresponding volumetric image ( ) at each wavelength is then computed through a scale-depth space transform. We demonstrated the snapshot advantage of our system by imaging the spectral-volumetric scenes in real time.
8 March 2019 in Applied Optics
A chromatic confocal microscopy system in combination with two liquid crystal display (LCD) panels is proposed and demonstrated for surface profiling. The major advantage of this system is no mechanical translation is needed for three-dimensional (3D) imaging. Axial scanning is realized thanks to the chromatic aberration in the objective, whereas lateral scanning is achieved by turning on different pixels on LCDs. Chromatic aberration of the objective lens is used to provide wavelength-to-depth coding, and decoding is realized by using a dispersion prism. System performance is validated with a 50 μm step standard and the capability of 3D imaging is demonstrated with an onion epidermis.
28 September 2020 in Biomedical Optics Express
Prevalent techniques in label-free linear optical microscopy are either confined to imaging in two dimensions or rely on scanning, both of which restrict their applications in imaging subtle biological dynamics. In this paper, we present the theoretical basis along with demonstrations supporting that full-field spectral-domain interferometry can be used for imaging samples in 3D with no moving parts in a single shot. Consequently, we propose a novel optical imaging modality that combines low-coherence interferometry with hyperspectral imaging using a light-emitting diode and an image mapping spectrometer, called Snapshot optical coherence microscopy (OCM). Having first proved the feasibility of Snapshot OCM through theoretical modeling and a comprehensive simulation, we demonstrate an implementation of the technique using off-the-shelf components capable of capturing an entire volume in 5 ms. The performance of Snapshot OCM, when imaging optical targets, shows its capability to axially localize and section images over an axial range of ±10 µm, while maintaining a transverse resolution of 0.8 µm, an axial resolution of 1.4 µm, and a sensitivity of up to 80 dB. Additionally, its performance in imaging weakly scattering live cells shows its capability to not only localize the cells in a densely populated culture but also to generate detailed phase profiles of the structures at each depth for long durations. Consolidating the advantages of several widespread optical microscopy modalities, Snapshot OCM has the potential to be a versatile imaging technique for a broad range of applications.
7 July 2020 in Applied Optics
An image mapping spectrometer (IMS) is a snapshot hyperspectral imager that simultaneously captures both the spatial ( , ) and spectral ( ) information of incoming light. The IMS maps a three-dimensional (3D) datacube ( , , ) to a two-dimensional (2D) detector array ( , ) for parallel measurement. To reconstruct the original 3D datacube, one must construct a lookup table that connects voxels in the datacube and pixels in the raw image. Previous calibration methods suffer from either low speed or poor image quality. We herein present a slit-scan calibration method that can significantly reduce the calibration time while maintaining high accuracy. Moreover, we quantitatively analyzed the major artifact in the IMS, the striped image, and developed three numerical methods to correct for it.
20 October 2023 in Optics Express
Multidimensional imaging has emerged as a powerful technology capable of simultaneously acquiring spatial, spectral, and depth information about a scene. However, existing approaches often rely on mechanical scanning or multi-modal sensing configurations, leading to prolonged acquisition times and increased system complexity. Coded aperture snapshot spectral imaging (CASSI) has introduced compressed sensing to recover three-dimensional (3D) spatial-spectral datacubes from single snapshot two-dimensional (2D) measurements. Despite its advantages, the reconstruction problem remains severely underdetermined due to the high compression ratio, resulting in limited spatial and spectral reconstruction quality. To overcome this challenge, we developed a novel two-stage cascaded compressed sensing scheme called coded aperture snapshot hyperspectral light field tomography (CASH-LIFT). By appropriately distributing the computation load to each stage, this method utilizes the compressibility of natural scenes in multiple domains, reducing the ill-posed nature of datacube recovery and achieving enhanced spatial resolution, suppressed aliasing artifacts, and improved spectral fidelity. Additionally, leveraging the snapshot 3D imaging capability of LIFT, our approach efficiently records a five-dimensional (5D) plenoptic function in a single snapshot.