25 August 2017 in Applied Optics
Inspection of defects with micrometer level on large aperture surfaces with hundreds of millimeters is one of the challenges in surface quality evaluation. Various microscopic imaging methods have been applied to inspecting the surface defects, while they are time-consuming for the small field of view and the sub-aperture stitching. To tackle this problem, a high-speed line scanning system based on the dark-field laser scattering method is proposed. The laser beam is scanned by the rotating polygon mirror to a laser line for high throughput and then the telecentric F-theta lens converges each incoming laser beam to a focused spot that creates a high intensity to enhance the signal-to-noise ratio. The scattered light from surface defect is collected by the designed integrating sphere for low background noise and the scattering signal is detected for each focused spot at a proper acquisition rate by a photomultiplier (PMT) detector with extremely short response time. In the meanwhile, the tested surface is moving perpendicular to the laser line to realize high-speed large area inspection. The defect inspection system is confirmed experimentally with laser line length of 60 mm, minimum detectable size less than 0.5 μm, and figure of merit of . The work put forward an effective method for automatic discovery of surface defects such as scratches, digs, and contaminants on large aperture surfaces.
21 January 2024 in Optics and Lasers in Engineering
17 February 2022 in Optics and Lasers in Engineering
4 April 2023 in Optics Letters
A vortex beam interferometer based on Doppler frequency shift is proposed to retrieve the dynamic non-uniform phase shift from the petal-like fringes produced by the coaxial superposition of high-order conjugated Laguerre–Gaussian modes. Unlike the uniform phase shift measurement in which the petal-like fringes rotate as a whole, the fringes due to the dynamic non-uniform phase shift rotate at different angles at different radii, resulting in highly twisted and stretched petals; this hinders rotation angle identification and phase retrieval via image morphological operation. To address the problem, a rotating chopper combined with a collecting lens and a point photodetector are placed at the exit of the vortex interferometer to introduce a carrier frequency in the absence of the phase shift. Once the phase starts to shift non-uniformly, the petals at different radii generate different Doppler frequency shifts, owing to their different rotation velocities. Thus, identification of spectral peaks near the carrier frequency immediately indicates the rotation velocities of the petals and the phase shifts at those radii. The results verified a relative error of phase shift measurement to be within 2.2% at the surface deformation velocities of 1, 0.5, and 0.2 µm/s. The method manifests itself to have potential in exploiting mechanical and thermophysical dynamics from the nanometer to micrometer scale.
26 April 2018 in Optics Express
The simultaneous determination of t, n(λ), and κ(λ) of thin films can be a tough task for the high correlation of fit parameters. The strong assumptions about the type of dispersion relation are commonly used as a consequence to alleviate correlation concerns by reducing the free parameters before the nonlinear regression analysis. Here we present an angle-resolved spectral reflectometry for the simultaneous determination of weakly absorbing thin film parameters, where a reflectance interferogram is recorded in both angular and spectral domains in a single-shot measurement for the point of the sample being illuminated. The variations of the phase recovered from the interferogram as functions of t, n, and κ reveals that the unwrapped phase is monotonically related to t, n, and κ, thereby allowing the problem of correlation to be alleviated by multiple linear regression. After removing the 2π ambiguity of the unwrapped phase, the merit function based on the absolute unwrapped phase performs a 3D data cube with variables of t, n and κ at each wavelength. The unique solution of t, n, and κ can then be directly determined from the extremum of the 3D data cube at each wavelength with no need of dispersion relation. A sample of GaN thin film grown on a polished sapphire substrate is tested. The experimental data of t and [n(λ), κ(λ)] are confirmed by the scanning electron microscopy and the comparison with the results of other related works, respectively. The consistency of the results shows the proposed method provides a useful tool for the determination of the thickness and optical constants of weakly absorbing thin films.
22 May 2023 in Optics Letters
An interferogram demodulation method based on azimuthal complex spectrum analysis is proposed for achieving picometer-scale accuracy with an optical vortex interferometer (OVI). The OVI uses conjugated p-radial-order Laguerre–Gaussian beams to produce a high-order petal-like interferogram. A camera with a multi-ring pattern written on its sensor is used to convert the interferogram into multiple azimuthal intensity profiles. A phase shift subjected to either uniform surface displacement or axisymmetric non-uniform surface deformation can be retrieved from the complex spectra of the azimuthal intensity profiles at the main frequency components. The experiment verified that the measurement error is 84 pm for a displacement of 10 nm and 0.359 nm for a deformation magnitude of 100 nm. The effect of surface misalignment on the measurement result is also discussed. The proposed method provides an effective and highly accurate method of interferogram demodulation for the OVI and extends the applicability of OVI from uniform surface displacement measurement to axisymmetric non-uniform surface deformation measurement.