Tuqa Ghani Tregi

Tuqa Ghani Tregi

Auto-generated profile, based on publicly available information

Tuqa Ghani Tregi

University of Thi-Qar, Iraq

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2025 in Mesopotamian Journal of CyberSecurity
Verified
Journal Article
Open access
PDF file
TTTuqa Ghani Tregi
Tuqa Ghani Tregi
Mishall Hammed Al-ZubaidieMishall Hammed Al-Zubaidie
Mishall Hammed Al-Zubaidie
Securing big data in power plants is an important and fundamental step in the infrastructure of smart cities. In addition, it becomes a barrier if it is not controlled from the beginning. Security must be a combination of fast and robust properties. This research presents a traffic security system (TSS) in a smart city (SC). It is a novel paradigm meant to improve data security and integrity by means of a multilayered method. Advanced fault analysis, dual-stage pseudonymizing, quantum key distribution via the BB84 protocol, and Falcon signatures (FS) are combined in the proposed system. TSS enhances data security by enhancing privacy, supporting resilience against quantum computing threats, and not burdening the network with complex and large keys. The proposed system has been tested against several recently known attacks, such as replay, supply chain, Sybil, blackhole, eavesdropping, advanced persistent threat (APT), tampering, ransomware identity fraud, and desynchronization, and it has been proven to overcome them. In terms of performance evaluation, the average signing time was approximately 0.002 milliseconds. In comparison, the average signature verification time was approximately 0.004 milliseconds, with an average execution time of approximately 0.54 milliseconds and a precision of approximately 93.6 %, a recall of approximately 97.8 %, and an F1_score of approximately 95.6 %, which are considered low compared with those of state-of-the-art research. Thus, the proposed TSS system is highly acceptable for power plant applications. This work lays the groundwork for future developments in safe, privacy-conscious urban systems by presenting a multilayered approach to secure energy data in smart cities.

7 November 2025 in Applied Data Science and Analysis
Verified
Journal Article
Open access
PDF file
Mishall Hammed Al-ZubaidieMishall Hammed Al-Zubaidie
Mishall Hammed Al-Zubaidie
TTTuqa Ghani Tregi
Tuqa Ghani Tregi
The rapid progress of quantum computing poses significant challenges to traditional cryptographic mechanisms, necessitating the adoption of post-quantum cryptography (PQC) solutions. This paper proposes a Quantum-Enhanced Security for Smart Meters (QESM) system to protect power plant data in smart cities, integrating Kyber for secure key exchange, FALCON (Fast-Fourier Transform over Lattice-based Cryptography) for quantum-resistant digital signatures, and ZKP (Zero-Knowledge Proof) for effective verification without revealing sensitive data to secure power plant data against quantum attacks. To evaluate the security of the proposed system, we analyze its resistance to various quantum threats, including Shor’s algorithm, Grover’s algorithm, quantum key analysis, quantum reversal encryption, quantum amplification, quantum switching, and quantum collision attacks. In the current study, accurate measures were used and the average was approximately 7.065 (bits/byte) for randomness, the average execution time was 6.202 milliseconds, the average memory consumption was approximately 4.343 KB, 6.4 Completeness was equal to 1 and unforgeability was 100%. As for the average throughput, it was approximately 485,605 operations per second. That shows the QESM system provides strong security and efficiency, making it a viable solution for protecting the electricity infrastructure in smart cities in the quantum era.

29 August 2025
Verified
Book Chapter
Closed access
Mishall Hammed Al-ZubaidieMishall Hammed Al-Zubaidie
Mishall Hammed Al-Zubaidie
TTTuqa Ghani Tregi
Tuqa Ghani Tregi
The rapid advancement of quantum computing poses significant challenges to conventional cryptography, necessitating the adoption of post-quantum cryptography (PQC) solutions. This chapter proposes a Post-Quantum Lattice Security (PQLS) system for protecting power plant data in smart cities. It integrates Kyber for secure key exchange, Falcon for quantum-resistant digital signatures, ZKP for efficient authentication without revealing sensitive data, and JSON-LD for standardizing the format of data received from different smart meters. To evaluate the security of the proposed framework, we analyze its resistance to various threats, such as side-channel and message recovery attacks. We measured key performance indicators. The results showed an average CPU utilization of 2.4592 MS, memory consumption averaging 1843.899 KB, an execution time of 2.45 MS, and a level averaging 66.27677. This demonstrates that our proposed system offers high security and efficiency, making it a practical solution for protecting electrical infrastructure in smart cities in the quantum era.

5 December 2025
Verified
Book Chapter
Closed access
Mishall Hammed Al-ZubaidieMishall Hammed Al-Zubaidie
Mishall Hammed Al-Zubaidie
TTTuqa Ghani Tregi
Tuqa Ghani Tregi
This chapter attempts to present a Post-Quantum Secure Smart City Electricity Data (PQSED) system, which generates a quantum key via the BB84 protocol and digitally signs the data using FALCON, and uses pseudonym technology to add more security and protection to the data and digital signature, and also uses Walrus Optimization Algorithm (WOA) technology to the data to detect any abnormal behavior. The proposed system has been tested against several recently known attacks, such as replay attacks, Sybil attacks, eavesdropping, advanced ransomware attacks, social engineering attacks, and critical infrastructure attacks, and it has been proven to overcome them. In terms of performance evaluation, we obtained an average signature time of about 0.004 MS, an average signature verification time of about 0.006 MS, an average execution time of 0.66 MS, a precision of 96%, a recall of 95%, and an F1-score of 96%, which are good compared to the state-of-the-art research. Thus, our proposed system is highly acceptable for power plant applications.