Kirubaveni Savarimuthu

Kirubaveni Savarimuthu

Auto-generated profile, based on publicly available information

Kirubaveni Savarimuthu

Department of Electronics and Communication Engineering, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2021 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
DPDevisowjanya Potti
Devisowjanya Potti
YTYarasi Tusharika
Yarasi Tusharika
GAGulam Nabi Alsath
Gulam Nabi Alsath
SKSavarimuthu Kirubaveni
Savarimuthu Kirubaveni
MKMalathi Kanagasabai
Malathi Kanagasabai
PBP. Balaji Bhargav
P. Balaji Bhargav
A novel optically transparent multiple-input multiple-output (MIMO) antenna for automotive applications is presented in this article. The MIMO antenna consists of a two-semicircular slot-loaded monopole with a staircase ground structure. It is developed on a glass substrate with dimension 29×50 mm 2 . The fluorine-doped tin oxide and indium-doped tin oxide (ITO) are used as the conductive layers on the bottom and top of the substrate with sheet resistance 4 Ω/sq and 10 Ω/sq, respectively. The fabricated antenna has an optical transmittance greater than 72%; hence, it can be placed on the glass surface of the automotive. The measured results show that the proposed antenna exhibits a good impedance matching over a frequency of 2.4-11 GHz with isolation greater than 20 dB and a peak realized gain of 2 dBi, which is suitable for ultrawideband (UWB) automotive applications.

10 December 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AVAruna Veeraselvam
Aruna Veeraselvam
GAGulam Nabi Alsath
Gulam Nabi Alsath
KSKirubaveni Savarimuthu
Kirubaveni Savarimuthu
PVPancha Durga Vijayaraman
Pancha Durga Vijayaraman
A novel multiband terahertz (THz) refractive index-based carcinoma sensor is designed and investigated in this paper. The proposed THz sensor is constructed using meandered sectoral stubs enclosed in a square loop. The proposed sensor has a footprint of 1.019 λeff× 1.019 λeff and operates at three distinct frequencies, viz. 1.095 THz, 2.865 THz, and 4.065 THz. The absorption characteristics of the sensor are analyzed to estimate the performance of the proposed sensor. The free space absorptivity is estimated as 99.6%, 99.1% and 99.2% at the said three resonant frequencies. The peak Q factor of 22.58 is realized at 4.065 THz under free space unloaded condition. Further, a study on different design parameters on absorption peaks and polarization independency is conducted and the results are presented. Followed by these, the sensitivity performance of the proposed carcinoma THz sensor is analyzed for healthy and cancerous cells of blood, skin and breast based on their unique refractive index profile. The peak sensitivity of 514.28 GHz/RIU at 2.865 THz, 476.35 GHz/RIU at 4.065 THz, and 476.91 GHz/RIU at 4.065 THz is theoretically observed for blood, skin and breast cancer cells respectively. Similarly, the high Q factor of 21.85, 18.06, 19.21 at 4.065 THz with FoM of 2.8, 2.38 and 2.384 are also observed for blood, skin and breast cancer respectively. Furthermore, the influence of the sample thickness on the THz sensor performance is analyzed. Thus, the proposed THz sensor is a promising entity for the detection and early diagnosis of cancer cells using THz radiation.

6 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AVAruna Veeraselvam
Aruna Veeraselvam
GAGulam Nabi Alsath
Gulam Nabi Alsath
KSKirubaveni Savarimuthu
Kirubaveni Savarimuthu
Jaume AngueraJaume Anguera
Jaume Anguera
JPJessica Constance Paul
Jessica Constance Paul
RKRam Kumar Krishnan
Ram Kumar Krishnan
In this paper, a graphene-based THz metamaterial has been designed and characterized for use in sensing various refractive index profiles. The proposed single-band THz sensor was constructed using a graphene-metal hybridized periodic metamaterial wherein the unit cell had a footprint of 1.395λeff × 1.395λeff and resonated at 4.4754 THz. The realized peak absorption was 98.88% at 4.4754 THz. The sensitivity of the proposed metamaterial sensor was estimated using the absorption characteristics of the unit cell. The performance of the sensor was analyzed under two different categories, viz. the random dielectric loading and chemical analytes, based on the refractive index. The proposed THz sensor offered a peak sensitivity of 22.75 GHz/Refractive Index Unit (RIU) for the various sample loadings. In addition, the effect of the sample thickness on the sensor performance was analyzed and the results were presented. From the results, it can be inferred that the proposed metamaterial THz sensor that was based on a refractive index is suitable for THz sensing applications.

14 September 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
AVAruna Veeraselvam
Aruna Veeraselvam
GAGulam Nabi Alsath
Gulam Nabi Alsath
KSKirubaveni Savarimuthu
Kirubaveni Savarimuthu
This study describes the design and characterization of a highly sensitive THz refractive index-based metamaterial sensor for the detection of biological samples. The proposed ultra-miniaturized THz sensor is constructed using a fan-shaped resonator enclosed within a square loop. The proposed sensor has a footprint of 0.353 $\lambda$ eff × 0.353 $\lambda$ eff where $\lambda$ eff is the wavelength calculated at the operating frequency of 4.87 THz. The sensitivity of the THz sensor is estimated using the absorption characteristics of the metamaterial. The estimated free space absorptivity is 99.9%. The proposed sensor is polarization insensitive due to the rotational symmetry and it is angularly stable up to 60°. The performance of the sensor is evaluated for different materials and biomedical samples. The results indicate that the proposed sensor has an average sensitivity of 1936 GHz/ Refractive Index Unit (RIU). Furthermore, the influence of the sample thickness is analysed, and the results are presented. From the results, it is inferred that the proposed THz sensor has a good Figure of Merit (FoM) and is suitable for chemical sensing, including the nucleic acids and other components present in the biological samples.

19 July 2018 in Nanoscale
Verified
Journal Article
Closed access
PDF file
KSKirubaveni Savarimuthu
Kirubaveni Savarimuthu
RSRadha Sankararajan
Radha Sankararajan
RGRajamanickam Govindaraj
Rajamanickam Govindaraj
SNSanthosh Narendhiran
Santhosh Narendhiran
Vibration based piezoelectric energy harvesting from unused ambient sources is an efficient approach for a battery-free, sustainable and green power source for self-powered electronics. This paper presents the performance enhancement of a p–n junction based flexible nano-generator (NG). A stable, non-hazardous spiro and zinc oxide (ZnO) p–n junction based NG is proposed. The device performance is compared with a Schottky contact based NG. The experimental study is carried out using the tip excitation method. Most importantly, the contact modification with spiro improves the performance of the device by five times, thereby yielding an open circuit voltage of 300 mV, a short-circuit current density of 220 μA cm−2 and a maximum power density up to 48 μW cm−2 at 0.5 N. Furthermore, performance enhancement is achieved by reducing the external screening and the internal impedance. The results are validated using an RC time constant value derived from the impedance analysis.

1 September 2017 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
KSKirubaveni Savarimuthu
Kirubaveni Savarimuthu
RSRadha Sankararajan
Radha Sankararajan
SMSudha Murugesan
Sudha Murugesan
This study presents the design of a piezoelectric vibration energy generator with power conditioning circuit to power CMOTE wireless sensor node. The test result shows that the energy harvester produces a maximum AC output voltage of 3 V with an optimal resistive load of 200 Ω for 1.5 m/s 2 acceleration at the resonant frequency of 275 Hz. The output power from the energy harvester is 65.9 mW. The characterisation analysis of energy harvester without tip mass and effect caused by the addition of mass at different positions have been analysed. Additional mass reduces the device frequency to 21.5 Hz and improves the output voltage up to 3.632 V. A single‐stage AC–DC power converter which integrates the rectification and boosting circuit is designed, simulated and implemented in hardware to extract the maximum power from harvester to attain higher efficiency. The designed circuit will operate at a minimum AC voltage of 0.5 V. The minimum output from the harvester is rectified, boosted to 7 V DC output and regulated to 3.3 V to power wireless sensor node. The conversion efficiency of the circuit is improved to 70.03% with reduced loss of 19.76 mW by size reduction.