27 February 2014 in Advanced Materials Research
The increase in energy prices resulted in the formation of new houses in the low-energy and passive standard. In particular, the development of wooden buildings in recent years has experienced a boom. More and more, their positive qualities come to the attention of potential investors. Thanks to this the new technologies of construction are still developed and the new wood-based materials tested. The continuous improvement of the thermal insulating materials and as well as technical equipment of buildings such as ventilation, heat recovery, solar and photovoltaic systems is recorded. All of these materials and technologies must follow the standards which tightened the thermal technical requirements. This led to the sophisticated compositions of individual structures and the use of better materials. Not always declared properties of the materials or construction planners are designed in accordance with the calculated values. In practice there is often ill-composition design of the construction or improper assembling of wooden parts which may result in an increase in thermal loss of the building, disturbed microclimate inside the building, but also negatively affecting the lives of individual structural units which implies that we should deal with these problems significantly.
27 February 2014 in Advanced Materials Research
The use of building information modeling (BIM) in the Czech Republic is currently at the stage of being slowly established in the Czech building environment. From the viewpoint of applicability in the building industry, the issues of BIM in the Czech Republic are very desirable, mainly because of ever-increasing pressure on the sustainability of construction. This approach is gradually used by some, often multinational, construction companies. The article focuses on finding the possible optimization of approach to the planning and operation of buildings in terms of the energy sustainability of buildings.
13 December 2013 in Applied Mechanics and Materials
Permanent increase of energy prices leads to the construction of new houses in the low-energy and passive standard. In particular, the development of wooden buildings in recent years has experienced a boom and their positive qualities are coming to the attention of potential investors. Thanks to this the new technologies of construction are still being developed and the new wood-based materials tested. All of these materials and technologies must follow the standards which tightened the thermal technical requirements.
1 January 2013 in Advanced Materials Research
The value of air permeability, or the value of n50 provides important information about the impermeability of the building envelope and thus the quality of internal environment of the building. It is also one of the main evaluation criteria in classifying energy efficient buildings. Air permeability is determined by Blower Door Test where the fan blows air in or out from the measured area. The measurement is performed in a overpressure and afterwards in a underpressure during which the leaks are detected. The frame is usually placed into the front door which themselves is a weak part in the building envelope, and thus the rate of leakage completely denies. The effect of leakage of the front door is so significant that it can often cause a misclassification of the energy efficient buildings. We have tested this hypothesis by Blower Door Test on a passive timber construction build in 2007 during which we have measured the object in position of measuring device placed in the front door and the balcony door that are not encumbered by leaks caused by a security hardware and by other specific elements
27 February 2014 in Advanced Materials Research
Carbon dioxide is the most common air pollutant in residential buildings. The source of this gas is primarily a human ́s metabolism, respiratory and thermoregulatory processes. With increasing concentration of carbon dioxide the amount of water vapor increases in the atmosphere and thus the relative humidity. Living without air conditioning is today unthinkable in large buildings and in buildings where we can expect too many people. There is no so high emphasis on environmental parameters in family housing such as in community facilities. The authors in this paper are trying to compare the conditions in a common family house and compare it to the standard of modern living - an experimental passive house in the area of FAST, where is partially controlled internal environment already and meets the requirements for healthy living.
19 February 2018 in IOP Conference Series: Materials Science and Engineering
This paper is focused on influence of an additional concrete wall on indoor temperature in the light modular construction. Typically, there are no accumulation materials used in these constructions. The study was based on measurements obtained from a full-scale experimental set-up built for this purpose. Two identical modular constructions were used; one of them was equipped with an additional concrete wall. Indoor temperatures were measured in the course of time and compared.