Jim-Felix Lobsien

Jim-Felix Lobsien

Auto-generated profile, based on publicly available information

Jim-Felix Lobsien

Max-Planck Institut für Plasmaphysik, Wendelsteinstraße 1, Greifswald 17491, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2025 in Fusion Engineering and Design
Verified
Journal Article
Open access
JLJ. Lion
J. Lion
JAJ.-C. Anglès
J.-C. Anglès
LBL. Bonauer
L. Bonauer
ANA. Bañón Navarro
A. Bañón Navarro
SCS.A. Cadena Ceron
S.A. Cadena Ceron
MZM. Zheng
M. Zheng

28 September 2022 in Journal of Plasma Physics
Verified
Journal Article
Open access
PDF file
RJR. Jorge
R. Jorge
GPG.G. Plunk
G.G. Plunk
MDM. Drevlak
M. Drevlak
MLM. Landreman
M. Landreman
JLJ.-F. Lobsien
J.-F. Lobsien
PHP. Helander
P. Helander
A single-field-period quasi-isodynamic stellarator configuration is presented. This configuration, which resembles a twisted strip, is obtained by the method of direct construction, that is, it is found via an expansion in the distance from the magnetic axis. Its discovery, however, relied on an additional step involving numerical optimization, performed within the space of near-axis configurations defined by a set of adjustable magnetic field parameters. This optimization, completed in 30 s on a single CPU core using the SIMSOPT code, yields a solution with excellent confinement, as measured by the conventional figure of merit for neoclassical transport, effective ripple, at a modest aspect ratio of eight. The optimization parameters that led to this configuration are described, its confinement properties are assessed and a set of magnetic field coils is found. The resulting transport at low collisionality is much smaller than that of W7-X, and the device needs significantly fewer coils because of the reduced number of field periods.

1 August 2018 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
JLJim-Felix Lobsien
Jim-Felix Lobsien
MDMichael Drevlak
Michael Drevlak
TPThomas Sunn Pedersen
Thomas Sunn Pedersen

4 July 2024 in Superconductor Science and Technology
Verified
Journal Article
Open access
PHP Huslage
P Huslage
DKD Kulla
D Kulla
JLJ-F Lobsien
J-F Lobsien
TST Schuler
T Schuler
ESE V Stenson
E V Stenson
We designed and constructed two non-planar coils with high-temperature superconductors (HTS) based on shapes from the Wendelstein 7-X stellarator. Tape track orientation of the HTS was optimized to reduce the coil size as much as possible while staying within the strain limits of the gadolinium barium copper oxide (GdBCO) superconductor. This resulted in average coil radii of 0.23 m and 0.48 m at strain limits of up 0.45% to for the coil shapes that were chosen. The coils were produced by winding the GdBCO tapes onto 3D-printed plastic frames. We confirmed the integrity of the superconducting layer after winding by spatially resolved measurement of the critical current and by energizing the coils in liquid nitrogen. Coil 1 showed a resistance of 1.75 μ Ω and did not have any critical current degradation, while coil 5 had a resistance of 195 μ Ω and showed only one dropout, attributable to a handling error. We measured the magnetic field of the coil with a three-axis Hall probe system and found good agreement with predictions. This work demonstrates the manufacturing of small-scale, non-planar magnetic coils from commercially available HTS.

1 April 2020 in Journal of Plasma Physics
Verified
Journal Article
Open access
PDF file
JLJim-Felix Lobsien
Jim-Felix Lobsien
MDMichael Drevlak
Michael Drevlak
TKThomas Kruger
Thomas Kruger
SLSamuel Lazerson
Samuel Lazerson
CZCaoxiang Zhu
Caoxiang Zhu
TPThomas Sunn Pedersen
Thomas Sunn Pedersen
Following up on earlier work which demonstrated an improved numerical stellarator coil design optimization performance by the use of stochastic optimization (Lobsien et al., Nucl. Fusion, vol. 58 (10), 2018, 106013), it is demonstrated here that significant further improvements can be made - lower field errors and improved robustness - for a Wendelstein 7-X test case. This is done by increasing the sample size and applying fully three-dimensional perturbations, but most importantly, by changing the design sequence in which the optimization targets are applied: optimization for field error is conducted first, with coil shape penalties only added to the objective function at a later step in the design process. A robust, feasible coil configuration with a local maximum field error of 3.66 % and an average field error of 0.95 % is achieved here, as compared to a maximum local field error of 6.08 % and average field error of 1.56 % found in our earlier work. These new results are compared to those found without stochastic optimization using the FOCUS and ONSET suites. The relationship between local minima in the optimization space and coil shape penalties is also discussed.

31 January 2020 in Nuclear Fusion
Verified
Journal Article
Closed access
PDF file
JLJim-Felix Lobsien
Jim-Felix Lobsien
MDMichael Drevlak
Michael Drevlak
FJFrank Jenko
Frank Jenko
MMMaurice Maurer
Maurice Maurer
ANAlejandro Banon Navarro
Alejandro Banon Navarro
YTYuriy Turkin
Yuriy Turkin
In this paper we follow up on the results from our previous publication [Lobsien J, et al., Nucl. Fus., Vol 58 (2018)106013], where it was found that stellarator coil design optimization can be substantially improved by using a stochastic optimisation approach. In that paper performance was quantified by lower (better) and more narrow (more robust) distributions of the penalty functions at the end of the optimisations. Here, we evaluate and compare the various coil sets of the previous paper but seek a verification and deeper understanding of the physics performance by replacing the relatively simple penalty function estimate with more accurate ones from state-of-the-art calculations of MHD stability, neoclassical transport in the $1/\nu$-regime, fast particle confinement, and gyrokinetic behavior. The investigation shows that stochastic stellarator coil optimization generally outperforms the earlier non-stochastic stellarator optimization, also when using these more accurate metrics, generally confirming and quantifying the better performance. We do find some discrepancies, indicating that the penalty function does not represent a physics performance optimum perfectly. For example, as pointed out by others before us, the depth of the magnetic well is not a sufficiently good proxy for MHD stability, and the neoclassical transport can be significantly reduced in configurations that have relatively high field errors and therefore high penalty values. Thus, our work points to areas where better physics model inside the optimisation loop are needed, than what is currently represented by our penalty function.