13 December 2024 in Science Advances
A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.
11 January 2023 in IEEE Transactions on Instrumentation and Measurement
Nitrogen-Vacancy (NV) center-based magnetometers have progressed from proof-of-concept demonstrations to table-top and compact devices as a consequence of global focus on developing commercially viable solutions. Although the magnetometer’s sensor head has been shrunk, the platform’s electronics/ test equipment form-factor and requirements continue to be a significant barrier to the creation of low-cost solutions. As a result, the usability and accessibility of an NV-based magnetometer are constrained. In order to reduce sensor size, overall power consumption, and accessibility, we have developed a method based on the Fast Fourier Transform (FFT) to detect optically detected magnetic resonance in an ensemble of NV centers without the usage of cumbersome and expensive bench-top equipment like lock-in amplifier. We perform a detailed comparative study of this protocol with the existing methods used for magnetic field sensing. We use this methodology to report a sensitivity of 126 nT/ √ Hz with the goal of developing protocols for low-cost magnetometry, making the magnetometer accessible with minimal components and laboratory setup and serving as an easy way to teach enthusiasts even at the undergraduate level.
8 July 2024 in Physical Review Applied
Quantum diamond microscopy using nitrogen-vacancy (-V) defects in diamond crystals has enabled the magnetic field imaging of a wide variety of nanoscale current profiles. Intimately linked with the imaging process is the problem of reconstructing the current density, which provides critical insight into the structure under study. This manifests as a nontrivial inverse problem of current reconstruction from noisy data, typically conducted via Fourier-based approaches. Learning algorithms and Bayesian methods have been proposed as novel alternatives for inference-based reconstructions. We study the applicability of Fourier-based and Bayesian methods for reconstructing two-dimensional current density maps from magnetic field images obtained from -V imaging. We discuss extensive numerical simulations to elucidate the performance of the reconstruction algorithms in various parameter regimes, and further validate our analysis by performing reconstructions on experimental data. Finally, we examine parameter regimes that favor specific reconstruction algorithms and provide an empirical approach for selecting regularization in Bayesian methods.
1 May 2023 in Review of Scientific Instruments
We present a technique for determining the micro-scale AC susceptibility of magnetic materials. We use the magnetic field sensing properties of nitrogen-vacancy (NV−) centers in diamond to gather quantitative data about the magnetic state of the magnetic material under investigation. A quantum diamond microscope with an integrated lock-in camera is used to perform pixel-by-pixel, lock-in detection of NV− photo-luminescence for high-speed magnetic field imaging. In addition, a secondary sensor is employed to isolate the effect of the excitation field from fields arising from magnetic structures on NV− centers. We demonstrate our experimental technique by measuring the AC susceptibility of soft permalloy micro-magnets at excitation frequencies of up to 20 Hz with a spatial resolution of 1.2 µm and a field of view of 100 µm. Our work paves the way for microscopic measurement of AC susceptibilities of magnetic materials relevant to physical, biological, and material sciences.