4 June 2015 in Geophysical Journal International
Wells and boreholes are routinely steel-cased in oil and gas fields and geological storage sites. There have been a number of studies on the effects of a steel-cased well on various electrical and electromagnetic (EM) geophysical methods. In this paper, we examine the use of a steel-cased well as a virtual vertical electric source for sensing deep localized resistive (e.g. CO2, oil and gas) and conductive (e.g. conductive-proppant-filled fractures) targets when concentric electric sources are grounded around the collar of the well. To simulate the casing effects, we present a 3-D finite-element time-domain (FETD) algorithm with tetrahedral elements. The FETD algorithm is designed to reduce memory usage in adaptive time stepping by utilizing parallel direct and iterative solvers appropriately together. To avoid a larger number of tiny elements required for discretizing a thin wall of the casing, the hollow casing is approximated with a rectangular prism. By not discretizing the thin wall of and the curvature of the round casing, the approximation not only reduces the number of unknowns by an order of magnitude but also improves overall mesh qualities. We show that surface EM responses over the hollow casing and the prism are practically the same. Through FETD modelling of a rectangular prism as an approximation of a steel casing, we demonstrate that a steel casing can serve as a conduit through which a high concentration of electrical currents can flow downward from the surface, interact with deep localized reservoirs/fractures and produce a measurable perturbation in the surface EM fields. Concentric electric sources can further improve both the sensitivity to the deep targets and the overall magnitude of surface EM fields.
12 March 2013 in Geophysical Journal International
We formulate a 3-D finite-element frequency-domain (FEFD) solution for electromagnetic (EM) diffusion and present efficient solution strategies. A system of FEFD equations is pre-conditioned by incomplete LU (ILU) and subsequently solved by the quasi-minimal residual (QMR) method. A rule of thumb for choosing an effective drop tolerance of ILU is proposed. When multiple sources are simulated in a given model, ILU is computed only once and is reused as a pre-conditioner for multiple QMR computations with different source vectors. Resulting solution vectors are also bootstrapped to reduce the number of QMR iterations required for the convergence. We demonstrate that when conductivity structures of an earth model and source frequencies are updated/perturbed, ILU that is computed from the previous model is still an effective and useful pre-conditioner for new forward modelling problems. Using the reusability of ILU, we also propose a new efficient way to overcome the slow convergence rate of the iterative FEFD solution in the static limit. We show that the reuse of ILU and solution bootstrapping serve as effective strategies for improving the computational efficiency of the iterative FEFD solution. Finally, we apply the proposed efficient solution strategies to marine EM survey scenarios in complex offshore models and further demonstrate their effectiveness.
6 June 2012 in Geophysical Journal International
Summary. An iterative finite element time-domain (FETD) method has been developed for simulating transient electromagnetic fields in 3-D diffusive earth media
6 July 2020 in Geophysics
The borehole-to-surface electromagnetic (EM) method is a viable imaging and monitoring tool for energy reservoirs, geologic storage, geothermal exploration, fault zones, and other subsurface targets. Data interpretation typically requires considering steel-casing effects, but it is difficult and impractical to directly discretize arbitrarily oriented hollow steel-cased wells in a 3D reservoir-scale earth model because of their extremely high electrical conductivity and long hollow geometry. We have considered a borehole-to-surface EM configuration in which an electric dipole source is placed below the bottom of a steel-cased well. To practically simulate the casing effects on EM measurements, we develop a novel 3D finite-element EM algorithm using an unstructured tetrahedral mesh. To avoid excessive use of fine grids for modeling a steel-cased well, the well is replaced with the combination of a short solid conductive prism and a long linewise perfect electric conductor. We find that this combined structure can approximate casing effects at a small fraction of the computational cost required for modeling a complete hollow casing because the linewise structure is volumeless and does not require an excessive number of small elements. We also find that steel-cased wells distant from sources and receivers can be modeled as simple linewise perfect electric conductors, further improving the computational efficiency. Using this approximation, the 3D EM algorithm presented here is well-suited to modeling many arbitrarily oriented steel-cased wells. After verifying the accuracy and efficiency of this approach using various examples, we performed a 3D borehole-to-surface/surface-to-borehole and surface EM inversion and determine that the inversion can image a deep localized target in the presence of steel infrastructure.
18 November 2019 in Geophysics
Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage, and hazardous waste disposal. We have developed a simple noninvasive technology for casing integrity screening, based on the continuity of electrical current flow. Applying low-frequency current to a wellhead, with a distant return electrode, produces a casing current dependent on the background formation and the properties and depth extent of the well casing. These currents in turn generate surface electrical fields that can be captured in a radial profile and can be used to analyze properties of the well casing. Numerical modeling results reveal a strong relation of the electric field to the casing properties and depth extent of the well. A small breakage in the casing produces a profile coincident to a cased well with a completion depth above the break. A corroded patch, in which the casing conductivity is reduced, also alters the field profiles, and its depth may be estimated by comparing to the profile expected from the well completion diagrams. The electric field profiles are also strongly dependent on background resistivity distributions and on whether the well was drilled using water- or oil-based drilling fluids. We validate the proof of concept in a field experiment, in which we apply currents at the wellheads of two adjacent wells with different casing lengths in an area of known background resistivity. The two profiles are similar in appearance but are offset in amplitude by more than a factor of five, consistent with the theoretical analysis and the 3D modeling results. These results demonstrate that our approach has promise for mapping the general casing condition without well intervention. This approach can be a practical and effective tool for rapidly screening several wells before expensive logging-based technologies are used for casing inspection in detail.
13 December 2018 in Geophysics
Imaging hydraulically active fracture zones (HAFZ) is of paramount importance to subsurface resource extraction, geologic storage, and hazardous waste disposal. We have developed advanced 3D finite-element (FE) electrical imaging algorithms for HAFZ in the presence of a steel-cased well. The algorithms use tetrahedral FE meshes in the simulation domain and coarse rectangular finite-difference meshes in the imaging domain. This heterogeneous dual-mesh approach is well suited to modeling the multiscale earth model due to steel-cased wells. We find that the algorithms accurately and efficiently simulate surface electric field measurements over a 3D HAFZ at depth when one end point of a surface electric source is connected to a wellhead. For brevity, this configuration is called the top-casing electric source method. By replacing a hollow cased well with a solid prism, we improve our computational efficiency without affecting the solution accuracy. The sensitivity of the top-casing source method to HAFZ highly depends on the continuity of a steel-cased well because it makes currents preferentially flow to HAFZ. The sensitivity also depends on conductivity structures around the well because they control current leaking from the steel-cased well. We find that the method can image a localized HAFZ and detect changes in its width and height. The imaging results are improved when a volume of the imaging domain is constrained from geomechanical perspectives. A primary advantage of the method is the fact that the sources and receivers are placed on the surface, thus not interrupting the well operation.