Sébastien A. Brideau

Sébastien A. Brideau

Auto-generated profile, based on publicly available information

Sébastien A. Brideau

CanmetENERGY, Natural Resources Canada, Ottawa, Canada

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Solar Energy
Verified
Journal Article
Closed access
SBSébastien A. Brideau
Sébastien A. Brideau
MCMichael R. Collins
Michael R. Collins

1 January 2012 in Energy Procedia
Verified
Journal Article
Open access
SBSébastien A. Brideau
Sébastien A. Brideau
MCMichael R. Collins
Michael R. Collins
In order to increase the efficiency of an air-based hybrid Photovoltaic/Thermal solar collector, a high heat transfer coefficient can be achieved between the absorber plate and the air by using impinging jets. A predictive model of a PV/Thermal collector using impinging jets was developed, and a prototype was built and operated at an outdoor facility in order to validate and test the model capabilities. Overall, the model was found to produce relatively accurate results. Over 8 days of testing, the worst total daily energy model predictions were within 10% and 11% of the experimental value for the thermal and electrical outputs, respectively. The influence of time step and thermal mass on the accuracy of the model were examined

30 March 2025 in Energy and Buildings
Verified
Journal Article
Open access
CSChun Yin Siu
Chun Yin Siu
SBSarah Brown
Sarah Brown
SBSébastien Brideau
Sébastien Brideau
LJLili Ji
Lili Ji
WOWilliam O’bRien
William O’bRien
NDNina Dmytrenko
Nina Dmytrenko

5 February 2020 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
SBSébastien A. Brideau
Sébastien A. Brideau
IBIan Beausoleil-Morrison
Ian Beausoleil-Morrison
MKMichaël Kummert
Michaël Kummert
This paper discusses various reactive and predictive controllers, with and without setback, and floor construction, for radiant floor heating in a single detached house in a cold climate, with high variability in solar gains. Heating energy to the floor and occupant comfort were evaluated. Modeling showed that in general, lower thermal mass floors performed better in cases with lower solar gains variability (lower south-facing glazing area). For high solar gains variability, floors with higher mass tended to provide better comfort, as long as the tubes were located near the surface of the floor. Temperature setback generally was found to provide modest heating energy savings, and decreased overheating periods. Proportional Integral Derivative (PID) and Outdoor Temperature Reset with Indoor Temperature Feedback controllers were found to generally perform the best for all cases. It was found that proper selection of controller and floor construction can make a difference in heating energy demand by as much as 25%.

20 November 2017 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
SBS.A. Brideau
S.A. Brideau
IBI. Beausoleil-Morrison
I. Beausoleil-Morrison
MKM. Kummert
M. Kummert
While some building energy simulation tools include dedicated models to represent thermally massive embedded-tubes radiant floor systems, there are no models available for lightweight above-floor tube-and-plate (AFTP) systems. AFTP systems consist of a grooved wooden subfloor (or high density insulation layer), and conductive fin. This paper discusses the development of a transient AFTP radiant floor model and its implementation into ESP-r. This AFTP radiant floor model uses the general approach of the existing embedded-tube model in ESP-r and combines an analytical model of the tube with a two-dimensional finite difference model of the top layers of the floor construction. The new AFTP radiant floor model was found to compare closely with a transient two-dimensional finite element analysis model. Additionally, a full-scale transient experiment was conducted to empirically validate the model. The new model's predictions were found to be in close agreement with the measurements from this experiment.