Katrine Uhrbrand

Katrine Uhrbrand

Auto-generated profile, based on publicly available information

Katrine Uhrbrand

National Research Centre for the Working Environment, Lersø Parkallé 105, DK-2100, Copenhagen, Denmark

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Water Research
Verified
Journal Article
Closed access
KUK. Uhrbrand
K. Uhrbrand
ASA.C. Schultz
A.C. Schultz
AKAntti Koivisto
Antti Koivisto
UNU. Nielsen
U. Nielsen
AMAnne Mette Madsen
Anne Mette Madsen

1 June 2019 in Science of The Total Environment
Verified
Journal Article
Open access
AKAntti Koivisto
Antti Koivisto
KKKirsten Inga Kling
Kirsten Inga Kling
Otto HanninenOtto Hanninen
Otto Hanninen
MJMichael Jayjock
Michael Jayjock
JLJakob Löndahl
Jakob Löndahl
THTareq Hussein
Tareq Hussein
Poor air quality is a leading contributor to the global disease burden and total number of deaths worldwide. Humans spend most of their time in built environments where the majority of the inhalation exposure occurs. Indoor Air Quality (IAQ) is challenged by outdoor air pollution entering indoors through ventilation and infiltration and by indoor emission sources. The aim of this study was to understand the current knowledge level and gaps regarding effective approaches to improve IAQ. Emission regulations currently focus on outdoor emissions, whereas quantitative understanding of emissions from indoor sources is generally lacking. Therefore, specific indoor sources need to be identified, characterized, and quantified according to their environmental and human health impact. The emission sources should be stored in terms of relevant metrics and statistics in an easily accessible format that is applicable for source specific exposure assessment by using mathematical mass balance modelings. This forms a foundation for comprehensive risk assessment and efficient interventions. For such a general exposure assessment model we need 1) systematic methods for indoor aerosol emission source assessment, 2) source emission documentation in terms of relevant a) aerosol metrics and b) biological metrics, 3) default model parameterization for predictive exposure modeling, 4) other needs related to aerosol characterization techniques and modeling methods. Such a general exposure assessment model can be applicable for private, public, and occupational indoor exposure assessment, making it a valuable tool for public health professionals, product safety designers, industrial hygienists, building scientists, and environmental consultants working in the field of IAQ and health.

20 April 2016 in Annals of Occupational Hygiene
Verified
Journal Article
Open access
PDF file
AMAnne Mette Madsen
Anne Mette Madsen
TATaif Alwan
Taif Alwan
AØAnders Ørberg
Anders Ørberg
KUKatrine Uhrbrand
Katrine Uhrbrand
MJMarie Birk Jørgensen
Marie Birk Jørgensen
A large number of people work with garbage collection, and exposure to microorganisms is considered an occupational health problem. However, knowledge on microbial exposure at species level is limited. The aim of the study was to achieve knowledge on waste collectors’ exposure to airborne inhalable fungal and bacterial species during waste collection with focus on the transport of airborne microorganisms into the truck cab. Airborne microorganisms were collected with samplers mounted in the truck cab, on the workers’ clothes, and outdoors. Fungal and bacterial species were quantified and identified. The study showed that the workers were exposed to between 112 and 4.8×104 bacteria m−3 air and 326 and 4.6×104 fungi m−3 air. The personal exposures to bacteria and fungi were significantly higher than the concentrations measured in the truck cabs and in the outdoor references. On average, the fungal and bacterial concentrations in truck cabs were 111 and 7.7 times higher than outdoor reference measurements. In total, 23 fungal and 38 bacterial species were found and identified. Most fungal species belonged to the genus Penicillium and in total 11 Penicillium species were found. Identical fungal species were often found both in a personal sample and in the same person’s truck cab, but concentrations were on average 27 times higher in personal samples. Concentrations of fungal and bacterial species found only in the personal samples were lower than concentrations of species also found in truck cabs. Skin-related bacteria constituted a large fraction of bacterial isolates found in personal and truck cab samples. In total, six Staphylococcus species were found. In outdoor samples, no skin-related bacteria were found. On average, concentrations of bacterial species found both in the truck cab and personal samples were 77 times higher in personal samples than in truck cab samples. In conclusion, high concentrations of fungi were found in truck cabs, but the highest concentrations were found in personal samples; fungal and bacterial species found in high concentrations in personal samples were also found in truck cabs, but in lower concentrations indicating that both fungi and bacteria are transported by the workers into the truck cab, and are subsequently aerosolized in the truck cab.

16 October 2011 in Food and Environmental Virology
Verified
Journal Article
Closed access
PDF file
KUKatrine Uhrbrand
Katrine Uhrbrand
ASAnna Charlotte Schultz
Anna Charlotte Schultz
AMAnne Mette Madsen
Anne Mette Madsen

1 December 2020 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
RLRui Lu
Rui Lu
MFMargit W. Frederiksen
Margit W. Frederiksen
KUKatrine Uhrbrand
Katrine Uhrbrand
YLYanpeng Li
Yanpeng Li
CØClaus Østergaard
Claus Østergaard
AMAnne Mette Madsen
Anne Mette Madsen
Work in wastewater treatment plants (WWTPs) can be associated with respiratory symptoms and diarrhea. The aim of this study was to obtain knowledge about WWTP workers' exposure to airborne bacteria and endotoxin, and the inflammatory potential (TIP) of their exposure, and to evaluate the risk posed by the exposure by 1) calculating a hazard index and relating the exposure to suggested occupational exposure limits (OELs), 2) estimating the potential deposition of bacteria in the airways, 3) relating it to the risk group classification of bacteria by the European Union, and 4) estimating the TIP of the personal exposure. A cohort of 14 workers were followed over one year. Bioaerosols were collected using personal and stationary samplers in a grid chamber house and an aeration tank area. Airborne bacteria were identified using (MALDI-TOF MS), and TIP of exposure was measured using HL-60 cells. A significant effect of season, work task, and person was found on the personal exposure. A hazard index based on exposure levels indicates that the risk caused by inhalation is low. In relation to suggested OELs, 14% and 34% of the personal exposure were exceeded for endotoxin (≥50 EU/m3) and bacteria (≥500 CFU/m3). At least 70% of the airborne bacteria in the grid chamber house and the aeration tank area could potentially deposit in the lower respiratory tract. From the personal samples, three of 131 bacterial species, Enterobacter cloacae, Staphylococcus aureus, and Yersinia enterocolitica are classified within Risk Group 2. Seven additional bacteria from the stationary samples belong to Risk Group 2. The bacterial species composition was affected significantly by season (p = 0.014) and by sampling type/area (p = 0.001). The TIP of WWTP workers' exposure was higher than of a reference sample, and the highest TIP was measured in autumn. TIP of personal exposure correlated with bacterial exposure. Based on the geometric average exposures to endotoxin (9.2 EU/m3) and bacteria (299 CFU/m3) and based on the calculated hazard index, the risk associated with exposure is low. However, since 43 of 106 exposure levels exceed suggested OELs, the TIP of exposure was elevated and associated with bacterial exposure, and WWTP workers were exposed to pathogenic bacteria, a continued focus on preventive measures is important. The identification of bacteria to species level in personal samples was necessary in the risk assessment, and measurement of the microbial composition made the source tracking possible.

1 October 2010 in Journal of Virological Methods
Verified
Journal Article
Closed access
KUKatrine Uhrbrand
Katrine Uhrbrand
MMMette Myrmel
Mette Myrmel
LMLeena Maunula
Leena Maunula
KVKirsti Vainio
Kirsti Vainio
RTRamona Trebbien
Ramona Trebbien
ASAnna Charlotte Schultz
Anna Charlotte Schultz