For the purpose of realizing the dynamic angle measurement and calibration of the inertial equipment (such as rotary table), a dynamic angle measurement system based on the autocollimator and the fiber optic gyroscope (FOG), which can be used as an angle standard device, is designed in this paper. In this system, the scale factor of the FOG can be calibrated in the field application based on the autocollimator with the precision of 1 '' in the range of ±0.05°. Furthermore, the angle measurement deviation between the FOG and the rotary table can be limited in ±3 '' when the scale factor of the FOG is calibrated by the autocollimator when necessary. This research can guarantee the long-term accuracy of the scale factor of the FOG in the field application and it will greatly promote the applications of the FOG as an angle standard device in the field of dynamic angle measurement.
The focusing properties of elegant third-order Hermite–Gaussian beams (TH3GBs) and the radiation forces exerted on dielectric spherical particles produced by such beams in the Rayleigh scattering regime have been theoretically studied. Numerical results indicate that the elegant TH3GBs can be used to simultaneously trap and manipulate nanosized dielectric spheres with refractive indexes lower than the surrounding medium at the focus and those with refractive indexes larger than the surrounding medium in the focal vicinity. Furthermore, by changing the radius of the beam waist, the transverse trapping range and stiffness at the focal plane can be changed.
14 May 2021 in IEEE Transactions on Instrumentation and Measurement
Research on the transfer and traceability of a dynamic angle has great value in the field of measurement. The fiber optic gyroscope (FOG), as a high-precision angular velocity sensor, has broad prospects in this application. The focus of this article is the evaluation of angle measurement uncertainty of the FOG based on the Monte Carlo method (MCM). The angle measurement uncertainty evaluation model is established based on the principle of the FOG, and the simulation is carried out in detail based on the model and MCM. Finally, the angle measurement experiments of the FOG are carried out in the National Institute of Metrology, China. The experimental results show that the angle measurement uncertainty within the range of 360° is about 0.96 '' in a relatively stable environment when the confidence probability is 95%. It is highly consistent with the simulation, which confirms the accuracy of the evaluation model and the effectiveness of MCM.
Interferometric fiber-optic gyroscopes (IFOGs) are widely utilized due to their compact size and solid-state design. However, their sensitivity of detecting rotation is limited by the relative intensity noise (RIN) associated with the broadband source. To overcome this limitation, a conventional fiber ring resonator (FRR) can be employed to filter the RIN specifically at the IFOG frequency. Nonetheless, implementing this solution necessitates a fiber delay line with a length equal to that of the fiber coil. To address this challenge, we propose the utilization of passive and active dual FRRs and examine their RIN suppression characteristics. By utilizing the active dual FRR as an optimized gain point filter, we achieve a theoretical RIN suppression ratio equivalent to that of the traditional FRR, while significantly reducing the required length of the fiber delay line.
This paper presents a phase unwrapping method of heterodyne three frequency non-equal step phase shift, to surmount disadvantages of needing dozens of images in 3-D measurement techniques of multi-frequency phase shift. The method selects three frequencies. Firstly, four-step phase-shifting algorithm is used to calculate wrapped phase and average intensity of the intermediate frequency. Then the wrapped phases of other frequencies are obtained utilizing two-step phase-shifting algorithm. Finally, the absolute phase is calculated using heterodyne method. In addition, the contour sine/cosine filter method is utilized to filter noise by the fringe orientation information. The 3-D points cloud of standard planar and calibration target are reconstructed experimentally. Then the planeness of standard planar is calculated. The centers of markers of calibration target are extracted to calculate distance between two adjacent circles. Experiments demonstrate that the proposed method reduces the number of fringe images, eliminates the effects of noise efficaciously.
In this paper, we investigate the mean curvature flow of compact surfaces in $4$-dimensional space forms. We prove the convergence theorems for the mean curvature flow under certain pinching conditions involving the normal curvature, which generalise Baker-Nguyen's convergence theorem.