Yifan Mai

Yifan Mai

Auto-generated profile, based on publicly available information

Yifan Mai

Wuhan Raycus Fiber Laser Technologies Co. Wuhan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2022 in Optics Letters
Verified
Journal Article
Closed access
SGShuai Gu
Shuai Gu
XWXin Wang
Xin Wang
HJHaoqiang Jia
Haoqiang Jia
ZLZhenggang Lian
Zhenggang Lian
XSXiang Shen
Xiang Shen
SLShuqin Lou
Shuqin Lou
We report a 7-tube single-ring hollow-core anti-resonant fiber (SR-ARF) with a record low transmission loss of 4.3 dB/km @1080 nm, which is almost half of the current lowest loss record of an SR-ARF (7.7 dB/km @750 nm). The 7-tube SR-ARF has a large core diameter of 43 µm and a wide low-loss transmission window exceeding 270 nm for the 3-dB bandwidth. Moreover, it exhibits an excellent beam quality with an M2 factor of 1.05 after 10-m-long transmission. The robust single-mode operation, ultralow loss, and wide bandwidth make the fiber an ideal candidate for short-distance Yb and Nd:YAG high-power laser delivery.

2 September 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YMYifan Mai
Yifan Mai
BLBoyao Li
Boyao Li
GZGuiyao Zhou
Guiyao Zhou
MWMeng Wu
Meng Wu
Temperature monitoring plays a key role in the kinetics of chemical reaction. In this paper, a sensitive dynamic temperature monitoring sensor based on the rhodamine6G (R6g) film coated anti-resonance fiber (ARF) is proposed. Because of the high thermo-dependent fluorescence intensity of R6g, the ARF coated with R6g film is highly sensitive to the temperature variation, forming the basis of our proposed temperature sensor application. To enhance the temperature monitoring performance and strengthen the florescence intensity, one of the ARF ends spliced a silica ball for reflecting the input signal, and the other end is inserted with two tapered multimode fiber (MMF), acting as bridges for the input of pump light and the output of signal light, respectively. The dual-peak reached the temperature resolution of 3.946×10-2 °C and 3.991×10-3 °C with linearity of 0.99914 and 0.99953 respectively. The experiment results show that the output fluorescence and pump light intensity decrease with the increasing temperature. These excellent characteristics demonstrate a highly sensitive dual-peak sensor for temperature calibration with wide potential applications, such as environmental monitoring, mine monitoring and other fields of chemical kinetics.