Kang Li

Kang Li

Auto-generated profile, based on publicly available information

Kang Li

School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Energy Reports
Verified
Journal Article
Open access
YFYidong Fang
Yidong Fang
FYFei Ye
Fei Ye
YZYue Zhu
Yue Zhu
KLKang Li
Kang Li
JSJiali Shen
Jiali Shen
LSLin Su
Lin Su

17 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
YCYongbao Chen
Yongbao Chen
Zhe ChenZhe Chen
Zhe Chen
Xiaolei YuanXiaolei Yuan
Xiaolei Yuan
LSLin Su
Lin Su
KLKang Li
Kang Li
The penetration rates of intermittent renewable energies such as wind and solar energy have been increasing in power grids, often leading to a massive peak-to-valley difference in the net load demand, known as a “duck curve”. The power demand and supply should remain balanced in real-time, however, traditional power plants generally cannot output a large range of variable loads to balance the demand and supply, resulting in the overgeneration of solar and wind energy in the grid. Meanwhile, the power generation hours of the plant are forced to be curtailed, leading to a decrease in energy efficiency. Building demand response (DR) is considered as a promising technology for the collaborative control of energy supply and demand. Conventionally, building control approaches usually consider the minimization of total energy consumption as the optimization objective function; relatively few control methods have considered the balance of energy supply and demand under high renewable energy penetration. Thus, this paper proposes an innovative DR control approach that considers the energy flexibility of buildings. First, based on an energy flexibility quantification framework, the energy flexibility capacity of a typical office building is quantified; second, according to energy flexibility and a predictive net load demand curve of the grid, two DR control strategies are designed: rule-based and prediction-based DR control strategies. These two proposed control strategies are validated based on scenarios of heating, ventilation, and air conditioning (HVAC) systems with and without an energy storage tank. The results show that 24–55% of the building’s total load can be shifted from the peak load time to the valley load time, and that the duration is over 2 h, owing to the utilization of energy flexibility and the implementation of the proposed DR controls. The findings of this work are beneficial for smoothing the net load demand curve of a grid and improving the ability of a grid to adopt renewable energies.

22 August 2020 in Journal of Thermal Science
Verified
Journal Article
Closed access
PDF file
YFYidong Fang
Yidong Fang
JSJiali Shen
Jiali Shen
YZYue Zhu
Yue Zhu
FYFei Ye
Fei Ye
KLKang Li
Kang Li
LSLin Su
Lin Su

15 February 2019 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
THTianen Hu
Tianen Hu
Yidong FangYidong Fang
Yidong Fang
LSLin Su
Lin Su
KLKang Li
Kang Li

1 July 2019 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
KLKang Li
Kang Li
XZXuejin Zhou
Xuejin Zhou
RTRan Tu
Ran Tu
HTHe Tu
He Tu
YFYidong Fang
Yidong Fang
LSLin Su
Lin Su

8 January 2019 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
THTianen Hu
Tianen Hu
KLKang Li
Kang Li
YFYidong Fang
Yidong Fang
LSLin Su
Lin Su
ZSZhaopu Song
Zhaopu Song
LSLei Sheng
Lei Sheng