Hui Hui Chai

Hui Hui Chai

Auto-generated profile, based on publicly available information

Hui Hui Chai

Institute of Oceanographic Instrumentation, Qilu University of Technology (Shandong Academy of Sciences), Qingdao 266061, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
HCHui Hui Chai
Hui Hui Chai
FCFeng Chen
Feng Chen
SZShu Jie Zhang
Shu Jie Zhang
YLYa Dan Li
Ya Dan Li
Zhisong LuZhisong Lu
Zhisong Lu
LYLing Yu
Ling Yu
The root system of plants is a major component of their bodies in terms of both function and bulk. The investigation of root system development is greatly assisted by microfluidic devices, which improve the spatial and temporal resolution of observations without destroying tissue. In the present study, a multi-chamber petaloid root-growth chip was developed for studying the development and physiology of root systems that have thin branching structures (i.e., fibrous root systems). The petaloid root-growth chip includes a central seed germination chamber and five root-growth chambers for observing the development of fibrous roots. The proposed device was applied for investigating the root system development of Oryza sativa. The phenotype and growth kinetics of O. sativa root systems grown in the proposed device were compared with those obtained during growth in a conventional conical flask with agar-based medium, and the results indicated that cultivation in the miniaturized device did not delay root system growth in the early stage (≤2 weeks). In addition, the transparent device enabled the non-destructive observation of the developmental and microstructural characteristics of the roots, such as the root caps, root border cells, and root hairs. Moreover, the ability to control the microenvironment in each of the five root-growth chambers individually facilitated the investigation of specific adaptations in the fibrous root growth of single O. sativa seedlings to different drought stresses. Accordingly, five polyethylene glycol (PEG)6000-induced drought stress conditions were established in the five root-growth chambers to investigate the root development of a single O. sativa seedling in the central germination chamber. In situ observations demonstrated that the different PEG6000-induced conditions affected the root growth responses and root microstructural adaptations of the single seedlings in each root-growth chamber. Therefore, the petaloid root-growth microfluidic chip can eliminate the effects of variations in different plant seeds to reveal the responses of plants to different environmental conditions more objectively while concurrently allowing for non-destructive observations at very high spatial and temporal resolution.

1 January 2021 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
HCHui Chai
Hui Chai
SLShixuan Liu
Shixuan Liu
XYXianglong Yang
Xianglong Yang
XWXiaozheng Wan
Xiaozheng Wan
SCshizhe Chen
shizhe Chen
QZQiang Zhao
Qiang Zhao
At present, the methods and instruments for measuring the precipitation on land may not effectively work in the offshore corrosion environment which is characterized by salt and humid. The research look at investigating the reliable and precision approach of measuring rainfall and a capacitive rain gauge for the marine environment is developed. Firstly, according to the working principle and performance requirements of the capacitive rain gauge, the modular mechanical structure and capacitance voltage conversion circuit of the rain gauge are designed, and the calibration and stability experiments of the prototype are tested to evaluate the measurement error and exam the accuracy of the rain gauge measurement results changing over time. Then, environmental adaptability experiment is carried out on the capacitive rain gauge to explore its performance in the environment of temperature and humidity changes as well as salt spray. Finally, the feasibility of the rain gauge used in the marine environment is verified by the sea test of the prototype. The measurement error of the developed capacitive rain gauge is less than 1 mm, which provides a realization method for the measurement of precipitation in the marine environment.