Solid organ transplant recipients have attenuated immune responses to SARS-CoV-2 vaccines. In this study, we report on immune responses to 3rd- (V3) and 4th- (V4) doses of heterologous and homologous vaccines in a kidney transplant population. We undertook a single centre cohort study of 724 kidney transplant recipients prospectively screened for serological responses following 3 primary doses of a SARS-CoV2 vaccine. 322 patients were sampled post-V4 for anti-spike (anti-S), with 69 undergoing assessment of SARS-CoV-2 T-cell responses. All vaccine doses were received post-transplant, only mRNA vaccines were used for V3 and V4 dosing. All participants had serological testing performed post-V2 and at least once prior to their first dose of vaccine. 586/724 (80.9%) patients were infection-naïve post-V3; 141/2586 (24.1%) remained seronegative at 31 (21-51) days post-V3. Timing of vaccination in relation to transplantation, OR: 0.28 (0.15-0.54), p=0.0001; immunosuppression burden, OR: 0.22 (0.13-0.37), p<0.0001, and a diagnosis of diabetes, OR: 0.49 (0.32-0.75), p=0.001, remained independent risk factors for non-seroconversion. Seropositive patients post-V3 had greater anti-S if primed with BNT162b2 compared with ChAdOx1, p=0.001. Post-V4, 45/239 (18.8%) infection-naïve patients remained seronegative. De novo seroconversion post-V4 occurred in 15/60 (25.0%) patients. There was no difference in anti-S post-V4 by vaccine combination, p=0.50. T-cell responses were poor, with only 11/54 (20.4%) infection-naive patients having detectable T-cell responses post-V4, with no difference seen by vaccine type. A significant proportion of transplant recipients remain seronegative following 3- and 4- doses of SARS-CoV-2 vaccines, with poor T-cell responses, and are likely to have inadequate protection against infection. As such alternative strategies are required to provide protection to this vulnerable group. MW/PK received study support from Oxford Immunotec.
10 September 2022 in The Lancet Regional Health - Europe
People with end-stage kidney disease, including people on haemodialysis, are susceptible to greater COVID-19 related morbidity and mortality. This study compares the immunogenicity and clinical effectiveness of BNT162B2 versus ChAdOx1 in haemodialysis patients. In this observational cohort study, 1021 patients were followed-up from time of vaccination until December 2021. All patients underwent weekly RT-PCR screening. Patients were assessed for nucleocapsid(anti-NP) and spike(anti-S) antibodies at timepoints after second(V2) and third(V3) vaccinations. 191 patients were investigated for T-cell responses. Vaccine effectiveness (VE) for prevention of infection, hospitalisation and mortality was evaluated using the formula VE=(1-adjustedHR)x100. 45.7% (467/1021) had evidence of prior infection. There was no difference in the proportion of infection-naïve patients who seroconverted by vaccine type, but median anti-S antibody titres were higher post-BNT162b2 compared with ChAdOx1; 462(152-1171) and 78(20-213) BAU/ml respectively, p<0.001. Concomitant immunosuppressant use was a risk factor for non-response, OR 0.12[95% CI 0.05–0.25] p<0.001. Post-V3 (all BNT162b2), median anti-S antibody titres remained higher in those receiving BNT162b2 versus ChAdOx1 as primary doses; 2756(187–1246) and 1250(439–2635) BAU/ml respectively, p=0.003. Anti-S antibodies waned over time. Hierarchical levels of anti-S post-V2 predicted risk of infection; patients with no/low anti-S being at highest risk. VE for preventing infection, hospitalisation and death was 53% (95% CI 6–75), 77% (95% CI 30–92) and 93% (95% CI 59–99) respectively, with no difference seen by vaccine type. Serum anti-S concentrations predict risk of breakthrough infection. Anti-S responses vary dependent upon clinical features, infection history and vaccine type. Monitoring of serological responses may enable individualised approaches to vaccine boosters in at risk populations. National Institute for Health Research (NIHR) Biomedical Research Centre based at Imperial College Healthcare NHS Trust and Imperial College London.
Background: Lateral flow immunoassays (LFIAs) are able to achieve affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine. Methods: This was a prospective diagnostic accuracy study. Sampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Two cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following two doses of SARS-CoV-2 vaccine, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination and subsequent follow up. During the participants visit, finger-prick blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG was detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. A total of 186 paired samples were collected. The accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay Results: The LFIA had an estimated sensitivity of 92.0% (114/124; 95% confidence interval [CI] 85.7% to 96.1%) and specificity of 93.6% (58/62; 95% CI 84.3% to 98.2%) using the Abbott assay as reference standard (using the threshold for positivity of 7.10 BAU/ml) Conclusions: Fortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveillance but does not meet criteria for individual testing.
Background: Lateral flow immunoassays (LFIAs) are able to achieve affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine. Methods: This was a prospective diagnostic accuracy study. Sampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Two cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following two doses of SARS-CoV-2 vaccine, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination and subsequent follow up. During the participants visit, finger-prick blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG was detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. A total of 186 paired samples were collected. The accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay Results: The LFIA had an estimated sensitivity of 92.0% (114/124; 95% confidence interval [CI] 85.7% to 96.1%) and specificity of 93.6% (58/62; 95% CI 84.3% to 98.2%) using the Abbott assay as reference standard (using the threshold for positivity of 7.10 BAU/ml) Conclusions: Fortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveillance but does not meet criteria for individual testing.
Leading young researchers describe their current patient-centred research from epidemiological, immunological and psychological perspectives Schedule:1. 13:30-14:00 Dialysis After Graft Loss - Survival Factors 2. 14:00-14:30 Dialysis After Graft Loss - Immune Injury 3. 14:30-15:00 Patient Related Outcomes with HaemodiafiltrationDialysis After Graft Loss - Survival FactorsKidney transplant failure contributes to a considerable proportion of new dialysis starters. In some centres there are dedicated clinics for patients with failing kidney transplants, however, the specific needs of patients with dialysis after graft loss (DAGL) may be lost in the non-specific clinical review practiced in the general dialysis community. This talk examines the mortality and morbidity risk in patients returning with DAGL. We will discuss the epidemiology of patients returning to dialysis after graft loss to identify areas of concern in management that warrant a more specialised approach.Dialysis After Graft Loss- Immune HarmAdvancements in clinical practices and improved management of chronic conditions have resulted in kidney transplant recipients living longer, which has caused a rise in patients returning to dialysis after graft failure and being waitlisted for re-transplantation. Additionally, there has been an increase in the use of deceased donor organs in transplantation. Most patients who return to dialysis after graft failure are taking at least one immunosuppression medication, which can lead to increased morbidity and mortality with prolonged use. However, balancing the risk of withdrawal of these medications with the risk of sensitisation for future transplantation is crucial. Therefore, patient selection and timing of relisting should be approached with an individualised and tailored approach to immunosuppression regimes.New Developments in Patient-Reported Outcomes with Results for Use in Person-Centered Kidney CareThe presentation will introduce how a current, structured, science-based patient-reported outcomes questionnaire look like, what its uses are, and how to recognize well-designed questionnaires beyond legacy instruments such as the KDQOL. Examples from recent studies such as the CONVINCE trial on hemodiafiltration will be presented showing new results that demonstrate their benefits in making treatment gaps and improvements visible from the perspective of the patient. There will also be an outlook into new developments of electronic patient-reported outcomes, including computer-adaptive testing using item-response theory that allows for interactive questionnaires that aim to reduce response burden and increase information content.