Vitria Wuri Handayani

Vitria Wuri Handayani

Auto-generated profile, based on publicly available information

Vitria Wuri Handayani

Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2024 in Acta Odontologica Scandinavica
Verified
Journal Article
Open access
PDF file
VHVitria Wuri Handayani
Vitria Wuri Handayani
AYAhmad Yudianto
Ahmad Yudianto
MMMieke Sylvia M.A.R
Mieke Sylvia M.A.R
RRRiries Rulaningtyas
Riries Rulaningtyas
MCMuhammad Rasyad Caesarardhi
Muhammad Rasyad Caesarardhi
Background: The use of cephalometric pictures in dental radiology is widely acknowledged as a dependable technique for determining the gender of an individual. The Visual Geometry Group 16 (VGG16) and Visual Geometry Group 19 (VGG19) algorithms have been proven to be effective in image classification. Objectives: To acknowledge the importance of comprehending the complex procedures associated with the generation and adjustment of inputs in order to obtain precise outcomes using the VGG16 and VGG19 algorithms. Material and Method: The current work utilised a dataset including 274 cephalometric radiographic pictures of adult Indonesians’ oral health records to construct a gender classification model using the VGG16 and VGG19 architectures using Python. Result: The VGG16 model has a gender identification accuracy of 93% for females and 73% for males, resulting in an average accuracy of 89% across both genders. In the context of gender identification, the VGG19 model has been found to achieve an accuracy of 0.95% for females and 0.80% for men, resulting in an overall accuracy of 0.93% when considering both genders. Conclusion: The application of VGG16 and VGG19 models has played a significant role in identifying gender based on the study of cephalometric radiography. This application has demonstrated the exceptional effectiveness of both models in accurately predicting the gender of Indonesian adults.

25 August 2025 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
VHVitria Wuri Handayani
Vitria Wuri Handayani
MRMieke Sylvia Margareth Amiatun Ruth
Mieke Sylvia Margareth Amiatun Ruth
RRRiries Rulaningtyas
Riries Rulaningtyas
MCMuhammad Rasyad Caesarardhi
Muhammad Rasyad Caesarardhi
BYBayu Azra Yudhantorro
Bayu Azra Yudhantorro
AYAhmad Yudianto
Ahmad Yudianto
Accurately determining sex using features like facial bone profiles and teeth is crucial for identifying unknown victims. Lateral cephalometric radiographs effectively depict the lateral cranial structure, aiding the development of computational identification models. This study develops and evaluates a sex prediction model using cephalometric radiographs with several convolutional neural network (CNN) architectures. The primary goal is to evaluate the model’s performance on standardized radiographic data and real-world cranial photographs to simulate forensic applications. Six CNN architectures—VGG16, VGG19, MobileNetV2, ResNet50V2, InceptionV3, and InceptionResNetV2—were employed to train and validate 340 cephalometric images of Indonesian individuals aged 18 to 40 years. The data were divided into training (70%), validation (15%), and testing (15%) subsets. Data augmentation was implemented to mitigate class imbalance. Additionally, a set of 40 cranial images from anatomical specimens was employed to evaluate the model’s generalizability. Model performance metrics included accuracy, precision, recall, and F1-score. CNN models were trained and evaluated on 340 cephalometric images (255 females and 85 males). VGG19 and ResNet50V2 achieved high F1-scores of 95% (females) and 83% (males), respectively, using cephalometric data, highlighting their strong class-specific performance. Although the overall accuracy exceeded 90%, the F1-score better reflected model performance in this imbalanced dataset. In contrast, performance notably decreased with cranial photographs, particularly when classifying female samples. That is, while InceptionResNetV2 achieved the highest F1-score for cranial photographs (62%), misclassification of females remained significant. Confusion matrices and per-class metrics further revealed persistent issues related to data imbalance and generalization across imaging modalities. Basic CNN models perform well on standardized cephalometric images but less effectively on photographic cranial images, indicating a domain shift between image types that limits generalizability. Improving real-world forensic performance will require further optimization and more diverse training data. Not applicable.

31 July 2024 in Russian Journal of Forensic Medicine
Verified
Journal Article
Closed access
PDF file
VHVitria Wuri Handayani
Vitria Wuri Handayani
AYAhmad Yudianto
Ahmad Yudianto
MSMar Mieke Sylvia
Mar Mieke Sylvia
RRRiries Rulaningtyas
Riries Rulaningtyas
MCMuhammad Rasyad Caesarardhi
Muhammad Rasyad Caesarardhi
RPRamadhan Hardani Putra
Ramadhan Hardani Putra
BACKGROUND: When creating models utilizing artificial neural networks, the quantity of training data and the distribution of data need to be considered, particularly when making gender predictions. AIM: This study seeks to determine the potential impact of using the synthetic minority oversampling technique (SMOTE) on gender prediction using the artificial neural networks model. MATERIALS AND METHODS: The current study utilized a dataset consisting of 297 cephalometric measurements from Indonesian patients, comprising 229 samples from females and 68 samples from males. WebCeph is used to measure certain parameters, such as Sella-Nation-Point A (SNA) angle, mandibular length, mandibular angle, Sella-Glabella-Point A (SGA) angle, and diagnosis. Data processing and artificial neural networks model creation were conducted using Python. RESULTS: The gender identification accuracy of the artificial neural networks model is 87% for females and 0% for males, resulting in an overall average accuracy of 78%. When using SMOTE, the accuracy is 22%, with 0% for females and 37% for males. However, when using SMOTE and normalization, the accuracy increases to 71%, with 82% for females and 30% for males. The accuracy of normalization without SMOTE is 76%, with 86% for females and 14% for males. CONCLUSIONS: This research has proven the efficacy of SMOTE in improving the classification of male matrices. Nevertheless, this study reveals that the overall accuracy results of SMOTE are suboptimal in comparison to the absence of SMOTE and normalization. The application of data balancing strategies is necessary to achieve optimal accuracy in gender prediction when artificial neural networks, and other parameters must be applied.

18 March 2026 in JMIR AI
Verified
Journal Article
Open access
VHVitria Wuri Handayani
Vitria Wuri Handayani
MRMieke Sylvia Margaretha Amiatun Ruth
Mieke Sylvia Margaretha Amiatun Ruth
RRRiries Rulaningtyas
Riries Rulaningtyas
AKArofi Kurniawan
Arofi Kurniawan
BYBayu Azra Yudhantorro
Bayu Azra Yudhantorro
AYAhmad Yudianto
Ahmad Yudianto
Background: Mandibular structures offer resilient features for forensic identification where partial remains are available in postmortem condition. Deep learning applied to cephalometric radiographs offers an opportunity to predict demographic attributes, such as age and sex, which are critical in forensic and clinical contexts. Objective: This study aimed to develop and evaluate a multitask deep learning framework for age estimation and sex prediction from cropped mandibular regions of cephalometric radiographs, comparing multiple convolutional neural network backbones and preprocessing scenarios to address class imbalance. Methods: A total of 340 anonymized cephalometric radiographs from Indonesian individuals aged 8 to 40 years were collected and manually cropped into 2 mandibular regions of interest: mandibular length and mandibular angle, producing 680 validated samples. Images were resized to 224×224 pixels and processed under 4 preprocessing scenarios: original, Synthetic Minority Oversampling Technique, StandardScaler, and Synthetic Minority Oversampling Technique+StandardScaler. Six pretrained convolutional neural network backbones (MobileNetV2, ResNet50V2, InceptionV3, InceptionResNetV2, VGG16, and VGG19) were fine-tuned within a multitask framework. Performance was evaluated using mean absolute error and mean absolute percentage error for age estimation and accuracy and F 1 -score for sex prediction. Results: VGG16 achieved the best performance for age estimation, with the lowest mean absolute error of 3.19 years and mean absolute percentage error of 13.19% in the original dataset. For sex prediction, VGG16 achieved the highest accuracy (86%) and balanced F 1 -scores (female: 92%; male: 63%) under the StandardScaler condition, followed by VGG19 (accuracy=82%). Conclusions: Combining mandibular cropping with deep learning and balanced preprocessing scenarios enhances demographic prediction in cephalometric radiographs. The findings emphasize the potential use of artificial intelligence–assisted forensic odontology to support disaster victim identification when partial remains are available.


22 November 2024 in Journal Of Vocational Health Studies
Verified
Journal Article
Open access
PDF file
MAMarvita
Marvita
NWNoeroel Widajati
Noeroel Widajati
SRShafira Nurul Ramadhani
Shafira Nurul Ramadhani
VHVitria Wuri Handayani
Vitria Wuri Handayani
Background: Computer Vision Syndrome (CVS) symptoms can result from improper computer use. The manifestation of symptoms may encompass ocular strain, cephalalgia, ocular pain, xerophthalmia, diplopia, and visual blurring, influencing occupational efficiency. Purpose: To analyze factors related to CVS complaints among programmers at an IT consulting company in Jakarta. Method: A cross-sectional quantitative descriptive research involving 60 participants was conducted. The research examined the relationship between CVS complaints among programmers and several independent variables, including individual characteristics such as gender, age, visual aids, rest time, duration of computer use, work period, and workstation factors such as viewing distance from the screen to the horizontal eye line. The Spearman rank correlation test was utilized for data analysis. Result: Specifically, gender (sig.= 0.000), visual aids (sig.= 0.003), and the position of the top screen with the horizontal line of the eye (sig.= 0.029) were significantly related to CVS complaints. Age (sig.= 0.608), length of rest (sig.=0.055), duration of computer use (sig.= 0.138), work period (sig.= 0.717), and screen viewing distance (sig.= 0.058) did not show a significant relationship with CVS complaints. Conclusion: There is a relationship between gender, visual aids, and the position of the top of the screen with the horizontal line of the eye with CVS complaints. There is no relationship between age, length of rest, duration of computer use, working time, and screen viewing distance. Companies are expected to provide education regarding the correct use of computers, regular eye health checks, and enforce a 20-20-20 rule (20 minutes of rest, looking at objects 20 feet away for 20 seconds).