Benedict J. Heinen

Benedict J. Heinen

Auto-generated profile, based on publicly available information

Benedict J. Heinen

University of Bristol

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Earth and Planetary Science Letters
Verified
Journal Article
Open access
JDJames Drewitt
James Drewitt
MWMichael J. Walter
Michael J. Walter
HZHongluo Zhang
Hongluo Zhang
SMSorcha C. McMahon
Sorcha C. McMahon
DEDavid Edwards
David Edwards
AKAnnette K. Kleppe
Annette K. Kleppe

9 April 2020 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JDJames Drewitt
James Drewitt
FTFrancesco Turci
Francesco Turci
BHBenedict J. Heinen
Benedict J. Heinen
SMSimon G. Macleod
Simon G. Macleod
FQFei Qin
Fei Qin
OLOliver Lord
Oliver Lord
The atomic-scale structure, melting curve, and equation of state of liquid gallium has been measured to high pressure (p) and high temperature (T) up to 26 GPa and 900 K by in situ synchrotron x-ray diffraction. Ab initio molecular dynamics simulations up to 33.4 GPa and 1000 K are in excellent agreement with the experimental measurements, providing detailed insight at the level of pair distribution functions. The results reveal an absence of dimeric bonding in the liquid state and a continuous increase in average coordination number n¯GaGa from 10.4(2) at 0.1 GPa approaching ∼12 by 25 GPa. Topological cluster analysis of the simulation trajectories finds increasing fractions of fivefold symmetric and crystalline motifs at high p−T. Although the liquid progressively resembles a hard-sphere structure towards the melting curve, the deviation from this simple description remains large (≥40%) across all p−T space, with specific motifs of different geometries strongly correlating with low local two-body excess entropy at high p−T.

29 January 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
MLMarion Louvel
Marion Louvel
JDJames Drewitt
James Drewitt
ARAllan Ross
Allan Ross
RTRichard Thwaites
Richard Thwaites
BHBenedict J. Heinen
Benedict J. Heinen
SASimone Anzellini
Simone Anzellini
A new diamond-anvil cell apparatus for in situ synchrotron X-ray diffraction measurements of liquids and glasses, at pressures from ambient to 5 GPa and temperatures from ambient to 1300 K, is reported. This portable setup enables in situ monitoring of the melting of complex compounds and the determination of the structure and properties of melts under moderately high pressure and high temperature conditions relevant to industrial processes and magmatic processes in the Earth's crust and shallow mantle. The device was constructed according to a modified Bassett-type hydrothermal diamond-anvil cell design with a large angular opening (θ = 95°). This paper reports the successful application of this device to record in situ synchrotron X-ray diffraction of liquid Ga and synthetic PbSiO3 glass to 1100 K and 3 GPa.

3 May 2022 in Physics and Chemistry of Minerals
Verified
Journal Article
Open access
PDF file
BHBenedict J. Heinen
Benedict J. Heinen
JDJames W. E. Drewitt
James W. E. Drewitt
LiquidDiffract is an open source, Python-based graphical application for X-ray total scattering analysis of liquids and disordered solids. The software implements procedures to obtain information on macroscopic bulk properties and local atomic-scale structure of monatomic or polyatomic samples from X-ray total scattering data. LiquidDiffract provides an easy to use interface with tools to perform background subtraction; calculation, normalisation, and refinement of the reciprocal-space structure factor and real-space correlation functions; and the extraction of structural information such as bond lengths, coordination number, and bulk density. The software is well suited to investigations of amorphous materials at extreme conditions, such as studies of high-pressure melt structure, polyamorphic phase transitions, and liquid equations of state. The open-source distribution and graphical interface will be of particular benefit to researchers who are new to the field. In this article we describe the distribution, system requirements, and installation of LiquidDiffract, and detail the data processing workflow and underlying numerical methods.

1 June 2021 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
BHBenedict J. Heinen
Benedict J. Heinen
JDJames Drewitt
James Drewitt
MWMichael J. Walter
Michael J. Walter
CCCharles Clapham
Charles Clapham
FQFei Qin
Fei Qin
OLOliver Lord
Oliver Lord
High pressure–temperature experiments provide information on the phase diagrams and physical characteristics of matter at extreme conditions and offer a synthesis pathway for novel materials with useful properties. Experiments recreating the conditions of planetary interiors provide important constraints on the physical properties of constituent phases and are key to developing models of planetary processes and interpreting geophysical observations. The laser-heated diamond anvil cell (DAC) is currently the only technique capable of routinely accessing the Earth’s lower-mantle geotherm for experiments on non-metallic samples, but large temperature uncertainties and poor temperature stability limit the accuracy of measured data and prohibits analyses requiring long acquisition times. We have developed a novel internal resistive heating (IRH) technique for the DAC and demonstrate stable heating of non-metallic samples up to 3000 K and 64 GPa, as confirmed by in situ synchrotron x-ray diffraction and simultaneous spectroradiometric temperature measurement. The temperature generated in our IRH-DAC can be precisely controlled and is extremely stable, with less than 20 K variation over several hours without any user intervention, resulting in temperature uncertainties an order of magnitude smaller than those in typical laser-heating experiments. Our IRH-DAC design, with its simple geometry, provides a new and highly accessible tool for investigating materials at extreme conditions. It is well suited for the rapid collection of high-resolution P–V–T data, precise demarcation of phase boundaries, and experiments requiring long acquisition times at high temperature. Our IRH technique is ideally placed to exploit the move toward coherent nano-focused x-ray beams at next-generation synchrotron sources.

11 June 2025 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
JDJ. H. Davies
J. H. Davies
JPJ. Panton
J. Panton
IAI. Altoe
I. Altoe
MAM. Andersen
M. Andersen
PBP. Béguelin
P. Béguelin
JWJ. Wookey
J. Wookey
Mantle circulation in the Earth acts to remove heat from its interior and is thus a critical driver of our planet’s internal and surface evolution. Numerical mantle circulation models (MCMs) driven by plate motion history allow us to model relevant physical and chemical processes and help answer questions related to mantle properties and circulation. Predictions from MCMs can be tested using a variety of observations. Here, we illustrate how the combination of many disparate observations leads to constraints on mantle circulation across space and time. We present this approach by first describing the set-up of the example test MCM, including the parameterization of melting, and the methodology used to obtain elastic Earth models. We subsequently describe different constraints, that either provide information about present-day mantle (e.g. seismic velocity structure and surface deflection) or its temporal evolution (e.g. geomagnetic reversal frequency, geochemical isotope ratios and temperature of upper mantle sampled by lavas). We illustrate the information that each observation provides by applying it to a single MCM. In future work, we shall apply these observational constraints to a large number of MCMs, which will allow us to address questions related to Earth-like mantle circulation.