Daniel Y. Sze

Daniel Y. Sze

Auto-generated profile, based on publicly available information

Daniel Y. Sze

Division of Interventional Radiology, Stanford University, Stanford, California

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2022 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
MBMark O. Baerlocher
Mark O. Baerlocher
BNBoris Nikolic
Boris Nikolic
DSDaniel Y. Sze
Daniel Y. Sze

12 January 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
HLHugo Levillain
Hugo Levillain
OBOreste Bagni
Oreste Bagni
CDChristophe M. Deroose
Christophe M. Deroose
ADArnaud Dieudonné
Arnaud Dieudonné
SGSilvano Gnesin
Silvano Gnesin
PFPatrick Flamen
Patrick Flamen
Purpose: A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. Methods: A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%–79%, no agreement ≤ 49%). Results: Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100–120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). Conclusion: Practitioners are encouraged to work towards adoption of these recommendations.

1 December 2021 in Radiology
Verified
Journal Article
Closed access
Robbert S. PuijkRobbert S. Puijk
Robbert S. Puijk
MAMuneeb Ahmed
Muneeb Ahmed
AAAndreas Adam
Andreas Adam
YAYasuaki Arai
Yasuaki Arai
RARonald Arellano
Ronald Arellano
Martijn Ruben MeijerinkMartijn Ruben Meijerink
Martijn Ruben Meijerink
A panel of experts reached consensus on recommendations on when to assess oncologic outcomes per patient, per session, and per tumor; definitions of starting and ending times; definitions of surviv... There is currently no consensus regarding preferred clinical outcome measures following image-guided tumor ablation or clear definitions of oncologic end points. This consensus document proposes st...

1 April 2008 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
DSDaniel Y. Sze
Daniel Y. Sze
JKJeffrey S. Kao
Jeffrey S. Kao
JFJoan K. Frisoli
Joan K. Frisoli
SMStuart W. McCallum
Stuart W. McCallum
WKWilliam A. Kennedy
William A. Kennedy
MRMahmood K. Razavi
Mahmood K. Razavi

1 April 2009 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
DSDaniel Y. Sze
Daniel Y. Sze
MBMaurice A.A.J. van Den Bosch
Maurice A.A.J. van Den Bosch
MDMichael D. Dake
Michael D. Dake
DMD. Craig Miller
D. Craig Miller
LHLawrence V. Hofmann
Lawrence V. Hofmann
RMR. Scott Mitchell
R. Scott Mitchell
Background— Endoleaks after stent-graft repair of aortic dissections are poorly understood but seem substantially different from those seen after aneurysm repair. We studied anatomic and clinical factors associated with endoleaks in patients who underwent stent-graft repair of complicated type B aortic dissections. Methods and Results— From 2000 to 2007, 37 patients underwent stent-graft repair of acute (≤14 days; n=23), subacute (15 to 90 days; n=10) or chronic (>90 days; n=4) complicated type B aortic dissections using the Gore Thoracic Excluder (n=17) or TAG stent-grafts (n=20) under an investigator-sponsored protocol. Endoleaks were classified as imperfect proximal seal, flow through fenestrations or branches, or complex (both). Variables studied included coverage of the left subclavian artery, aortic curvature, completeness of proximal apposition, dissection chronicity, and device used. Endoleaks were found during follow-up (mean, 22 months) in 59% of patients, and they were associated with coverage of the left subclavian artery (complex, P<0.001), small radius of curvature (type 1 and complex, P=0.05), and greatest length of unapposed proximal stent graft (complex, P<0.0001). During follow-up, 10 endoleaks resolved spontaneously, 6 required reintervention for false lumen dilatation, and 2 were stable without clinical consequences. Conclusions— Endoleaks are common after stent-graft repair of aortic dissection and may lead to false lumen enlargement necessitating reintervention. Anatomic complexities such as acute aortic curvature and covered side branches were associated with endoleaks, illustrating the need for dissection-specific device development.

22 February 2013 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
MLMarnix G. E. H. Lam
Marnix G. E. H. Lam
SBSubhas Banerjee
Subhas Banerjee
JLJohn D. Louie
John D. Louie
MAMohamed H. K. Abdelmaksoud
Mohamed H. K. Abdelmaksoud
AIAndrei H. Iagaru
Andrei H. Iagaru
DSDaniel Y. Sze
Daniel Y. Sze