Objectives: Hemoglobin (Hb) variant is one of the most common monogenic inherited disorders. We aimed to explore the prevalence and hematological and molecular characteristics of Hb variants in southern China. Methods: We collected blood samples from all patients with suspected variants found during HbA1c measurement via a cation-exchange high-performance liquid chromatography system (Bio-Rad Variant II Turbo 2.0) or a capillary electrophoresis method (Sebia Capillarys). Hematological analysis, Sanger sequencing, and gap-PCR were performed for these samples. Results: Among the 311,024 patients tested, we found 1,074 Hb variant carriers, including 823 identified using Capillarys and 251 using Variant II Turbo 2.0, with a total carrier rate of 0.35%. We discovered 117 types of Hb variants (52 HBB, 47 HBA, and 18 HBD mutations) containing 18 new mutations. The most common variant found was Hb E, followed by Hb New York, Hb J-Bangkok, Hb Q-Thailand, Hb G-Coushatta, Hb G-Honolulu, Hb G-Taipei, and Hb Broomhill. Most heterozygotes for the Hb variant exhibited normal hematological parameters. However, most patients with compound heterozygotes for the Hb variant and thalassemia showed varied degrees of microcytic hypochromic anemia. Conclusions: The prevalence of hemoglobin variants remains high and exhibits genetic diversity and widespread distribution in the population of southern China.
Background: Glycated hemoglobin, or hemoglobin A1c (HbA1c), serves as a crucial marker for diagnosing diabetes and monitoring its progression. We aimed to assess the interference posed by common Hb variants on popular HbA1c measurement systems. Methods: A total of 63 variant and nonvariant samples with target values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-calibrated methods were included. We assessed 6 methods for measuring HbA1c in the presence of HbS, HbC, HbD, HbE, and fetal hemoglobin (HbF): 2 cation-exchange high-performance liquid chromatography (HPLC) methods (Bio-Rad D-100 and HLC-723 G8), a capillary electrophoresis (CE) method (Sebia Capillarys 3 TERA), an immunoassay (Roche c501), an enzyme assay system (Mindray BS-600M), and a boronate affinity method (Primus Premier Hb9210). Results: The HbA1c results for nonvariant samples from the 6 methods were in good agreement with the IFCC-calibrated method results. The Bio-Rad D-100, Capillarys 3, Mindray BS-600M, Premier Hb9210, and Roche c501 showed no interference from HbS, HbC, HbD, and HbE. Clinically significant interference was observed for the HLC-723 G8 standard mode. Elevated HbF levels caused significant negative biases for all 6 methods, which increased with increasing HbF concentration. Conclusion: Elevated levels of HbF can severely affect HbA1c measurements by borate affinity, immunoassays, and enzyme assays.
1 April 2021 in American Journal of Clinical Pathology
Objectives: The present study was conducted to evaluate the usefulness of capillary electrophoresis (CE), cation-exchange high-performance liquid chromatography (HPLC), and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) for the screening of hemoglobin (Hb) variants prevalent in southern China. Methods: A total of 102 types of Hb variants in 1,083 variant carriers were identified over a 5-year period. These variants were analyzed by a CE method (Capillarys 3 TERA), a cation-exchange HPLC analyzer (Variant II Turbo 2.0), and a MALDI-TOF MS system (QuanTOF). Results: The presence of 85 (83.3%, 85/102), 84 (82.4%, 84/102), and 62 (60.8%, 62/102) Hb variants was detected by Capillarys 3 TERA, Variant II Turbo 2.0, and QuanTOF, respectively. Of the three methods, only Capillarys 3 TERA recognized all 10 of the most frequent Hb variants in southern China. There were six, two, and three Hb variants that can only be detected by Capillarys 3 TERA, Variant II Turbo 2.0, and QuanTOF, respectively. The detection limit of mass difference for QuanTOF was approximately 11 to 20 Da. Conclusions: MALDI-TOF MS is suitable for use as an auxiliary method rather than a stand-alone method for the screening of Hb variants prevalent in southern China.
28 June 2020 in Scandinavian Journal of Clinical and Laboratory Investigation
Structural hemoglobin (Hb) variant is generally caused by a point mutation in the globin gene that produces one amino acid substitution. Here, we describe a new α-chain variant found during HbA1c measurement. HbA1c procedures based on both ion-exchange high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) techniques failed to identify its presence. In contrast, MALDI-TOF mass spectrometry (MS) revealed the existence of a variant α-chain with a mass of 15155 Da. In addition, the Hb variant interfered with HbA1c determined by Bio-Rad D100. DNA sequencing confirmed the occurrence of a new heterozygous mutation [HBA1:C.182A→G] at codon 60, resulting in a coding change from lysine to arginine. We named it Hb Liuzhou for thde birthplace of the patient. This case exemplified that MALDI-TOF mass spectrometry can serve as the method of choice to identify and quantify the Hb variant.
17 July 2020 in Clinical Chemistry and Laboratory Medicine (CCLM)
Objectives: Hemoglobin (Hb) variants remain an important cause of erroneous HbA1c results. We present an approach to overcome the interference of Hb variants on HbA1c measurements using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Methods: Samples containing or not containing Hb variants were analyzed for HbA1c using an MALDI-TOF MS system (QuanTOF) and a boronate affinity comparative method (Ultra2). For QuanTOF, two sets of HbA1c values were obtained through α- and β-chain glycation. Results: A robust correlation between the glycation degrees of the α- and β-chains was found, and HbA1c values derived from α- and β-chain glycation correlated well with the Ultra2 results. Statistically significant differences (p<0.01) were found for all the Hb variants tested. When using the conventional β-chain glycation to determine HbA1c, clinically significant differences were only found among samples containing β-chain variants detected by QuanTOF (i.e., Hb J-Bangkok, Hb G-Coushatta, and Hb G-Taipei). In contrast, based on α-chain glycation, no clinically significant differences were found for these three variants. Conclusions: In addition to conventional β-chain glycation, α-chain glycation can be used to calculate HbA1c values. The interference of Hb variants on HbA1c quantification can be overcome by employing the glycation of the globin chain without a genetic variant to estimate HbA1c values.