This article proposes a novel type of the 2nd and 4th harmonic torque suppression methods during conventional single-phase open-circuit fault-tolerant operation when considering the 3rd harmonic back-EMF of permanent magnet synchronous motor (PMSM). These suppression methods are based on injecting the 3rd harmonic currents into the two remaining healthy phases, which produces harmonic torque of opposite phase to cancel the original one. The suppression can have three different constraints: maintaining the average torque, eliminating the 2nd harmonic torque, and eliminating the 4th harmonic torque. They cannot be achieved simultaneously. Combining any two of them leads to a particular injection method. Three particular methods are developed and their performance are investigated by theoretical analysis and compared against the conventional one. The proposed fault tolerant control strategies are applicable to various fault-tolerant inverter topologies by using these novel phase current references, whereas the current tracking algorithms could be different. To ease validation, a four-leg inverter topology is selected to implement such injection methods to a three-phase star-connected 10-pole/9-slot PMSM. The experiments validate that tracking the proposed current references can effectively suppress the harmonic torque, which confirms the theoretical analysis.
22 June 2020 in IEEE Transactions on Industry Applications
This paper proposes adaptive torque ripple suppression methods by utilizing resonant controllers during single-phase open-circuit fault-tolerant operation of three-phase star-connected permanent magnet synchronous motor (PMSM). A zero sequence current is supposed to be injected to maintain the post-fault torque same as pre-fault torque. According to post-fault PMSM model, feedforward voltage compensation can be adopted to inject the zero sequence current and hence attenuate the post-fault speed and torque ripples in vector control framework. However, the feedforward voltage compensation which is related to phase resistance and leakage inductance may be inaccurate due to temperature variation, etc., and hence an unexpected 2nd harmonic torque ripple still exists. In this paper, adaptive suppression methods of the 2nd harmonic torque are proposed: the first one constructs a novel closed current loop of zero axis and the second one modifies the controllers in dq axis current loop. These methods are based on resonant controllers which can adaptively compensate the voltage needed for the zero sequence current injection. Experiments are implemented based on a four-leg inverter, and the performance comparison between feedforward compensation and adaptive compensation validate that the proposed methods can effectively suppress the post-fault torque and speed ripple.