Fang Shi

Fang Shi

Auto-generated profile, based on publicly available information

Fang Shi

Jet Propulsion Lab. (United States)

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2021
Verified
Conference Paper
Closed access
IPIlya Y. Poberezhskiy
Ilya Y. Poberezhskiy
TLTom Luchik
Tom Luchik
FZFeng Zhao
Feng Zhao
MFMargaret Frerking
Margaret Frerking
SBScott Basinger
Scott Basinger
HTHong Tang
Hong Tang
SPIE Digital Library Proceedings

28 July 2000
Verified
Conference Paper
Closed access
PDF file
DRDavid C. Redding
David C. Redding
SBScott A. Basinger
Scott A. Basinger
DCDavid Cohen
David Cohen
ALAndrew E. Lowman
Andrew E. Lowman
FSFang Shi
Fang Shi
MWMark E. Wilson
Mark E. Wilson
By segmenting and folding the primary mirror, quite large telescopes can be packed into the nose cone of a rocket. Deployed after launch, initial optical performance can be quite poor, due to deployment errors, thermal deformation, fabrication errors and other causes. We describe an automatic control system for capturing, aligning, phasing, and deforming the optics of such a telescope, going from initial cm-level wavefront errors to diffraction-limited observatory operations. This system was developed for the Next Generation Space Telescope and is being tested on the NGST Wavefront Control Testbed.


27 August 2024 in Geoenergy Science and Engineering
Verified
Journal Article
Closed access
FSFang Shi
Fang Shi
HLHualin Liao
Hualin Liao
FQFengtao Qu
Fengtao Qu
JLJiansheng Liu
Jiansheng Liu
TWTianyu Wu
Tianyu Wu

16 September 2015
Verified
Conference Paper
Closed access
PDF file
XWXu Wang
Xu Wang
JWJ Kent Wallace
J Kent Wallace
FSFang Shi
Fang Shi
WFIRST-AFTA design makes use of an existing 2.4m telescope for direct imaging of exoplanets. To maintain the high contrast needed for the coronagraph, wavefront error (WFE) of the optical system needs to be continuously sensed and controlled. Low Order Wavefront Sensing (LOWFS) uses the rejected starlight from an immediate focal plane to sense wavefront changes (mostly thermally induced low order WFE) by combining the LOWFS mask (a phase plate located at the small center region with reflective layer) with the starlight rejection masks, i.e. Hybrid Lyot Coronagraph (HLC)’s occulter or Shaped Pupil Coronagraph (SPC)’s field stop. Zernike wavefront sensor (ZWFS) measures phase via the phase-contrast method and is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIST/AFTA for its good sensitivity, accuracy, and its easy integration with the starlight rejection mask. In this paper, we review the theory of ZWFS operation, describe the ZWFS algorithm development, and summarize various numerical sensitivity studies on the sensor performance. In the end, the predicted sensor performance on SPC and HLC configurations are presented.

26 August 2004 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Closed access
YCYing-Xu Chen
Ying-Xu Chen
JYJun Yin
Jun Yin
KWKai-Xiong Wang
Kai-Xiong Wang
SFShi Fang
Shi Fang
A systematic study on the transient behavior of odor treatment using biofilters is described. The biofilters were exposed to variations in contaminant loading and periods of nonuse. Two bench-scale biofilters with different filter media were used. Mixtures of compost/perlite (5:1) and dry sludge/granular active carbon (5:1) were used as filter media. Ammonia (NH3), one of the main malodorous gases, was used as the target compound. The response of each biofilter to variations in contaminant mass loading, periodic nonuse, water content, and inlet concentration pulse was studied. The nonuse period comprised of two stages: the “idle phase” when no air was passing through the biofilters, and the “no-contaminant-loading phase” when only humidified air was passing through the biofilters. Concentration spike was applied to study the effects of shock loading on the biofilter performance. Biofilters responded effectively to NH3 concentration variations and shock loading by rapidly recovering to the original removal rates within 6–12 h. The results indicated re-acclimation times ranged from several hours to longer than a day. Longer idle phase produced longer re-acclimation periods than periods of no contaminant loading. When the media was dried during the biofiltration process, elimination capacity dropped accordingly for both biofilters. After 24 h of drying, the biofilter experiment could be restarted and run for a few days for recovering.