Cinzia Cianfrocca

Cinzia Cianfrocca

Auto-generated profile, based on publicly available information

Cinzia Cianfrocca

Department of Cardiology, San Filippo Neri Hospital, Rome, Italy

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in International Journal of Cardiology
Verified
Journal Article
Closed access
CCCinzia Cianfrocca
Cinzia Cianfrocca
MLMaria Luisa Loricchio
Maria Luisa Loricchio
FPFrancesco Pelliccia
Francesco Pelliccia
VPVincenzo Pasceri
Vincenzo Pasceri
AAAntonio Auriti
Antonio Auriti
MSMassimo Santini
Massimo Santini

30 September 2008 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
PDF file
CCCinzia Cianfrocca
Cinzia Cianfrocca
Francesco PellicciaFrancesco Pelliccia
Francesco Pelliccia
VPVincenzo Pasceri
Vincenzo Pasceri
AAAntonio Auriti
Antonio Auriti
VGVincenzo Guido
Vincenzo Guido
MSMassimo Santini
Massimo Santini

16 June 2007 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
AAAntonio Auriti
Antonio Auriti
CPChristian Pristipino
Christian Pristipino
CCCinzia Cianfrocca
Cinzia Cianfrocca
AGAntonino Granatelli
Antonino Granatelli
VGVincenzo Guido
Vincenzo Guido
MSMassimo Santini
Massimo Santini
Coronary flow reserve (CFR) recording by means of transthoracic echocardiography (TTDE) in all the main distal coronary arteries is a challenge for advanced echocardiography. Validation studies of TTDE versus Doppler-wire (DW) recordings are available for Left Anterior Descending artery (LAD) and the Posterior Descending coronary artery (PD), but lacking for the more technically challenging Left Circumflex coronary artery (LCx).

1 November 2002
Verified
Journal Article
Closed access
CCCinzia Cianfrocca
Cinzia Cianfrocca
Francesco PellicciaFrancesco Pelliccia
Francesco Pelliccia
AAAntonio Auriti
Antonio Auriti
MSMassimo Santini
Massimo Santini

27 January 2009 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
Francesco PellicciaFrancesco Pelliccia
Francesco Pelliccia
CCCinzia Cianfrocca
Cinzia Cianfrocca
VPVincenzo Pasceri
Vincenzo Pasceri
AGAntonino Granatelli
Antonino Granatelli
GSGiulio Speciale
Giulio Speciale
CPChristian Pristipino
Christian Pristipino
Aims Thrombus formation leading to ischaemic stroke is a major concern after transcathether occlusion of interatrial communications. The aim of our study was to verify if postprocedural transoesophageal echocardiography (TEE) might improve timely detection and management of thrombus formation. Methods and results We studied 65 patients with patent foramen ovale or atrial septal defect who received an atrial septal closure device. Transoesophageal echocardiography was used to guide the procedure, and was repeated <1 h after the end of the procedure, at 30 day and 6 month follow-up visits. Transoesophageal echocardiography <1 h after procedure revealed a left-sided thrombus attached to the device in three patients. All cases were successfully treated by thrombolytic therapy with full-dose tenecteplase (0.53 mg/kg in 5–10 s) with disappearance of thrombus in 15–60 min. No cerebrovascular event was recorded during a follow-up of 311 ± 235 days. Conclusion Thrombus formation on interatrial closure devices can occur soon after device implantation and can be timely detected by postprocedural TEE.

17 August 2010 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
AAAntonio Auriti
Antonio Auriti
VLVincenzo Loiaconi
Vincenzo Loiaconi
CPChristian Pristipino
Christian Pristipino
FCFrancesco Saverio Leonardi Cattolica
Francesco Saverio Leonardi Cattolica
RCRoberto Cini
Roberto Cini
MSMassimo Santini
Massimo Santini
Y- graft (Y-G) is a graft formed by the Left Internal Mammary Artery (LIMA) connected to the Left Anterior Descending Artery (LAD) and by a free Right Internal Mammary Artery (RIMA) connected to LIMA and to a Marginal artery of Left Circumflex Artery (LCx). Aim of the work was to study the flow of this graft during a six months follow-up to assess whether the graft was able to meet the request of all the left coronary circulation, and to assess whether it could be done by evaluation of coronary flow reserve (CFR).