Pengfei Xie

Pengfei Xie

Auto-generated profile, based on publicly available information

Pengfei Xie

Department of Electrical and Computer Engineering, Rutgers University, Piscataway, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
NSNaixin Song
Naixin Song
PXPengfei Xie
Pengfei Xie
WSWen Shen
Wen Shen
HOHanju Oh
Hanju Oh
YZYejia Zhang
Yejia Zhang
MAMark G. Allen
Mark G. Allen
Impedance-based protein detection sensors for point-of-care diagnostics require quantitative specificity, as well as rapid or real-time operation. Furthermore, microfabrication of these sensors can lead to the formation of factors suitable for in vivo operation. Herein, we present microfabricated needle-shaped microwell impedance sensors for rapid-sample-to-answer, label-free detection of cytokines, and other biomarkers. The microneedle form factor allows sensors to be utilized in transcutaneous or transvascular sensing applications. In vitro, experimental characterization confirmed sensor specificity and sensitivity to multiple proteins of interest. Mechanical characterization demonstrated sufficient microneedle robustness for transcutaneous insertion, as well as preserved sensor function postinsertion. We further utilized these sensors to carry out real-time in vivo quantification of human interleukin 8 (hIL8) concentration levels in the blood of transgenic mice that endogenously express hIL8. To assess sensor functionality, hIL8 concentration levels in serum samples from the same mice were quantified by ELISA. Excellent agreement between real-time in vivo sensor readings in blood and subsequent ELISA serum assays was observed over multiple transgenic mice expressing hIL8 concentrations from 62 pg/mL to 539 ng/mL.

2 July 2021 in Science Advances
Verified
Journal Article
Open access
PDF file
SMSeyed Reza Mahmoodi
Seyed Reza Mahmoodi
PXPengfei Xie
Pengfei Xie
DZDaniel P. Zachs
Daniel P. Zachs
EPErik J. Peterson
Erik J. Peterson
RGRachel S. Graham
Rachel S. Graham
MJMehdi Javanmard
Mehdi Javanmard
Single-step label-free nanowell array immunoassay accurately detects serum stress hormones within minutes at small volumes.

1 September 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
AGAzam Gholizadeh
Azam Gholizadeh
SASiamak Abbaslou
Siamak Abbaslou
PXPengfei Xie
Pengfei Xie
AKAra Knaian
Ara Knaian
MJMehdi Javanmard
Mehdi Javanmard

1 January 2018
Verified
Conference Paper
Closed access
JSJianye Sui
Jianye Sui
PXPengfei Xie
Pengfei Xie
ZLZhongtian Lin
Zhongtian Lin
MJMehdi Javanmard
Mehdi Javanmard
Electronically barcoded micro-particles have been demonstrated for use in various multiplexed molecular biomarker assays. Traditional optical and plasmonic methods for barcoding are capable of high throughput and high sensitivity, but require bulky instrumentation for readout, which cannot be easily made into a portable device. Previously, we reported a novel impedance based barcoding technique by fabricating tunable nano-capacitors on micro-particle surfaces thus modulating the overall particle impedance. In this work, we expand the library of barcoded particles using atomic layer deposited oxides of varying thickness and dielectric permittivity and study the effect of thickness and dielectric permittivity using multi-frequency impedance flow cytometry and utilize machine learning to classify different particle barcodes.