Despite growing concern over occupational exposure to particulate matter (PM) such as grain dust and diesel exhaust, information about the exposure level and health implications among workers in small-scale milling enterprises in developing countries like Nigeria has not been adequately documented. The purpose of this study was to assess the level of exposure to grain dust and diesel exhaust and effect on lung function among grain millers in food markets in Ibadan metropolis, Nigeria. The study adopted descriptive cross-sectional design with a comparative approach. Sixteen grain milling shops each were randomly selected from two major food markets in Ibadan metropolis for indoor PM10 and PM2.5 monitoring. Seventy-two respondents each were proportionately selected from grain millers and shop owners for forced expiratory volume in one second and peak expiratory flow rate tests. The PM2.5 concentrations for both market locations ranged between 1,269.3 and 651.7 μg/m3, while PM10 concentrations were between 1,048.2 and 818.1 μg/m3. The recorded concentrations exceeded the World Health Organization guideline limit of 50 μg/m3 and 25 μg/m3 for PM2.5 and PM10, respectively. As compared with control group (2.1 L), significantly lower forced expiratory volume in one second value (1.61 L) was observed among the exposed group (p < 0.05). Likewise, significantly lower peak expiratory flow rate value (186.7 L/min) was recorded among the exposed group than the control group (269.51 L/min) (p < 0.05). Exposure to grain dust and diesel exhaust accentuated respiratory disorders with declines in lung functions amongst grain millers. Improved milling practices and engaging cleaner milling facilities should be adopted to minimize exposure and related hazards.
Background. Identification of potential hazards, their adverse health effects, and predisposing factors in the workplace are critical to improving safety. The objective of the study was to assess the knowledge of occupational hazards, the prevalence of perceived health problems and their predictors among textile dye workers in Abeokuta Nigeria who work in unsupervised settings.Materials and Methods. In this cross-sectional study, data were collected from 199 participants using a validated semi-structured interviewer-administered questionnaire. Multiple linear regression analysis was used to determine the predictors of knowledge while Pearson Chi-square was employed to test the association between perceived health problems, sociodemographics and work environment characteristics.Results. The mean age of the respondents was 40 (SD=12) years with an average work experience of 19 years. The majority of respondents 139 (69.8%) had lower than average scores on knowledge of 25 questions on chemical hazards. There was no correlation between knowledge score and work experience (P=0.492) or age (P=0.462) but the knowledge was significantly associated with exposure score (P=0.004), gender (P=0.002) and adherence to instructions on chemicals usage (P=0.041) after adjusting for safe practice. The most frequent health problems among the dye workers were respiratory disorders (53.8%), allergies (51.8%), and skin disorders (24.1%). Airborne gaseous pollutants from the mixing of chemicals were associated with allergies (P=0.045), circulatory (P=0.02) and skin disorders (P=0.049) while air-borne textile fiber/dye particles could predict allergies (P=0.028).Conclusions. Findings revealed that exposure, gender and adherence to instruction labels on dye/chemical containers could determine knowledge of chemical hazards while physical work environment characteristics could determine health problems.
6 August 2016 in International Journal of Environmental Monitoring and Analysis
An ideal educational setting should be serene and conducive for both learning and working. However, due to the erratic power supply in Nigeria coupled with increase in number of commercial outfits, there has been an upsurge in the proliferation of portable generators at institutional settings. Studies conducted on noise from portable generators and its effects on human health in institutional environment are sparse. Noise levels from exposure to portable generators and its perceived attendant effects was assessed in this study. Oladele Ajose building (OAB) was purposively selected for this pilot study based on the frequency of generator use and level of commercial activities. A semi structured questionnaire was used to elicit information from staff and students. Noise levels in decibels (dB) was measured in six selected location for eight weeks in the indoor and outdoor environment of the building, using a calibrated AEMC sound meter. Results were compared with WHO guideline limits. Mean noise level in the indoor and outdoor environment was 60.26±8.45dB and 58.15±4.53dB respectively. Reported health problems in the last six months prior the study include ear pains (68%), headache (46%), tiredness (60%) and tinnitus (34%). Occupants of OAB are exposed to noise from electric generator at levels exceeding WHO limit. There is a need to find an alternative way to power generation in institutional settings because of the threat noise from generators poses to the serene and conducive learning environment.
22 November 2022 in Environmental Monitoring and Assessment
This study investigated water and sanitary conditions of a typical faculty of Public Health building, University of Ibadan, Nigeria. A cross-sectional study was conducted and 108 consented students and staff members were interviewed using a semi-structured questionnaire. Fifteen (15) toilet facilities with 45 rooms were also observed using an observational checklist. Respondents’ age was 28.9±5.5 years, 63.0% were female, 92.6% were students and all participants had completed tertiary education. The main source of water supply into the building was piped water (85.2%) and 77.9% used it for flushing toilet. Only 22.2% reported that the water source is readily accessible all the time while 63.0% stated that the quantity of water available got depleted during the afternoon time. On-site observations revealed that 8 (53.4%) of the toilet facilities had inadequate water supply. Majority (81.5%) reported water closet as the main type of sanitary convenience in the building while the major shortcomings of the toilets mentioned were non-accessibility (88.9%) and shortage of water supply (77.8%). All (100%) of the toilet rooms observed had no severe odour while 2 (4.4%) of the toilet rooms had appreciable quantities of vectors breeding. About fifty-nine percent had good attitude towards the sanitary conveniences within the building and significantly, 75.0% of female respondents had good attitude compared to 25.0% of their male counterpart (p<0.05). Twelve (11.1%) respondents said they practiced handwashing with water and soap and none (0.0%) reported presence of signs that encourage good hygiene practices in the toilet. Wash hand basins was observed to be present and functional within all the 15 (100%) toilet facilities, water was present in 10 (66.7%) of the facilities while soap was absent in all the 15 (100%) facilities observed. Constant water supply should be sustained, handwashing materials and signs that encourage good hygiene practices should be provided within the toilets.