A new type of sphincterotome released to the market recently has high rotation performance and a freely bendable blade. It is devised to be singly capable of accommodating not only normal anatomy but also cases with surgically altered anatomy. This study was undertaken for clinical evaluation of the usefulness of this new sphincterotome. Eight cases in a reconstructed intestine for which cannulation or endoscopic sphincterotomy (EST) had been performed were extracted from 32 cases for which endoscopic retrograde cholangiopancreatography‐related procedures were performed using the sphincterotome developed during November 2023 through February 2024. The cases were investigated retrospectively. Among these, EST was applied to six cases. Cannulation was performed using the developed sphincterotome in the native papilla in four cases. The primary endpoints were the success rate of cannulation in surgically altered anatomy and the success rate of EST. Secondary endpoints were complications and usability for operators. Usability for operators was evaluated by questionnaire for several items on a 5‐point scale. EST was conducted successfully in all six cases subjected to EST. Mild hemorrhage was observed in one case (17%) as an adverse event after EST. Deep cannulation to the native papilla with the developed sphincterotome was conducted successfully in three cases (75.0%). Evaluation results by operators were 4.4 ± 0.55 for rotation performance, 4.00 ± 0.63 for incision performance, 4.29 ± 0.49 for deep cannulation performance, and 4.07 ± 0.19 for overall evaluation. In conclusion, this developed sphincterotome might be very useful for EST and cannulation in cases with surgically altered anatomy.
Endoscopic ultrasound (EUS)‐guided coil deployment (EUS‐coiling) has been newly developed for treating isolated gastric varices (iGV). This report describes three cases of EUS‐coiling for iGV using a 0.035‐inch hydrocoil (Azur; Terumo Corp., Tokyo, Japan). When used for EUS‐coiling, this hydrocoil provides the following benefits: Its electrically detachable system allows pull back. It has smooth and dense deployment. Moreover, it has a strong blood‐flow blocking effect because of its long length and large diameter with internal swelling functions of the hydrogel. Technical success of coiling was achieved in all cases. After coiling, additional treatments such as cyanoacrylate and sclerosant injection were performed as deemed appropriate. All iGVs were obliterated successfully. No adverse event occurred during the procedure or during the mean follow‐up of six months. Our findings indicate that this 0.035‐inch hydrocoil can be used to treat iGV safely and effectively.