1 April 2024 in Indonesian Journal of Electrical Engineering and Computer Science
This research introduces a safety hysteresis comparator that detects transient overvoltage in the track circuit relay interlocking of railway signaling system. This overvoltage is caused by voltage faults transmitted through the electric conductor on the track feed unit to the receiver equipped with the track relay, which acts as the occupied track circuit controller. The circuit was designed using safety system design principles and concepts. Findings illustrated that the transient overvoltage detection of the safety hysteresis comparator in the track circuit activated when the input voltage (Vin) was higher than the high hysteresis signal level (Vhyst_H). When Vin was less than low hysteresis signal level (VVhyst_L), the output voltage (Vo) state was low. Otherwise, it was high. The hysteresis voltage was 4.4 V. The installation of the transient overvoltage detector in the track circuit was to monitor the transient overvoltage fault in the track circuit and to confirm that the hysteresis comparator was in the safety failure mode, which was the safety function for the track circuit to be compliant with the IEC 61800-5-2 standard to ensure the system stability and reliability. It would maximize the performance of the controlling function and commanding of train arrangement of State Railway of Thailand (SRT).
31 January 2024 in EUREKA: Physics and Engineering
This research presented the utilization of Safety Transient Voltage Suppressors (STVS) in the track circuits of railway signaling systems, occurring during circuit switching due to changes in track occupancy conditions, resulting in damage and malfunction of the BR966F2 relay. The study employed Failure Modes and Effect Analysis (FMEA) combined with 1kV actual transient overvoltage testing featuring a waveform slope of 184/380 μs. Results revealed two transient voltage suppression levels encompassing Set A_(a,b), Set B_(a) and Set C_(a,b) as well as Set A//Set B//Set C and All Mode. These configurations achieved a clamping voltage of 41.6 V, categorized as Stage 1. Configurations like Set A_(c), Set B_(b,c) and Set C_(c) displayed increased series circuit behavior leading to a clamping voltage of 48.6 V, categorized as Stage 2. The application of STVS device in the track circuit of the signaling system reduced the transient voltage by diversion of the Transient Current or ISTVS through the STVS device into the ground system or the clamping voltage at the STVS device. This prevented the transient power from flowing into and damaging the relays of the track circuit, leaving only the clamping voltage with a missing peak wave. This contributed to the stability of the track circuit within the railway signaling system while also raising the Safety Integrity Level (SIL) to a higher standard, in accordance with the specifications of IEC 16508-4 and the unique requirements of the State Railway of Thailand. These enhancements increased the advanced safety system within the track circuit, particularly for train control and train operation functions of the State Railway of Thailand
1 August 2025 in Indonesian Journal of Electrical Engineering and Computer Science
The research presented the design of safety electronic load suppression (SELS) for mitigating transient overvoltage in the track circuits of railway signaling systems while changing the track occupancy in the track circuits of the signaling system that caused damage to the BR966F2 relay. The analysis of the average failure of the electronic devices, the failure modes and effect analysis (FMEA), and the performance test of electronic devices were conducted. and the performance test of electronic devices were conducted. which can control the operation with 2oo3 processing mode (two out of three voting) under the series circuits pattern to resolve the damage caused by the application. Results illustrated that the mean operating time of the SELS between failures was 9,399 hours. In addition, regarding the performance of the electronic load for mitigating transient overvoltage of 1 kV at 31.4 V and overvoltage 50 VDC at 178.6 °C within 83 seconds at 35.4 V. Additionally, the SELS could function adequately without failure or causing any damage. Therefore, the SELS was more reliable.