Yunyun Chen

Yunyun Chen

Auto-generated profile, based on publicly available information

Yunyun Chen

Eye Hospital and School of Ophthalmology and Optometry Wenzhou Medical University Wenzhou China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2022 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
XLXUE LI
XUE LI
YHYingying Huang
Yingying Huang
JZJiali Zhang
Jiali Zhang
CDChenglu Ding
Chenglu Ding
YCYunyun Chen
Yunyun Chen
JBJinhua Bao
Jinhua Bao
Purpose: To investigate whether the treatment zone (TZ) decentration in orthokeratology (OK) lenses affects retinal expansion in Chinese children with myopia. Methods: Children aged 8 to 13 years ( n = 30) were assessed over 13 months comprising 12 months of OK lens wear followed by discontinuation of lens wear for 1 month. Corneal topography was measured at 0, 1, 3, 6, 9, 12 and 13 months. TZ decentration of the OK lens was calculated, and subjects were subdivided into a small decentration group (group S) and a large decentration group (group L) based on the median value of the weighted average decentration (d ave ). Central axial length (AL) and peripheral eye lengths (PELs) at the central retina, as well as 10°, 20° and 30° nasally and temporally were measured at 0 and 13 months under cycloplegia. Second‐order polynomial ( y = ax 2 + bx + c) and linear fits ( y = Kx + B) were applied to the peripheral relative eye length (PREL), and the coefficients ‘a’ and ‘K’ were used to describe the shape of the eye. Results: Mean AL growth for one year was 0.28 ± 0.17 mm. In a multiple linear regression model, AL elongation was related to the baseline age ( β = −0.41, p = 0.01) and the d ave ( β = −0.37, p = 0.03) ( R 2 = 0.34, p = 0.002). When compared with smaller d ave (0.45 ± 0.15 mm), a larger d ave (0.89 ± 0.17 mm) was associated with slower ocular growth (central: 0.20 ± 0.13 mm vs. 0.35 ± 0.17 mm, p = 0.009; 10° nasal: 0.26 ± 0.18 mm vs. 0.45 ± 0.21 mm, p = 0.02; 10° temporal: 0.17 ± 0.14 mm vs. 0.32 ± 0.19 mm, p = 0.02) and more oblate retina shape (‘a’: −0.13 ± 0.02 vs. −0.14 ± 0.02, p = 0.02; K nasal : 0.35 ± 0.11 vs. 0.39 ± 0.09, p = 0.02; K temporal : −0.42 ± 0.08 vs. −0.46 ± 0.08, p = 0.004). Conclusions: Greater TZ decentration with the use of OK lenses was associated with slower axial growth and a more oblate retinal shape. TZ decentration caused local defocusing changes, which may inhibit myopic progression. These findings may have important implications for improving optical designs for myopia control.

5 December 2021 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
PDF file
CDChenglu Ding
Chenglu Ding
YCYunyun Chen
Yunyun Chen
XLXue Li
Xue Li
YHYingying Huang
Yingying Huang
HCHao Chen
Hao Chen
JBJinhua Bao
Jinhua Bao
Purpose: This study aimed to investigate the effect of orthokeratology (OK) on accommodative function and aberrations, to explore the correlations between them and determine what role they play in myopia control. Methods: In this prospective case‐controlled study, 61 children were divided into an OK ( n = 30) and a single‐vision spectacles (SVS) ( n = 31) group. Accommodation and ocular wavefront aberrations in the OK group were measured at baseline and after 1, 3, 6, 9 and 12 months of OK wear, and again at 1 month after stopping OK (13 th month). The same procedure was performed in the SVS group at baseline and at 3, 6 and 12 months. Axial length (AL), accommodative lag area and aberrations including spherical aberration (SA), coma and total higher‐order aberrations (HOAs) were analysed. Results: During OK wear, the accommodative lag area at each visit was lower than the baseline level (all p < 0.01); all aberrations at each visit were higher than pre‐treatment (all p < 0.001). After 1 month of OK treatment, changes in accommodative lag area and SA did not show significant correlation ( p = 0.16), but after OK cessation these changes were correlated ( p = 0.01). In the OK group, multivariate regression analysis showed changes in accommodative lag area were associated with AL progression in the first 6 months but not in the 1‐year analysis. For the SVS group, there were no significant changes in the accommodative lag area or any aberrations during the study period. Conclusions: Increased HOAs and improved accommodative accuracy were observed during OK treatment, but began to regress after the cessation of OK. A significant positive correlation between improved accommodative accuracy and slowed axial elongation was only observed during the first 6 months of treatment.

19 June 2021 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Open access
PDF file
AMAnastasios Maniakas
Anastasios Maniakas
YHYing C Henderson
Ying C Henderson
HHHu Hei
Hu Hei
SPShaohua Peng
Shaohua Peng
YCYunyun Chen
Yunyun Chen
SLStephen Y Lai
Stephen Y Lai
Context Anaplastic thyroid cancer (ATC) is a rare, aggressive, and deadly disease. Robust preclinical thyroid cancer models are needed to adequately develop and study novel therapeutic agents. Patient-derived xenograft (PDX) models may resemble patient tumors by recapitulating key genetic alterations and gene expression patterns, making them excellent preclinical models for drug response evaluation. Objective We developed distinct ATC PDX models concurrently with cell lines and characterized them in vitro and in vivo. Methods Fresh thyroid tumor from patients with a preoperative diagnosis of ATC was surgically collected and divided for concurrent cell line and PDX model development. Cell lines were created by generating single cells through enzymatic digestion. PDX models were developed following direct subcutaneous implantation of fresh tumor on the flank of immune compromised/athymic mice. Results Six ATC PDX models and 4 cell lines were developed with distinct genetic profiles. Mutational characterization showed one BRAF/TP53/CDKN2A, one BRAF/CDKN2A, one BRAF/TP53, one TP53 only, one TERT-promoter/HRAS, and one TERT-promoter/KRAS/TP53/NF2/NFE2L2 mutated phenotype. Hematoxylin-eosin staining comparing the PDX models to the original patient surgical specimens show remarkable resemblance, while immunohistochemistry stains for important biomarkers were in full concordance (cytokeratin, TTF-1, PAX8, BRAF). Short tandem repeats DNA fingerprinting analysis of all PDX models and cell lines showed strong concordance with the original tumor. PDX successful establishment rate was 32%. Conclusion We have developed and characterized 6 novel ATC PDX models with 4 matching cell lines. Each PDX model harbors a distinct genetic profile, making them excellent tools for preclinical therapeutic trials.

28 August 2024 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
SWShuai Wang
Shuai Wang
BZBeilei Zhang
Beilei Zhang
QLQiming Liu
Qiming Liu
FZFan Zhou
Fan Zhou
YCYunyun Chen
Yunyun Chen
JXJingjing Xu
Jingjing Xu

11 April 2023 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
YCYunyun Chen
Yunyun Chen
CDChenglu Ding
Chenglu Ding
XLXUE LI
XUE LI
YHYingying Huang
Yingying Huang
FZFengchao Zhou
Fengchao Zhou
JBJinhua Bao
Jinhua Bao
Purpose: The aim of this study was to evaluate the short‐term effects of peripheral gradient high‐addition multifocal soft contact lenses (MFSCLs) and orthokeratology (Ortho‐K lenses) on visual performance in myopic children. Methods: Thirty myopic children participated in this prospective study. Each participant wore different sets of lenses in the following sequence: single‐vision spectacles (SVSPs) as a control, MFSCLs and Ortho‐K lenses. Ocular aberrations, topography, high‐contrast visual acuity (HCVA), low‐contrast visual acuity (LCVA) and accommodation of the right eye were measured with each type of correction on a different day. Results: Compared with SVSPs, high‐addition MFSCLs and Ortho‐K lenses significantly increased all items of aberrations (all p < 0.05) except trefoil ( p = 0.17). MFSCLs induced less coma, root mean square of the third‐order aberration (RMS3) and higher order aberrations than Ortho‐K lenses (all p < 0.05). No significant difference in HCVA was found across the three correction types ( F = 1.19, p = 0.39). In terms of LCVA, MFSCLs performed significantly poorer than SVSPs (difference, 0.16 logMAR; p = 0.001) and slightly worse than Ortho‐K lenses (difference, 0.08 logMAR; p = 0.35). No significant difference in decentration was found between the two types of contact lenses, and no associations were observed between decentration and visual acuity at both high‐ and low‐contrast levels (all p > 0.05). For MFSCLs, decentration was positively related to coma ( r = 0.43, p = 0.02) and RMS3 ( r = 0.44, p = 0.02), which was not the case for Ortho‐K lenses. Accommodative facility was worse with MFSCLs than Ortho‐K lenses ( p = 0.001). Conclusion: Multifocal soft contact lenses differed from Ortho‐K lenses in aberration profile and LCVA, although decentration was similar. Decentration <1 mm had minimal influence on both HCVA and LCVA for either type of correction, but significantly increased third‐order aberrations for MFSCLs, but not Ortho‐K lenses.