Meredith Hubbard

Meredith Hubbard

Auto-generated profile, based on publicly available information

Meredith Hubbard

Department of Neurobiology, The University of Alabama at Birmingham, School of Medicine

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Experimental Eye Research
Verified
Journal Article
Closed access
MFMassimo a Fazio
Massimo a Fazio
SGStuart K. Gardiner
Stuart K. Gardiner
LBLuigi Bruno
Luigi Bruno
MHMeredith Hubbard
Meredith Hubbard
GBGianfranco Bianco
Gianfranco Bianco
CGChristopher A. Girkin
Christopher A. Girkin

27 June 2022 in medRxiv
Verified
Preprint
Open access
PDF file
MFMassimo a Fazio
Massimo a Fazio
GBGianfranco Bianco
Gianfranco Bianco
UKUdayakumar Karuppanan
Udayakumar Karuppanan
MHMeredith Hubbard
Meredith Hubbard
LBLuigi Bruno
Luigi Bruno
CGChristopher Girkin
Christopher Girkin
To quantify the effect of negative pressure applied to the anterior surface of the eye on absolute IOP. Subjects Participants, and/or Controls. Three eyes from three research-consented brain-dead organ donors. Methods Air-tight goggles connected to a negative pressure (NP) pump (Mercury Multi-pressure Dial (MPD); Equinox Ophthalmic, Inc., CA) were tested on three research consented brain-dead organ donors. The MPD was set to generate a vacuum of -20mmHg. A baseline IOP of 10, 20, and 30mmHg was sequentially set by adjusting the height of a balanced salt solution bottle connected to the cornea through a 20G needle. IOP was manually annotated at time = 0s, right before turning on the vacuum pump; after a few seconds with the vacuum pump ON; at 60s; at 120s, right before turning the pump OFF; at 240s with the pump OFF (recovery). Three repetitions per each test at varying baseline IOP were taken for a total of nine series of measures per eye. Main Outcome Measures IOP change with exposure to NP. Results Eye1 and 3 showed an immediate reduction in IOP at all baselines immediately following activation of the MPD NP pump; Eye2 showed an opposite response to NP. Eye1 and 3 showed a reduction in IOP at all baselines with NP pump ON for 60s and 120s, while Eye 2 showed a consistent increase in IOP. After 120s from turning NP OFF (time=240s), IOP partially recovered to its baseline in all eyes. Conclusions This study is the first to evaluate changes in manometrically-measured intracameral IOP due to NP applied to the ocular surface in living conditions. The inconsistent response of IOP following exposure to negative pressure warrants further investigations on the mechanism underlaying IOP lowering by NP.