1 October 2022 in Review of Scientific Instruments
Hard x-ray (HXR) spectroscopy is applied for diagnostics of runaway electrons in nuclear fusion reactors. The scintillation counter is one of the most commonly used types of detectors for HXR spectroscopy. It consists of a detector that emits light when excited by HXR radiation (scintillator) directly coupled to a PMT (Photomultiplier Tube) that converts light pulses into an electrical signal. This type of detector is commonly used in existing tokamaks, such as Joint European Torus (JET), Experimental Advanced Superconducting Tokamak (EAST), Compact Assembly (COMPASS), and Axially Symmetric Divertor Experiment (ASDEX-U). In all these cases, the scintillator is directly coupled to the PMT to provide the best possible light transmission efficiency. The Hard X-ray Monitor (HXRM) is one among the first plasma diagnostic systems at ITER that provides information about the energy distribution of runaway electrons inside a tokamak by HXR spectroscopy. This system also uses a scintillator and a PMT as a detector. Due to the heavy shielding of the blanket modules, vacuum vessel, and port-plugs, it is not possible to assemble the scintillator outside the tokamak vacuum vessel. The PMT detector cannot be installed in the close vicinity of the tokamak due to either the significant magnetic field or temperature. A possible solution is to decouple the scintillator from the PMT and place the PMT inside the port-cell. Light pulses will be transmitted to the PMT via a 12 m long optical fiber bundle. Evaluation of the optical transmission was carried out to assess the performance of the HXR monitor and verify possible problems related to the PMT pulse discrimination under low light conditions.
10 August 2022 in Journal of Fusion Energy
A pair of a scintillator and a Photomultiplier Tube (PMT) is often used as a Hard X-Ray (HXR) radiation detector in existing tokamaks such as JET, EAST, COMPASS or ASDEX-U. Future nuclear fusion reactors such as ITER or DEMO will use more powerful magnets and confine a larger volume of hot plasma. Placement of the detectors used for plasma diagnostic will be constrained by high temperatures, magnetic fields and ionizing radiation present near the tokamak vessel. It might be necessary to move detectors away from tokamak to a safer location. This might generate problems with pulse discrimination and transmission of the signal. In the case of the ITER tokamak, sensitive electronics such as digitizers cannot be installed close to the reactor due to harsh environmental conditions. A new approach to component placement is needed to protect those devices. The PMT signal will be transmitted via an over 100 m long coaxial cable to the digitizer located in the adjacent diagnostic building. The long cables will introduce additional signal attenuation. Also, the RF noise from the tokamak environment can couple into the signal. To improve the signal-to-noise ratio a dedicated PMT amplifier with a high output range (from + 1.5 to − 11 V) was proposed.The paper presents issues with signal transmission in HXR diagnostic systems and includes a discussion on the methodology of PMT signal transmission in the conditions of the future tokamaks. A proposal of guidelines for selection of the signal chain components and design of a dedicated PMT amplifier is part of this paper.
1 March 2026 in Review of Scientific Instruments
For the first time, the full prototype of the ITER Hard X-Ray (HXR) monitor (HXRM) system has been successfully tested in a tokamak environment during the experimental campaign in the ADITYA Upgrade tokamak located at the Institute for Plasma Research. Unlike conventional HXR diagnostic systems operating in the existing tokamaks, the ITER HXRM is uniquely designed for robustness. In the HXRM system, the UV (Ultraviolet) photons from the scintillator are guided by the optical components to the PMT (Photomultiplier Tube). This approach introduces significant optical attenuation that has a direct impact on the characteristics of the PMT signal. As a result, digital pulse processing algorithms and the I&C (Instrumentation and Control) electronics need reconsideration to work correctly. The initial validation of the HXRM system design was carried out in the laboratory at the Department of Microelectronics and Computer Science, Lodz University of Technology, where the full prototype of the ITER HXRM system was established. The laboratory test validated the design considerations and aided the development of the I&C components. However, the functionality of the system has never been tested in the tokamak environment. The HXRM prototype setup was integrated into the ADITYA Upgrade tokamak and operated during plasma discharges. The data obtained from the plasma discharge allowed verification of the I&C electronics and methodology of the signal transmission, as well as validation of the developed PMT signal simulations. Several test configurations have been tested on the ADITYA Upgrade tokamak, and the preliminary results and observations are reported herein.
25 April 2022 in Research Square
A pair of a scintillator and a Photomultiplier Tube (PMT) is often used as a Hard X-Ray (HXR) radiation detector in existing tokamaks such as JET, EAST, COMPASS or ASDEX-U. Future nuclear fusion reactors such as ITER or DEMO will use more powerful magnets and confine a larger volume of hot plasma. Placement of the detectors used for plasma diagnostic will be constrained by high temperatures, magnetic fields and ionizing radiation present near the tokamak vessel. It might be necessary to move detectors away from tokamak to a safer location. As a result, it might generate problems with pulse discrimination and transmission of the signal. In such scenario, a new approach to the design of plasma diagnostic systems such as HXR spectroscopy is required. In case of the ITER tokamak, sensitive electronics such as Field-Programmable Gate Arrays (FPGA) cannot be installed close to the reactor. The signal from the PMT will be transmitted via an over 100 m long cable to a digitizer located in the diagnostic building. Along the way, electromagnetic interferences can couple into the cable. Additional measures have to be taken to reduce the influence of noise on the signal. The paper presents issues with signal transmission in HXR diagnostic systems and includes a discussion on the methodology of PMT signal transmission in the conditions of the future tokamaks. A proposal of guidelines for selection of the signal chain components and design of a dedicated PMT amplifier is part of this paper.