Lisia Lorea Valente

Lisia Lorea Valente

Auto-generated profile, based on publicly available information

Lisia Lorea Valente

Universidade Federal de Pelotas, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
JSJosé Augusto Sedrez-Porto
José Augusto Sedrez-Porto
EMEliseu Aldrighi Münchow
Eliseu Aldrighi Münchow
LVLisia Lorea Valente
Lisia Lorea Valente
MCMaximiliano Sergio Cenci
Maximiliano Sergio Cenci
TPTatiana Pereira-Cenci
Tatiana Pereira-Cenci
The aim of this study was to investigate the mechanical performance and the fracture behavior of endocrown restorations prepared using distinct restorative materials. A total of 42 sound molars with similar crown size and shape were cut at 2 mm above the cementoenamel junction and endodontically treated. They were categorized according to the restorative material used to fabricate endocrown restorations (n=7), namely, conventional composite (Filtek™ Z350 XT), bulk fill composite (Filtek™ Bulk Fill), conventional composite modeled using resin adhesives (SBMP: Scotchbond™ Multipurpose Adhesive; or SBU: Scotchbond™ Universal Adhesive), and IPS e.max lithium disilicate (Ivoclar Vivadent; positive control). Unprepared sound teeth were used as negative control. All endocrowns were bonded using a self-adhesive cement (Rely-X™ U200). The teeth were submitted to fatigue (Byocycle) and fracture (EMIC DL500) testing. Load-to-fracture (in N) and work-of-fracture (Wf, in J/m2) values were analyzed by ANOVA (p < 0.05). The endocrowns did not fracture or de-bond upon fatigue, showing similar load-to-fracture and work-of-fracture values, regardless of the restorative material (p > 0.05). The endocrowns fabricated by combining Z350 and SBMP had the least harsh fractures, in contrast to endocrowns prepared using Z350 only, which exhibited an equilibrium between repairable and irrepairable fractures. The e.max endocrowns exhibited more aggressive failures (root fracture) than other groups, resulting in higher rates of irrepairable fractures. In conclusion, dental practitioners may satisfactorily restore severely damaged nonvital teeth using the endocrown technique. Composite endocrowns prepared using resin adhesive as modeler liquid or using bulk fill material may result in less aggressive failures, thus providing a new material perspective for endocrown restorations.

1 January 2024 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
Afnan O. Al-ZainAfnan O. Al-Zain
Afnan O. Al-Zain
EVANDRO PIVAEVANDRO PIVA
EVANDRO PIVA
APAlice Hammes Pimentel
Alice Hammes Pimentel
CDCamila Gonçalves Duarte
Camila Gonçalves Duarte
LVLisia Lorea Valente
Lisia Lorea Valente
EMEliseu Aldrighi Münchow
Eliseu Aldrighi Münchow
This study investigated the impact of ‘storage condition’ and ‘period of storage’ on selected physico-mechanical properties and fracture reliability of a resin-based composite (RBC). Specimens, prepared from a nanofilled RBC (Filtek Z350 XT; 3M ESPE), underwent tests for degree of conversion (DC), flexural strength (σ), flexural modulus (E), and hardness. The specimens were initially grouped into dry storage at 37°C or wet storage in distilled water at 37°C. Subsequently, they were further divided into four subgroups based on the period of storage: 6, 24, 72, or 168 hours. Specimens tested immediately after preparation served as control. Data analysis employed two-way ANOVA and Weibull analysis (α = 5%). Compared to the control, an increase in DC was observed only after 72 hours of dry storage; σ showed higher values after both dry and wet storage, regardless of the storage period (except for the group wet-stored for 168 hours); E increased with dry storage for at least 24 hours or wet storage for 72 hours; and hardness increased after dry storage for at least 24 hours or wet storage for up to 72 hours. The Weibull modulus remained unchanged under any of the distinct storage conditions. Dry storage resulted in greater characteristic strength than the control, whereas wet storage contributed to higher strength values only at shorter periods (up to 24 hours). Overall, the inherent properties of RBCs with a similar composition to that tested in this study may change with varying storage conditions and periods.