Youngbin Tchoe

Youngbin Tchoe

Auto-generated profile, based on publicly available information

Youngbin Tchoe

Integrated Electronics and Biointerfaces Laboratory, Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2022 in Science Translational Medicine
Verified
Journal Article
Closed access
YTYoungbin Tchoe
Youngbin Tchoe
ABAndrew M. Bourhis
Andrew M. Bourhis
DCDaniel R. Cleary
Daniel R. Cleary
BSBrittany Stedelin
Brittany Stedelin
JLJihwan Lee
Jihwan Lee
SDShadi A. Dayeh
Shadi A. Dayeh
Electrophysiological devices are critical for mapping eloquent and diseased brain regions and for therapeutic neuromodulation in clinical settings and are extensively used for research in brain-machine interfaces. However, the existing clinical and experimental devices are often limited in either spatial resolution or cortical coverage. Here, we developed scalable manufacturing processes with a dense electrical connection scheme to achieve reconfigurable thin-film, multithousand-channel neurophysiological recording grids using platinum nanorods (PtNRGrids). With PtNRGrids, we have achieved a multithousand-channel array of small (30 μm) contacts with low impedance, providing high spatial and temporal resolution over a large cortical area. We demonstrated that PtNRGrids can resolve submillimeter functional organization of the barrel cortex in anesthetized rats that captured the tissue structure. In the clinical setting, PtNRGrids resolved fine, complex temporal dynamics from the cortical surface in an awake human patient performing grasping tasks. In addition, the PtNRGrids identified the spatial spread and dynamics of epileptic discharges in a patient undergoing epilepsy surgery at 1-mm spatial resolution, including activity induced by direct electrical stimulation. Collectively, these findings demonstrated the power of the PtNRGrids to transform clinical mapping and research with brain-machine interfaces.

15 November 2021 in Applied Physics Reviews
Verified
Journal Article
Closed access
PDF file
YTYoungbin Tchoe
Youngbin Tchoe
JLJihwan Lee
Jihwan Lee
RLRen Liu
Ren Liu
ABAndrew M. Bourhis
Andrew M. Bourhis
RVRitwik Vatsyayan
Ritwik Vatsyayan
SDShadi A. Dayeh
Shadi A. Dayeh
Nanoscale interfaces with biological tissue, principally made with nanowires (NWs), are envisioned as minimally destructive to the tissue and as scalable tools to directly transduce the electrochemical activity of a neuron at its finest resolution. This review lays the foundations for understanding the material and device considerations required to interrogate neuronal activity at the nanoscale. We first discuss the electrochemical nanoelectrode-neuron interfaces and then present new results concerning the electrochemical impedance and charge injection capacities of millimeter, micrometer, and nanometer scale wires with Pt, PEDOT:PSS, Si, Ti, ITO, IrOx, Ag, and AgCl materials. Using established circuit models for NW-neuron interfaces, we discuss the impact of having multiple NWs interfacing with a single neuron on the amplitude and temporal characteristics of the recorded potentials. We review state of the art advances in nanoelectrode-neuron interfaces, the standard control experiments to investigate their electrophysiological behavior, and present recent high fidelity recordings of intracellular potentials obtained with ultrasharp NWs developed in our laboratory that naturally permeate neuronal cell bodies. Recordings from arrays and individually addressable electrically shorted NWs are presented, and the long-term stability of intracellular recording is discussed and put in the context of established techniques. Finally, a perspective on future research directions and applications is presented.

28 September 2022 in Science Translational Medicine
Verified
Journal Article
Closed access
SRSamantha M. Russman
Samantha M. Russman
DCDaniel R. Cleary
Daniel R. Cleary
YTYoungbin Tchoe
Youngbin Tchoe
ABAndrew M. Bourhis
Andrew M. Bourhis
BSBrittany Stedelin
Brittany Stedelin
SDShadi A. Dayeh
Shadi A. Dayeh
Intraoperative neuromonitoring (IONM) is a widely used practice in spine surgery for early detection and minimization of neurological injury. IONM is most commonly conducted by indirectly recording motor and somatosensory evoked potentials from either muscles or the scalp, which requires large-amplitude electrical stimulation and provides limited spatiotemporal information. IONM may inform of inadvertent events during neurosurgery after they occur, but it does not guide safe surgical procedures when the anatomy of the diseased spinal cord is distorted. To overcome these limitations and to increase our understanding of human spinal cord neurophysiology, we applied a microelectrode array with hundreds of channels to the exposed spinal cord during surgery and resolved spatiotemporal dynamics with high definition. We used this method to construct two-dimensional maps of responsive channels and define with submillimeter precision the electrophysiological midline of the spinal cord. The high sensitivity of our microelectrode array allowed us to record both epidural and subdural responses at stimulation currents that are well below those used clinically and to resolve postoperative evoked potentials when IONM could not. Together, these advances highlight the potential of our microelectrode arrays to capture previously unexplored spinal cord neural activity and its spatiotemporal dynamics at high resolution, offering better electrophysiological markers that can transform IONM.

24 April 2024 in Science Translational Medicine
Verified
Journal Article
Closed access
YTYoungbin Tchoe
Youngbin Tchoe
TWTianhai Wu
Tianhai Wu
HUHoi Sang U
Hoi Sang U
DRDavid M. Roth
David M. Roth
DKDongwoo Kim
Dongwoo Kim
SDShadi A. Dayeh
Shadi A. Dayeh
Functional mapping during brain surgery is applied to define brain areas that control critical functions and cannot be removed. Currently, these procedures rely on verbal interactions between the neurosurgeon and electrophysiologist, which can be time-consuming. In addition, the electrode grids that are used to measure brain activity and to identify the boundaries of pathological versus functional brain regions have low resolution and limited conformity to the brain surface. Here, we present the development of an intracranial electroencephalogram (iEEG)–microdisplay that consists of freestanding arrays of 2048 GaN light-emitting diodes laminated on the back of micro-electrocorticography electrode grids. With a series of proof-of-concept experiments in rats and pigs, we demonstrate that these iEEG-microdisplays allowed us to perform real-time iEEG recordings and display cortical activities by spatially corresponding light patterns on the surface of the brain in the surgical field. Furthermore, iEEG-microdisplays allowed us to identify and display cortical landmarks and pathological activities from rat and pig models. Using a dual-color iEEG-microdisplay, we demonstrated coregistration of the functional cortical boundaries with one color and displayed the evolution of electrical potentials associated with epileptiform activity with another color. The iEEG-microdisplay holds promise to facilitate monitoring of pathological brain activity in clinical settings.

20 February 2026 in Biomedical Engineering Letters
Verified
Journal Article
Open access
PDF file
MHMinseong Hong
Minseong Hong
YYYeongSeok Ye
YeongSeok Ye
JKJoungwon Kim
Joungwon Kim
JKJae-Ick Kim
Jae-Ick Kim
JRJong-Cheol Rah
Jong-Cheol Rah
YTYoungbin Tchoe
Youngbin Tchoe
Neural interface technologies stand at the threshold of a revolution, offering new possibilities for seamless, high-bandwidth interconnection between the human brain and computers. Recent progress has been driven by advances in microscale manufacturing, yielding sophisticated neural probes with diverse form factors capable of recording from macroscopic networks down to single units. These platforms span rigid-to-soft architectures and combine inorganic and organic materials, improving compatibility with the brain’s mechanical and chemical properties. Despite these advances, the field still relies primarily on nonbiological electrodes, which face inherent limitations in adapting to the dynamic and complex nature of living neural tissue. Living biomaterials-integrated neuroelectronics, on the other hand, could open new possibilities by enabling technologies that adapt to the host environment, actively establish bidirectional interfaces, conform to living tissue, and support repair by leveraging the inherent regenerative and plastic capacities of living systems. This review provides an overview of recent progress, challenges, and emerging directions in the integration of living biomaterials with neuroelectronic systems. We frame biohybrid neural interfaces as the convergence of in vitro microelectrode arrays and in vivo brain interfaces and organize the review around three themes: (i) cell sources for device integration, (ii) advances in in vitro MEA platforms, and (iii) cell-integrated, living electrodes for in vivo neural interfacing. Considered jointly, the themes point to an integrated path to seamless, adaptive biohybrid neural interfaces.

10 July 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
JWJun Wang
Jun Wang
RLRen Liu
Ren Liu
YTYoungbin Tchoe
Youngbin Tchoe
ABAlessio Paolo Buccino
Alessio Paolo Buccino
APAkshay Paul
Akshay Paul
GCGert Cauwenberghs
Gert Cauwenberghs
Intracellular electrophysiology, a vital and versatile technique in cellular neuroscience, is typically conducted using the patch-clamp method. Despite its effectiveness, this method poses challenges due to its complexity and low throughput. The pursuit of multi-channel parallel neural intracellular recording has been a long-standing goal, yet achieving reliable and consistent scaling has been elusive because of several technological barriers. In this work, we introduce a micropower integrated circuit, optimized for scalable, high-throughput in vitro intrinsically intracellular electrophysiology. This system is capable of simultaneous recording and stimulation, implementing all essential functions such as signal amplification, acquisition, and control, with a direct interface to electrodes integrated on the chip. The electrophysiology system-on-chip (eSoC), fabricated in 180nm CMOS, measures 2.236 mm × 2.236 mm. It contains four 8 × 8 arrays of nanowire electrodes, each with a 50 μm pitch, placed over the top-metal layer on the chip surface, totaling 256 channels. Each channel has a power consumption of 0.47 μW, suitable for current stimulation and voltage recording, and covers 80 dB adjustable range at a sampling rate of 25 kHz. Experimental recordings with the eSoC from cultured neurons in vitro validate its functionality in accurately resolving chemically induced multi-unit intracellular electrical activity.